Electrical measuring instruments >> transformers industrial >> current transformers >> 20kV voltage class

TOL-20-2

29 500 RUB   |   35 400 UAH
TOL-20-2 transformer image.
Current transformer TOL-20-2 (TOL202, TOL 20 2, TOL-202, TOL 202, TOL20-2, TOL20 2, TOL-20-II)
Designed for installation in the Switchgear (switchgear, metal-clad switchgear, CSR), and serves to signal measurement information instrumentation and (or) protection and control, to isolate the chains of secondary compounds of high-voltage electrical installations AC voltage class up to 20kV 50Hz or 60Hz;
The number of secondary windings - 2;
Rated voltage - 20kV;
Maximum operating voltage - 24kV;
Rated secondary - 1A, 5A;
Rated primary current - 5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A, 1000A, 1200A, 1500A, 2000A, 2500A, 3000A;
Accuracy class - 0,2 S, 0,2, 0,5 S, 0,5, 1, 3, 5P, 10P.

More info ...

TOL-20-3

33 925 RUB   |   40 710 UAH
TOL-20-3 transformer image.
Current transformer TOL-20-3 (TOL203, TOL 20 3, TOL-203, TOL 203, TOL20-3, TOL20 3, TOL-20-III)
Designed for installation in the Switchgear (switchgear, metal-clad switchgear, CSR), and serves to signal measurement information instrumentation and (or) protection and control, to isolate the chains of secondary compounds of high-voltage electrical installations AC voltage class up to 20kV 50Hz or 60Hz;
The number of secondary windings - 3;
Rated voltage - 20kV;
Maximum operating voltage - 24kV;
Rated secondary - 1A, 5A;
Rated primary current - 5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A, 1000A, 1200A, 1500A, 2000A, 2500A, 3000A;
Accuracy class - 0,2 S, 0,2, 0,5 S, 0,5, 1, 3, 5P, 10P.

More info ...

TOL-20-4

38 350 RUB   |   46 020 UAH
TOL-20-4 transformer image.
Current transformer TOL-20-4 (TOL204, TOL 20 4, TOL-204, TOL 204, TOL20-4, TOL20 4, TOL-20-IV)
Designed for installation in the Switchgear (switchgear, metal-clad switchgear, CSR), and serves to signal measurement information instrumentation and (or) protection and control, to isolate the chains of secondary compounds of high-voltage electrical installations AC voltage class up to 20kV 50Hz or 60Hz;
The number of secondary windings - 4;
Rated voltage - 20kV;
Maximum operating voltage - 24kV;
Rated secondary - 1A, 5A;
Rated primary current - 5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A, 1000A, 1200A, 1500A, 2000A, 2500A, 3000A;
Accuracy class - 0,2 S, 0,2, 0,5 S, 0,5, 1, 3, 5P, 10P.

More info ...

TPL-20

41 285 RUB   |   49 542 UAH
TPL-20 transformer image.
Current transformer TPL-20 (TPL20, TPL 20)
Designed for measuring data transmission measurement devices, protection, automation, alarm and control circuits to isolate the secondary connections of high voltage electrical installations in the AC;
The number of secondary windings - 2;
Rated voltage - 20kV;
Maximum operating voltage - 24kV;
Rated secondary - 1A, 5A;
Rated primary current - 300A, 400A, 600A, 800A, 1000A, 1500A, 2000A, 3000A, 4000A;
Accuracy class - 0,2 S, 0,2, 0,5 S, 0,5, 1, 5P, 10P.

More info ...

TSHL-20-1

103 825 RUB   |   124 590 UAH
TSHL-20-1 transformer image.
Current transformer TOL-20-4 (TOL204, TOL 20 4, TOL-204, TOL 204,  TOL20-4, TOL20 4, TOL-20-IV)
Designed for installation in the Switchgear (switchgear, metal-clad switchgear, CSR), and serves to signal measurement information instrumentation and (or) protection and control, to isolate the chains of secondary compounds of high-voltage electrical installations AC voltage class up to 20kV 50Hz or 60Hz;
The number of secondary windings - 4;
Rated voltage - 20kV;
Maximum operating voltage - 24kV;
Rated secondary - 1A, 5A;
Rated primary current - 5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A, 1000A, 1200A, 1500A, 2000A, 2500A, 3000A;
Accuracy class - 0,2 S, 0,2, 0,5 S, 0,5, 1, 3, 5P, 10P.

More info ...

TLSH-20-1-3

112 675 RUB   |   135 210 UAH
TLSH-20-1-3 transformer image.
Current transformer TSHL-20-1-3 (TSHL2013, TSHL 20 1 3, TSHL 2013, TSHL 2013, TSHL20-1-3, TSHL20 1 3, TSHL-20-I-III)
Designed for measuring data transmission measurement devices, protection, automation, alarm and control circuits to isolate the secondary connections of high voltage electrical installations in the AC;
The number of secondary windings - 3;
Rated voltage - 20kV;
Maximum operating voltage - 24kV;
Rated secondary - 5A;
Rated primary current - 3000A, 4000A, 5000A, 6000A, 8000A, 10000A, 12000A, 14000A, 16000A, 18000A;
Accuracy class - 0,2 S, 0,2, 0,5 S, 0,5, 5P, 10P.

More info ...
TLSH-20-1-3TOL-20-2TOL-20-3
TOL-20-4TPL-20TSHL-20-1


Яндекс цитирования