Radiometric devices >> power meters

M3-53 M3-53 wattmeter.

M3-53

83 999 RUB
29 400 UAH
available:
2 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Wattmeter M3-53 (M353, M-3-53, M 3 53, M3 53)
 
Wattmeter M3-53 is designed for high-precision power measurement of sinusoidal signals and the average power of pulse-modulated microwave signals in coax and waveguides.
 
Technical characteristics of the devices M3-53 wattmeters:
 
Frequency range - 0.02 GHz, 17, 85GGts;
Measurement range - 1mkVt-10mW (0.3 MW-3 MW-10mW);
Connection sizes RF input device power meter M3-53 (input impedance) - 7/3mm coax (50 ohm);
Permissible pulse power with pulse durations less than 10mks - 1W;
VSWR - 1.3 (0.02 GHz 12GGts), 1.4 (12GGts-17 85GGts);
Response time for all modes of operation of the device power meter M3-53 - 10c;
Frequency range - 25.86 GHz-37, 5GHz;
Measurement range - 1mkVt-10mW (0.3 MW-3 MW-10mW);
Connection sizes RF input device power meter M3-53 - a waveguide 7.2 x3, 4 mm;
Permissible pulse power - 1 W (m, not more than 10mks);
VSWR - no more than 1.4;
Response time for all modes of operation - 10s;
Frequency response unit wattmeter M3-53 absorbed power - 0GGts-17 85GGts;
Measurement range - 10-4-1W (0.03 W-0, 3W-1W)
Connection sizes RF input (input impedance) - 7/3mm coax (50 ohm);
Permissible pulse power device power meter M3-53 - 1.5 kW (maximum 10mks ty);
VSWR - 1.15 (0GGts-3 GHz), 1.3 (3GHz-12GGts), 1.4 (12GGts-17 85GGts);
Response time for all modes of operation - 20 s;
Frequency response unit wattmeter M3-53 - 0GGts-17 85GGts;
Measurement range - 0.01 W-20W (0.3W-3W-20W);
Connection sizes RF input (input impedance) - 7/3mm coax (50 ohm);
Permissible pulse power - 1.5 kW (m max 10mks);
VSWR - 1.15 (0GGts-3 GHz), 1.3 (3GHz-12GGts), 1.4 (12GGts-17 85GGts);
Response time for all modes of operation of the device power meter M3-53 - 10c;
Frequency range - 0GGts-3GHz;
Measurement range - 10-4-1W;
The main error of the instrument wattmeter M3-53 without error - no more than ± [6 0.1 (Rk/Rh-1)]%;
Characteristic Impedance - 75 ohms;
Section of the channel - 16X4, 6 mm;
VSWR - 1.2;
The main measurement error (δ) unit of the absorbed power wattmeter M3-53 (excluding mismatch error and the error of additional transitions) does not exceed the value calculated by the formulas:
- Δ = ± [0.1 4 (Rk/Rh-1)]% - 0GGts-12GGts;
- Δ = ± [6 0.1 (Rk/Rh-1)]% - 12GGts-37, 5GHz;
Each power meter consists of a measuring unit YA2M-66 and the remote receiver of microwave power converter;
Measuring unit with digital display has a high measurement accuracy and low drift zero;
The device is a power meter M3-53 has an output of the recorder and the MTC;
The principle of the watt meter is based on the conversion of microwave power in the form of thermal energy and measuring the output of the receiver formed on the thermoelectric converter;
Feature of the wattmeter is that while working for a long time there is no need for recalibration;
Control of the power meter devices M3-53 can be operated manually, semi-automatically and remotely;
Can be used in automated measurement systems;
The manufacturer guarantees the quality of the unit absorbed power wattmeter M3-53 technical requirements specifications, subject to the consumer the terms and conditions of storage, transportation, installation, operation, established specifications and operational documentation.


Яндекс цитирования