Oscilloscope, multimeter S1-107 (S1107, S-1-107, S 1107, S1-107, S 1107, S1 107, c1107, c-1-107, c 1107, c 1107, c1 107)
 
Oscilloscope, multimeter S1-107 is:
- To study the form of electrical signals in the frequency range of 5MHz to 0MGts by visual observation and measurement of their amplitudes in the range from 0.02 V to 120 V (with external divider 1:10 to 350V) and the time intervals of 0,4 ∙ 10 -6 s to 1.0 s in the oscilloscope mode;
- To measure the DC voltage of 1 ∙ 10 -3 V to 1000V, AC 1 ∙ 10 -3 g of 300V DC power from 1 ∙ 10 -6 A to 1.999 A, the activity of the resistivity in the range of 1 ∙ 10 -3 ohm-1999 ohms in the mode of a multimeter.
The device is an oscilloscope, multimeter S1-107 is performed in two ways:
- Table - drawing designation I22.044.088-01;
- To work in field conditions - symbol drawing N22.044.088.
 
Technical characteristics of the devices, multimeters oscilloscope S1-107:
 
The working climate the device are:
- Ambient temperature - from -30 ° C to +30 ° C;
- Relative humidity - up to 98% at +35 ° C;
- Atmospheric pressure - from 60kPa to 104kPa (from 460 mm. Hg. Art. 780 mm. Hg. Art.);
The working part of the device screen oscilloscope, multimeter S1-107:
- 60mm (10 divisions, the price of division 6 mm) horizontal;
- 40 mm (6 and 2 / 3 divisions, the price of division 6 mm) vertically;
The line width of the beam oscilloscope Multimeter instrument S1-107 - less than 0.8 mm;
The basic error of the calibrated coefficients of vertical deviation (0.01 V / div, 0.02 V / div, 0.05 V / div and 0.1 V / div and 0.2 V / div and 0.5 V / div; 1V/del, 2B / Affairs; 5V/del; 10V/del; 20V/del) - no more than 8%;
The error coefficient of variation instrumentoscilloscope, multimeter S1-107 in the range of influence quantity - no more than 12%;
Coefficient of variation is adjustable with an overlap of at least 2.5-fold;
Step response time channel oscilloscope vertical deflection device- S1-107 multimeter with direct input with the remote and 1:10 divider - not more than 70ns;
Emission characteristics of a transitional path in vertical position with the direct input and with external divider 1:10 - no more than 5%;
The time for establishing the transition channel performance in vertical position with the direct input and with external divider 1:10 - no more than 210ns;
The uneven top of the unit step response oscilloscope, multimeter S1-107 - less than 3%;
The decline of the transient characteristic peaks of the test pulse of 10 ms with a closed input - no more than 10%;
The bandwidth of the vertical deflection channel oscilloscope Multimeter instrument S1-107 - from 0MGts to 5 MHz;
The uneven frequency response in the normal frequency range of 1MHz-0MGts - no more than 8% compared to the reference frequency of 1 kHz;
The drift of the line scan path vertical deflection after the time of an operating mode - no more than:
- Short - 1 mV;
- Long term - 5mV / h;
The displacement of the beam oscilloscope Multimeter instrument S1-107 due to the input current - not more than 5mV;
H a scanning line can be observed both synchronous and unsynchronized interferences from the mains frequency, transmitter and other noises.Their magnitude should not exceed 1 mV (0.1 division) and is defined as the maximum deflection of the beam (or the release of Padina) from a horizontal line;
Limits of movement in the vertical beam - at least two values ​​of the nominal vertical deflection;
Parameters of vertical deflection of the instrument channel oscilloscope, multimeter S1-107:
- Input resistance - 1 MW ± 0,02 MW in parallel with 35pF ± 5pF with direct inlet;
- Input resistance - 1 MW ± 0,02 MW in parallel with no more than 13pF with an external divider 1:10;
Restricted to the total value of the DC and AC voltage device oscilloscope, multimeter S1-107 at the closed entrance channel vertical deflection no more than:
- 200V by direct inlet;
- 350V with external divider 1:10;
The delay in the path of the image signal is the vertical deflection device oscilloscope Multimeter S1-107 provides a view of the front of the signal on the working part of the sweep;
Footnote. Working part sweep is 10 divisions stretch from the beginning of the exception to the initial section of length 0.2 cases;
Sweep generator provides the following modes of operation of the device oscilloscope, multimeter S1-107:
- Self-oscillation;
- Waiting.
The basic error of the calibrated sweep (0.1 microseconds / div, 0.2 ms / div, 0.5 ms / div; 1mks/del; 2mks/del; 5mks/del; 10mks/del; 20mks/del; 50mks/del; 100mks / Affairs; 200mks/del; 500mks/del, 1 ∙ 10 3 ms / div, 2 ∙ 10 3 ms / div, 5 ∙ 10 3 ms / div, 1 ∙ 10 4 microseconds / div, 2 ∙ 10 4 microseconds / div; 5 ∙ April 10 ms / div, 1 ∙ 10 5 ms / div) - no more than 8%;
Accuracy of calibrated sweep in the range of influence quantity - no more than 12%;
Duration of scanning device oscilloscope, multimeter S1-107 is adjustable for each band with an overlap of at least 2.5-fold;
Limits movement of the beam in the horizontal alignment should provide the beginning and end of the working part of the sweep center of the screen;
Coefficient of variation channel horizontal deflection - no more 1V/del;
The input resistance of the entrance channel horizontal deflection - not less than 30 ohms in parallel with no more than 30pF;
Internal synchronization device oscilloscope, multimeter S1-107 by sinusoidal signals in the frequency range from 1 Hz to 5 ∙ 10 6 Hz and pulse duration of both polarities from 0.3 s to 1 ∙ 10 6 microseconds;
The height of the image from a minimum value equal to no more than 0.6 division in the range of 1 Hz to 1 ∙ 10 6 Hz and 1 division to 5 ∙ 10 6 Hz to a maximum of 6 divisions;
Instability start scanning device oscilloscope, multimeter S1-107 - less than 10 ns;
In the oscillatory regime sweep the lower frequency sweep run no more than 100 Hz;
External clock sweep by sinusoidal signals in the frequency range from 1 Hz to 5 ∙ 10 6 Hz and pulse signals of both polarities duration from 0.3 s to 1 ∙ 10 6 microseconds with an amplitude of 0.5 V to 50 V;
Instability start scanning - no more than 10 ns;
In the oscillatory regime sweep the lower frequency sweep run - less than 100 Hz;
Options Genlock input device oscilloscope, multimeter S1-107 (open):
- Input resistance nests "0.5-5" - no less than 30 ohms in parallel with no more than 30pF;
- Input resistance nests "5-50" - not less than 650 ohms in parallel with no more than 10 pF;
The internal voltage source generates a calibrated U-shaped pulses with a repetition rate of 1 kHz and an amplitude of 1 V;
The main error of the amplitude and pulse frequency oscilloscope calibrator instrument meter- S1-107 - less than 2%;
Accuracy of the amplitude and pulse frequency of the calibrator in the range of influence quantity - less than 3%;
Geometric distortion - less than 3%;
 
Meter Mode
 
The choice of type and extent of the measurement instrument oscilloscope, multimeter S1-107 is performed manually by a switch type of work («R, -, ~») and a pen full scale (combined with an attenuator knob);
When measuring voltage or DC power, determination and polarity indication is done automatically;
In the measurement of electrical quantities, whose values ​​exceed the final value of the selected limit is indicated by the sign "P";
Indication of commas, depending on the position of the switch device limit oscilloscope, multimeter S1-107 corresponds to Table 1;
 
Table 1
Switch position full scale
Point position
0.2
, 0000
"2"
0.000
{0}{1}20%{/1}{/0}
- 00 00
200
000.0
2000
0000
 
Measuring range of DC voltage 1 ∙ 10 -3 V-1000 V, is divided into sub-bands, "0.2", "2", "20", "200", "2000";
Measuring range AC 1 ∙ 10 -3 V-300B, is divided into sub-bands, "0.2", "2", "20", "200", "2000";
When measuring the AC unit oscilloscope, multimeter S1-107 retains its essential characteristics after exposure to handling stress in 1 minute:
- 10 times the limit of "0.2", "2", "20";
- 5 times the limit of "200";
- 1.1-fold at the limit of "2000";
Range of measuring the strength of the DC 1 ∙ 10 -6 A-1, 999A is divided into sub-bands, "0.2", "2", "20", "200", "2000";
When measuring DC power unit oscilloscope, multimeter S1-107 retain their essential characteristics of the limits established by TU, after exposure to handling current for 1 minute:
- 10 times - at the limits of "0.2", "2", "20";
- 1.2-fold - to the limit of "200";
- 1.1-fold - to the limit of "2000";
Resistance measurement range 1 ∙ 10 -3 ohm ohm-1999 is divided into sub-bands, "0.2", "2", "20", "200", "2000";
The input resistance of the device oscilloscope, multimeter S1-107 in the measurement of DC and AC power is not less than 10 MW;
Input capacity - up to 100 pF;
Average Power in the measured resistance - less than 1 mW;
 
General data of the instrument oscilloscope, multimeter C1-107
 
Adjusting the brightness of the image brightness changes ensures the total absence to a convenient for observation;
Electrical isolation between the input power supply circuit network cable and the housing unit ^ withstand without breakdown withstand voltage AC, 50 Hz, the effective value of which corresponds to:
- 1500V in normal conditions;
- 900V in wet conditions;
Operation mode setup time oscilloscope Multimeter instrument S1-107 - less than 5 minutes;
Allowed continuous operation of the oscilloscope, multimeter in working conditions within 16 hours;
The device is an oscilloscope, multimeter S1-107 is powered by:
a) AC 220V ± 22V 50Hz ± 0,5 Hz and 60 Hz ± 0,5 Hz and harmonic content up to 5%;
b) AC voltage 115 V ± 5,5 V and 220 V ± 11 V with a frequency of 400 Hz ± 12Gts and harmonic content up to 10%;
c) DC voltage of 27V ± 2,7 V;
The power consumed by the device oscilloscope S1-107 multimeter on AC, with rated voltage not more than 25 V ∙ A;
The current consumed by the DC current at a voltage of 27 V must not exceed 0.6 A;
Working hours instrument oscilloscope Multimeter S1-107 waiver - 1500 hours;
Average life - at least 10 years of age;
Average life - 10,000 hours;
Overall dimensions oscilloscope, multimeters S1-107 - 245X111X360mm;
Dimensions of laying the box - no more 530X246X302mm;
Dimensions of container box - no more 729X369X443mm;
Weight of the device - no more than 4 kg;
Weight with box - no more than 4.5 kg;
The mass of the oscilloscope, multimeter laying box - no more than 15kg;
Unit weight oscilloscope, multimeter S1-107 to transport container and laying box - no more than 35kg;
Weight of the device with transport container and with the box - no more than 25kg.