Radiometric devices >> frequency counters, synthesizers, frequency standards >> frequency counters Ch2

Ч2-1 волномер

available: 2 pieces
device image.

Ч2-1 волномер резонансный предназначен для измерения частоты непрерывных и модулированных электромагнитных колебаний.

Диапазон частот - от 0,8 МГц до 12 МГц.

Основная погрешность измерения частоты - 0,25%.


More info ...

Ch2-11

Ch2-11 cymometer.
    Resonant Ch2-11 cymometer coaxial frequency measurement is used for continuous and pulse-modulated signals.
    The basic error of measurement - 0.05%.
    Frequency - 4000 5660MGts.

More info ...

CH2-19A

available: 9 pieces
P2-19A frequency meter resonance.
CH2-19A frequency meter resonant (CH219A, CH 2 19A, CH-2-19A, CH2 19A, CH-219A, CH 219A)
Designed to measure the frequency of continuous and pulse-modulated signals;
The basic error of measurement - 0.05%;
Frequency range - 1500MHz-2500MGts;
Sensitivity in continuous mode - 0.1 mW.

More info ...

CH2-2

available: 5 pieces
Frequency counter P2-2 resonance.
Frequency counter CH2-2 resonance (CH22, CH 2 2, CH-2-2, CH2 2, CH-22, CH 22)
Designed to measure the frequency of continuous and pulse-modulated signals;
The basic error of measurement - 0.5%;
Frequency range - 40MHz-180MHz;
Sensitivity in continuous mode - 0.8 mW.

More info ...

CH2-25

available: 8 pieces
P2-25 frequency counter resonance.
CH2-25 frequency counter resonant (CH225, CH 2 25, CH-2-25, CH2 25, CH-225, CH 225)
Designed to measure the frequency of continuous and pulse-modulated signals;
The basic error of measurement - 0.1%;
Frequency range - 36.14 GHz-52 63GGts;
Sensitivity in continuous mode - 5mW.

More info ...

CH2-26

available: 7 pieces
P2-26 frequency counter resonance.
CH2-26 frequency counter resonant (CH226, CH 2 26, CH-2-26, CH2 26, CH-226, CH 226)
Designed to measure the frequency of continuous and pulse-modulated signals;
The basic error of measurement - 0.1%;
Frequency range - 52.63 GHz-78 95GGts;
Sensitivity in continuous mode - 5mW.

More info ...

CH2-31

available: 6 pieces
P2-31 frequency counter resonance.
CH2-31 frequency counter resonant (CH231, CH 2 31, CH-2-31, CH2 31, CH-231, CH 231)
Designed to measure the frequency of continuous and pulse-modulated signals;
The basic error of measurement - 0.05%;
Frequency range - 12GGts-16 66GGts;
Sensitivity in continuous mode - 5mW.

More info ...

CH2-32

available: 5 pieces
P2-32 frequency counter resonance.
CH2-32 frequency counter resonant (CH232, CH 2 32, CH-2-32, CH2 32, CH-232, CH 232)
Designed to measure the frequency of continuous and pulse-modulated signals;
The basic error of measurement - 0.05%;
Frequency range - 8.82 GHz 12GGts;
Sensitivity in continuous mode - 5mW.

More info ...

CH2-33

available: 9 pieces
P2-33 frequency counter resonance.
CH2-33 frequency counter resonant (CH233, CH 2 33, CH-2-33, CH2 33, CH-233, CH 233)
Designed to measure the frequency of continuous and pulse-modulated signals;
The basic error of measurement - 0.05%;
Frequency range - 7GGts-9GGts;
Sensitivity in continuous mode - 5mW.

More info ...

CH2-34

available: 10 pieces
P2-34 frequency counter resonance.
CH2-34 frequency counter resonant (CH234, CH 2 34, CH-2-34, CH2 34, CH-234, CH 234)
Designed to measure the frequency of continuous and pulse-modulated signals;
The basic error of measurement - 0.05%;
Frequency range - 3300MGts-4300MGts;
Sensitivity in continuous mode - 0.2 mW.

More info ...