Radiometric devices >> power meters

M5-41

4 099 RUB
3 279 UAH
available:
1 piece

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Primary measuring transducer M5-41 (M541, M5 41)
Primary measuring transducer M5-41 is designed to measure low-power microwave.
Used to measure the power supplied to the thermistor bridge, the regimes which ensure normal operation of the converter.
Supplied complete with M3-22A instrument or separately.

Technical characteristics of the devices measuring transducers primary M5-41:

Temperature - 243K 323K up (from -30 º C to +50 º C);
Relative humidity - 98% at 313K (40 º C);
Frequency band converter device measuring pulse M5-41 - 6.85 GHz, 9, 93GGts;
The cross section of the waveguide - 28,5 x12, 6mm;
Working resistance - 240 ohms;
KEF in the frequency range - 1;
Limit the relative error KEF - ± 5%;
Input VSWR measuring instrument transducer pulse M5-41 in the frequency range - less than 1.3;
Unlike current heating of the working and termokompensiruyuschey inserts in the range of operating temperatures (293 K provides a check at ± 5 K (20 º C ± 5 º C) - not more than 20%;
Care meter reading when checking the power converter device measuring pulse M5-41 in the absence of unstable resistances of the thermistor chains - ± 6mkVt;
The average value of zero care power meter at a constant ambient temperature for 30 seconds - less than 0.5 mW;
Maximum measured power converter device measuring pulse M5-41 - 10mW;
Power shift working and termokompensiruyuschey inserts:
- At a temperature of 243K ± 1 K (-30 º C ± 1 º C) - not more 70mVt;
- At a temperature of 323K ± 1 K (50 º C ± 1 º C) - at least 12mVt;
Sensitivity of the instrument measuring the pulse converter M5-41 - no less than 5 ohms / mW;
Maximum drift rate bias thermistor power meter with temperature compensation for ambient temperature shock - no more 2mkVt/min;
Impulse strength measuring instrument transducer pulse M5-41 - 25W;
KEF long-term instability in the 12 months of operation - no more than 6%;
Operation mode setup time measuring unit converter switching M5-41 thermistor when dealing with bridges:
- On the scales above 1 mW - 0.5 hours;
- At scales less than 1 mW - 2 hours;
Time of continuous operation of the device measuring pulse converter M5-41 in the work environment - 16 hours;
MTBF - 100,000 hours;
Dimension measuring instrument transducer pulse M5-41 - 110h47h54mm;
Weight - 0.4 kg.

Photos: M5-41

M5-41 primary image.
M5-41 primary image.
M5-41 storage box.
M5-41 storage box.
M5-41 delivery set.
M5-41 delivery set.
M5-41 delivery set.
M5-41 delivery set.
M5-41 front view.
M5-41 front view.
M5-41 side view №1.
M5-41 side view №1.
M5-41 side view №2.
M5-41 side view №2.
M5-41 side view №3.
M5-41 side view №3.
M5-41 side view №4.
M5-41 side view №4.
M5-41 rear view.
M5-41 rear view.


Яндекс цитирования