DC Power Supply B5-45 (B5 45, B545)
Designed to power the radio equipment of DC voltage.
The limit of output voltage of 0.1 V - 49.9 in
Limit of setting the output current 0.001 A - 0.499 A

 
DC Power Supply B5-45 power supply designed for wireless devices constant voltage. DC Power Supply B5-45 may work in the laboratory.
Operating conditions:
ambient temperature from 278 to 313 K (5 to 40 ° C);
Relative humidity up to (90-95)% at a temperature of 303 K (30 ° C), atmospheric pressure 100 ± 4 kPa (750 ± 30 mm Hg. centuries). voltage 220 ± 22 V.
Technical data
DC Power B5-45 operate in voltage mode and current stabilization. The limits set output voltages and currents are shown in Table 1.
 
Table 1.
Device Type The limit of output voltage, V Limit of setting the output current, A
B5-45 0.1 - 49.9 0,001 - 0,499

The output voltage is regulated devices in 100 mV steps.
The output current of the device is regulated through the steps of 1 mA.
The basic error of the output voltage in voltage does not exceed the following values:
± (0,5% U mouth + 0,1% U max) V.
The basic error of the output current in voltage does not exceed the following values: ± (1,0% J mouth + 0,2% J max) A.
The instability of the output voltage when the supply voltage by ± 10% from the nominal value in voltage does not exceed the following values:
± 0,01% - over a 1-20; ± 0,01% - 5 min.
The instability of the output current when the supply voltage of ± 10% of nominal mode constant current does not exceed the following values:
± 0,05% - for 1-20 seconds; 0.05% - 5 min.
Instability of output voltage when the load current of 0.9 the maximum value to zero in voltage does not exceed the following values:
± 0,05% - over a 1-20; ± 0,05% - 5 min.
Instability of the output current when the load voltage of 0.9 the maximum value to zero in the constant current mode does not exceed the following values:
± 0,1% J max - for 1-20 seconds;
± 0,1% J max - For 5 minutes.
Output voltage ripple devices in voltage is less than 1 mV rms value.
Ripple current output device B5-45 current stabilization mode does not exceed 0,2% J max effective value.
Additional error of the output voltage when the temperature at 283 K (10 ° C) in voltage does not exceed half of the basic error mentioned above.
Additional error output current with variation in temperature of 283 K (10 ° C) in a constant current mode, does not exceed 1/2 of the basic error mentioned above.
Output voltage drift over 8 hours of continuous operation and for any 10 minutes, eliminating the time samoprogreva not exceed the value of the basic error mentioned above.
Offset drift over 8 hours of continuous operation and for any 10 minutes, eliminating the time samoprogreva, does not exceed the basic error of the above.
DC Power Supply B5-45 has a manual (front panel) and remote control of the output voltage and output current, and the device B5-45/1 - only manual control.
Remote control is a contact closure 2-13 and 18-29 remote control connectors to contact 50 TOTAL same connector. Pin Numbers for the remote control and the corresponding values of output voltages and currents, resulting from the closure of them, are shown in Table. 2.3.
 
Table 2
The value to set the output voltage, V

Pin Numbers

REMOTE CONTROL
B5-45 2 3 4 5 6 7 8 9 10 11 12 13
0.1 1 0 0 0 0 0 0 0 0 0 0 0
0.2 0 1 0 0 0 0 0 0 0 0 0 0
0.4 0 0 1 0 0 0 0 0 0 0 0 0
0.8 0 0 0 1 0 0 0 0 0 0 0 0
1.0 0 0 0 0 1 0 0 0 0 0 0 0
2.0 0 0 0 0 0 1 0 0 0 0 0 0
4.0 0 0 0 0 0 0 1 0 0 0 0 0
8.0 0 0 0 0 0 0 0 1 0 0 0 0
10.0 0 0 0 0 0 0 0 0 1 0 0 0
20.0 0 0 0 0 0 0 0 0 0 1 0 0
40.0 0 0 0 0 0 0 0 0 0 0 1 0
- 0 0 0 0 0 0 0 0 0 0 0 1
 
Table 3
The value to set the output current, A

Pin Numbers

REMOTE CONTROL
B5-45 18 19 20 21 22 23 24 25 26 27 28 29
0,001 1 0 0 0 0 0 0 0 0 0 0 0
0,002 0 1 0 0 0 0 0 0 0 0 0 0
0,004 0 0 1 0 0 0 0 0 0 0 0 0
0,008 0 0 0 1 0 0 0 0 0 0 0 0
0.01 0 0 0 0 1 0 0 0 0 0 0 0
0.02 0 0 0 0 0 1 0 0 0 0 0 0
0.04 0 0 0 0 0 0 1 0 0 0 0 0
0.08 0 0 0 0 0 0 0 1 0 0 0 0
0.1 0 0 0 0 0 0 0 0 1 0 0 0
0.2 0 0 0 0 0 0 0 0 0 1 0 0
0.4 0 0 0 0 0 0 0 0 0 0 1 0
- 0 0 0 0 0 0 0 0 0 0 0 1
 
Note. 1 - denotes the closure of the specified contact to contact 50 COMMON connector REMOTE CONTROL.
In devices provides protection against overloads and short circuits at the output of the unit B5-45 by the automatic switch from the voltage regulation at constant current mode and vice versa.
The maximum time setting of the output voltage from zero to a maximum value of 0.9 from the date of the management team does not exceed 100 ms.
The output impedance in voltage in the frequency range from 20 Hz to 200 kHz prevyshaet4 ohms.
Allowable modulation index is less than 5% in the frequency range from 20 Hz to 20 kHz in voltage.
Maximum emission output voltage when the load changes from 0.9 maximum value to zero in the constant current mode is not more than 5 V.
Emissions less than 5. The time setting of the output voltage when the load current of 0.9 the maximum value to 0 in voltage does not exceed 100 ms.
DC Power Supply B5-45 allows serial connection of two devices of the same type in voltage. The instruments provide production and operating margin of at least 20% in the following output parameters:
error of the output voltage error of the output current;
instability of the output voltage when the supply voltage of ± 10% of rated voltage regulation;
volatility of output current when the supply voltage of ± 10% of nominal current regulation mode;
instability of the output voltage when the load current of 0.9 the maximum value to zero in voltage;
instability of the output current when the load voltage of 0.9 the maximum value to zero in the constant current mode;
output voltage ripple in voltage;
Ripple current in the output current stabilization mode.
Electrical isolation output circuits can withstand without breakdown test voltage of 500 V.
The insulation resistance of these circuits unit B5-45 relative to the body of at least 200, 5, 1 M, respectively, for normal conditions, higher operating temperatures and humidity.
Electrical isolation between any of the pins the network cable and the housing unit is built to withstand the test of breakdown voltage 1500 V AC. The values ​​of the stress test after test The humidity should be installed by a factor of 0.6.
Any device output terminal is grounded. DC Power Supply B5-45 provides its specifications within the rules after 30 minutes of switching on.
The device is powered from an AC voltage of 220 ± 22 V, ± 0,5 at 50 Hz and harmonic content up to 5%. Power consumed by the device does not exceed 150 VA. DC Power Supply B5-45 permits continuous operation of the operating conditions for 8 hours MTBF - 4800 h Service life - 6 years, technical resource - 5000 h Overall device dimensions 326 x 236 x 93 mm. Dimensions of transport container 564 x 346 x 262 mm.
Unit weight kg -7.
Weight of the device B5-45 in shipping container - 12 kg.

Photos B5-45

B5-45 device image.
B5-45 device image.
B5-45 front view.
B5-45 front view.
B5-45 side view.
B5-45 side view.
B5-45 rear view.
B5-45 rear view.