Radiometric devices >> oscilloscopes >> universal oscilloscope

N3015 Oscilloscope radio fancier N3015 (N 3015, N-3015)

N3015

9 999 RUB
4 000 UAH

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Oscilloscope radio fancier N3015 (N 3015, N-3015)
Designed for visual inspection of electrical processes, measuring time intervals, AC and DC voltages.
Dimensions of the working of the screen 30x40mm.
The channel provides a vertical deflection: the range of values ​​of the coefficient of deviation from 1x10 -3 to 20V/del.
Channel horizontal deflection provides a range of values ​​sweep of 0.04 × 10 -6 to 0.2 s / div.
Synchronization frequency range from 20 to 10x106Gts.

General instructions

Oscilloscope radio fancier N3015 are designed for visual observation of electrical processes, measuring time intervals, AC and DC voltages.

Operating conditions:
1. ambient temperature from 10 to 35 ° C;
2. relative humidity up to 80% at 25 ° C;
3. atmospheric pressure (84 - 106.7) kPa;
4. mains voltage (220 ± 22), line frequency (50 ± 1) Hz or (60 ± 1,2) Hz, with harmonic content of up to 5%.

Normal conditions of use:
1. ambient temperature (20 ± 5) ° C;
2. relative humidity (30-80)%;
3. atmospheric pressure (84 - 106.7) kPa;
4. mains voltage (220 ± 4,4) V ¬ ing frequency of the supply network (50 ± 1) Hz or (60 ± 1,2) Hz, at harmonic content of up to 5%.

Technical data

Oscilloscope ham N3015 provides simultaneous monitoring of two different signals by connecting a switch-type P323. Dimensions of the working of the screen 30x40 mm (7.5 divisions in the vertical and 10 horizontal divisions).

The line width of the beam does not exceed 0.7 mm. When set to "1" gain switch mV / div allowed beam width of 2 mm.
Vertical position of the channel provides:
the range of values ​​of the coefficient of deviation from 1x10 -3 to 20V/del;
Maximum permissible error of the instrument N3015 when measuring voltages on a grand scale from 5 mV to 150V no more than ± 12% at a frequency of 1 kHz;
frequency response with respect to the frequency of 1 kHz to 2 MHz frequency band up to no more than ± 12% in the frequency band above 2MHz to 10MHz to 40% - on the "x1000" input attenuator frequency response above 20kHz is not standardized;
Long-term drift of the beam up to 30 mV / h;
Input resistance is not less than 0.45 MΩ;
inbound capacity not exceeding 50 pF;
allowable total value of DC and AC voltagetion gated entrance not more than 500V, with maximum amplitude of the AC voltage 300V.

Channel horizontal deflection provides:
waiting and self-oscillating modes of scanning;
range of sweep from 0.04 × 10 -6 to 0.2 s / div;
Maximum permissible error of the instrument N3015 measurement of time intervals ranging from 2 ms to 2 with no more than ± 12%;
inner and outer sweep synchronization signals of positive and negative polarity and synchronization network;
synchronization frequency range from 20 to 10x106Gts;
External synchronization voltage sweep from 0.5 to 5V.

When measuring the voltage and time intervals, the limit of additional error N3015 appliance, rejecting the supply voltage of ± 10% of normal or ambient temperature deviations of ± 10 ° C from the normal value should be equal to half the value of the maximum permissible primary
error.
Power consumption 30 VA. Dimensions 285 x 85 x 315 mm. Unit weight N3015 no more than 4 kg. Information of precious materials in the device N3015: Gold - 0,123 g, silver - 0.89 g


Яндекс цитирования