Radiometric devices >> power supplies, voltage stabilizers >> others power supplies, voltage stabilizers

LIPS-2-20

4 500 RUB
1 230 UAH
available:
2 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

    Power supply LIPS-2-20 (LIPS 2-20; LIPS2-20; LIPSII-20; LIPSII 20; LIPSII-20; LIPSII20)
    Source LIPS-2-20 - products intended to supply electronic circuits and devices stabilized DC voltage.

    Output voltage - 0 - 20V.
    Maximum load current: 2A.

    Specifications LIPS-2-20

    In the block functions are implemented self-blocking output voltage exceeds the overcurrent or short-circuit in the load with light, connect and disconnect the load after setting the output voltage, getting bipolar output voltage.
    Output terminals of the device LIPS-2-20, isolated from the hull, allowed ground plus or minus output voltage.
    The instability of the output voltage at the output terminals LIPS-2-20 in the control range 3-35V when the voltage of ± 10% of nominal for any permissible current load does not exceed ± 0,05%. The instability of the output voltage at the output terminals in a control range 3V - 35V when the load current to 1A should not exceed ± 0,15%.

    The temperature coefficient of output voltage Lips-2-20 in the control range 3B - 35B when the ambient temperature in the range 10 ° C - 35 ° C at a maximum permissible load current of 10 A does not exceed 0.1% C after warm-up time.
    The drift of the output voltage is 8 hours after 20 minutes of heating does not exceed 0.5% when the output voltage 3B - 35B.
    Power supply LIPS-2-20 provides a normal load voltage and current at 1 minute after the start, and the parameters of the output voltage within the rules after the time samoprogreva 20 minutes.

    LIPS-2-20 provides protection against current overload. Protection is triggered when the load current exceeds more than 10A. The device LIPS-2-20, provides protection circuit overvoltage output with adjustable set trigger voltage range 5V - 35V. Error protection operation when the load current in the range 0-10A does not exceed 2C.

    Switching on the instrument after protection from over-current and over-voltage is possible after the power is turned off LIPS-2-20, eliminating congestion.
    Dielectric strength output circuits - 250V DC. Insulation strength of input circuits - 1000V AC RMS value.
    Insulation resistance of these chains relative to the housing unit of at least 20MOm for normal conditions.
    Continuous working time 8:00 to the time samoprogreva. Warm-up time 20 minutes.
    The service life of LIPS-2-20 is at least 10 years of technical resources not less than 5000 hours.

Photos: LIPS-2-20

LIPS-2-20 device image.
LIPS-2-20 device image.
LIPS-2-20 front view.
LIPS-2-20 front view.
LIPS-2-20 side view.
LIPS-2-20 side view.
LIPS-2-20 rear view.
LIPS-2-20 rear view.
LIPS-2-20 overhead view.
LIPS-2-20 overhead view.
LIPS-2-20 bottom view.
LIPS-2-20 bottom view.


Яндекс цитирования