Discount up to 50% on the panel devices.

Datasheets and radio parts >> connectors radio-frequency (SR-50, SR-75, E2- and others) >> coaxial transitions E2 >> coaxial transitions, couplings, adapters

E2-36

available:
11 pieces
(for order is possible effectively delivery of any quantity)
    Coaxial transition E2-36
    Also, this device can be called: E236, E2 36.

    Coaxial transition E2-36 is designed for measuring coaxial connection paths that end with the connectors connecting the series 7B-5V, the measurements of various kinds.
    Adapter coaxial measurement should conform to the general specifications in terms of requirements and standards.

    Technical specifications of the devices coaxial transitions E2-36
 
    Characteristic impedance - 50 ohms.
    Channel Types - VI - IV.
    The maximum operating frequency of transitions E2-36 - up to 3 GHz.
    Operating frequency range transitions - 2.5-10 GHz.
    The electrical length of transitions (joints) - 64 mm.

    Voltage standing wave ratio (VSWR) of the transitions:
    - At frequencies up to 3 GHz - 1.15;
    - At frequencies up to 10 GHz - 1.25.
    The efforts of the dismemberment of contact-pin socket - 0.5-2.0 kg · s.

    Test voltage transitions at the frequency of 50 Hz:
    - Under normal conditions - 1000;
    - At 98% humidity and a temperature of +40 ° C - 700 V.

    Insulation resistance E2-36
    - Normal - 1000 MW;
    - At 98% humidity and a temperature of +40 ° C - 50 MW;
    - At a temperature of +70 ° C - 50 Mohm.

    Dimensions Turnkey:
    - Screws - 22 mm and 19 mm;
    - Bushes - 17 mm.
    Weight E2-36 - not more than '60
   
   
Operating Environment E2-36
 
    Atmospheric pressure - 720-780 mm Hg
    Maximum operating voltage under normal conditions at a humidity of 98% (at a temperature of +40 ° C) - 300 V.

    Vibration resistance:
    - Frequency range - 5-200 Hz;
    - Acceleration - 7.5 m / s 2.
    Multiple-shock, acceleration - 35 m / s 2.
    Thermal stability: +70 ° C.
    Resistance to cold: -50 ° C.
    Temperature cycling, the number of cycles - 3.
    The highest relative humidity at +40 ° C - 98%.

    Shelf life transitions coaxial E2-36
    - In terms of storage - 8 years;
    - Including in the field - 3 years.

Photos: E2-36

E2-36 transition image.
E2-36 transition image.
E2-36 transition image.
E2-36 transition image.
E2-36 front view.
E2-36 front view.
E2-36 side view.
E2-36 side view.
E2-36 rear view.
E2-36 rear view.