Laboratory equipment >> devices for the control armature and coating thickness

IPA-MG4.01 Thickness meter IPA-MG4.01.

IPA-MG4.01

For order is possible effectively delivery of any quantity.
Thickness meter IPA-MG4.01 (IPAMG4.01, IPA-MG-4.01, IPA MG 4.01, IPA MG4.01)
 
Thickness meter IPA-MG4.01 designed for operational control of the thickness of concrete cover and the location bar reinforcement in concrete products and structures magnetic method.
 
Technical characteristics of the instrument gauges IPA-MG4.01:
 
Diameter-controlled valves - 3mm-40mm;
Measuring range of thickness of the protective layer of concrete reinforcement bars with diameter 3mm-5mm - 3mm-90mm;
Measuring range of thickness of the protective layer of concrete reinforcement bars with diameter 6 mm to 10 mm - 3 mm to 100 mm;
Measuring range of thickness of the protective layer of concrete reinforcement bars with diameter 14mm-18mm - 5mm-120mm;
Measuring range of thickness of the protective layer of concrete reinforcement bars with diameter 20mm-40mm - 5mm-140mm;
Detection range device thickness meter IPA-MG4.01 location rebar - 3mm-140mm;
Error of measuring the thickness of concrete cover - no more than ± (0,05 hzs 0.5 nm), where hzs - the thickness of the protective layer of concrete;
The error in determining the instrument measuring the thickness of the IPA-axis MG4.01 rebar (all sizes) - ± 10 mm;
Memory - 999 measurements;
The number of groups of individual calibration curves device thickness meter IPA-MG4.01 - 9;
Power - autonomous element of type "Corundum» (6LR61) 6V-9V;
Current consumption device thickness meter IPA-MG4.01 - no more than 13mA;
Dimensions:
- Block E - 175h90h30mm;
- Converter - 160h33h40mm;
Weight of the device thickness meter IPA-MG4.01 converter - not more than 0.7 kg;
Field of application equipment - determination of the parameters and the reinforcement of concrete structures on the construction enterprises, construction sites and in the survey maintained buildings and structures;
Instruments measuring the thickness of the IPA-MG4.01 have three main modes:
- Determination of the axis of the rebar;
- Determination of the protective layer with a known diameter;
- Determination of the diameter of the rebar at a known protective layer.
Search axle rebar is to change the tone of a sound signal and a digital display on the testimony;
Instruments measuring the thickness of the IPA-MG4.01 have three groups of basic calibration curves established by the fixture class VR-I, AI and A-III;
The device further has a mode of determining the parameters of reinforcement with unknown diameter and a protective layer of concrete, equipped with the basic functions of clarification graduirovchnyh dependencies, establish and write new software device calibration curves defined by the user on the fitting of other classes;
Instrument measuring the thickness of the IPA, has MG4.01 transfer mode on the PC real-time clock and backlight;
Delivery set
- Converter;
- Electronic control unit;
- Packing case (bag);
- The belt;
- Control sample;
Vehicle Operation Manual
on request:
- Cable for connection to a computer;
- CD with software;
The manufacturer guarantees that the quality of the instrument measuring the thickness of the IPA-MG4.01 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.