Radiometric devices >> other meters

PO-1

99 999 RUB
40 000 UAH
available:
4 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Power flux density meter PO-1

Also this device can be called: PO1, PO 1, P0-1, P-01, P 01.

 

PO-1 meter power flux density is used to measure the flux density of the radiation power UHF-SHF.

The composition of the meter PO-1 includes an antenna, battery pack, matching attenuator D2-9, the bridge to measure the power on thermistors M4-2, matched load E9-9.

 

Meters PO-1 is also equipped with a set of horn antennas (P6-17, P6-19, P6-20) and thermistor heads (M5-17, M5-19, M5-21, M5-22).

 

Specifications PO-1:

 

Operating frequency range - from 150 MHz to 10 GHz.

Range measurements M4-2 - from 0 to 150 mcW; from 0 to 500 mcW; from 0 to 5 mW, from 0 to 7,5 mW.

 

Wavelength:

- M5-17 - from 200 cm to 10 cm;

- M5-19 - from 3.6 cm to 5,4 cm;

- M5-21 - from 2.1 cm to 2,6 cm;

- M5-22 - from 1.8 cm to 2,1 cm.

 

Parameters D2-9:

- frequency range - from 0,15 GHz to 2,7 GHz;

- VSWR - 1,5;

- power - 1W.

 

The wavelength of the fundamental radiation of the antenna:

- P6-17 - from 5,4 cm to 3,6 cm;

- P6-19 - from 11,1 cm to 8 cm;

- P6-20 - from 16,7 cm to 11 cm

 

E9-9 is a load resistance, absorbing power supplied to it.

Operating frequency range E9-9 - from 30 MHz to 1000 MHz.

 

Attenuation, insertion feeder and matching attenuator advance taken into account in the design PO-1. Measuring the flux density necessary to produce power at a maximum operating capacity of the emitting device with reduced or several times followed by multiplication of the measured power flux density in n times.

Photos: PO-1

M4-2 bridge to the flow meter power PO-1.
M4-2 bridge to the flow meter power PO-1.
Battery pack to the power meter PO-1.
Battery pack to the power meter PO-1.
D2-9 to a set attenuator power meter PO-1.
D2-9 to a set attenuator power meter PO-1.
P6-17 meter antenna to the PO-1.
P6-17 meter antenna to the PO-1.
P6-19 antenna to the flow meter power PO-1.
P6-19 antenna to the flow meter power PO-1.
P6-20 antenna to the power meter PO-1.
P6-20 antenna to the power meter PO-1.
M5-17 head to the flow meter power PO-1.
M5-17 head to the flow meter power PO-1.
M5-19 head to the meter PO-1.
M5-19 head to the meter PO-1.
M5-21 head to a set of power meter PO-1.
M5-21 head to a set of power meter PO-1.
M5-22 head to the flow meter power PO-1.
M5-22 head to the flow meter power PO-1.
E9-9 load resistance to the meter PO-1.
E9-9 load resistance to the meter PO-1.
Antenna to the power meter PO-1.
Antenna to the power meter PO-1.


Яндекс цитирования