Radiometric devices >> uniformity tester of cables and lines

R5-24

For order is possible effectively delivery of any quantity.

Meter irregularities lines R5-24

Also, this device can be called: R524, R5 24, r5-24, r524, r5 24.

R5-24 meter irregularities lines used for:

- Conducting basic measurements on long cables (coaxial, power, communications, etc.) up to 100 km;

- Discovery of the damage and determine its nature (open circuit, short circuit, leakage, contact failure, insert, etc.);

- Determine the distance to the fault or irregularity.

Specifications R5-24:

Distance measuring ranges:

- From 0 km to 0,03 km;

- From 0 km to 0,1 km;

- From 0 km to 0,3 km;

- From 0 km to 1 km;

- From 0 km to 3 km;

- From 0 km to 10 km;

- From 0 km to 30 km;

- From 0 km to 100 km.

Basic measurement error distance:

- At a range of 30 km to 100 km - 0,3%;

- At a range of 30 m to 100 m - 1%.

Setting limits on the velocity factor meters - from 1 to 7.

Minimum measuring distance (at y = 1,5 K) - 1 m.

Probe pulse duration - 10 ns to 10 ms.

The amplitude of the probe pulse R5-24 to 50 Ohm load:

- Duration to 50 ns - 2,5 V;

- Duration of 50 ns - 3,5 V to 30 V.

Remembering the internal nonvolatile memory - at least 100 traces.

Overlapped attenuation - 80 dB.

Range Output Impedance - 30 Ohm to 470 Ohm.

External port - RS-232 C.

Time of continuous battery life - 2 hours.

Dimensions - 315×180×60 mm.

Mass meter with power supply - 1,9 kg.

Operating conditions R5-24:

Ambient temperature - from -20º C to +50º C.

Relative humidity at 25° C - 98%.

Power meters:

- AC - 220 V, 50 Hz;

- Maximum power consumption - 22 V·A;

- From DC - 10 A to 18 A;

- Maximum power R5-24 - 12 W;

- From an independent source - Nicd (NiMh) batteries 4hAA 2000 mAh (mAh).

Photos: R5-24

R5-24 device image.
R5-24 device image.


Яндекс цитирования