Products catalog
Price:
on request
Product information updated 07 December 2024.
Found cheaper?
Let us know. Our price is the best.
Warranty:
12 months.
Warranty extension up to 5 years.
Terms of delivery:
To all regions of the country, international delivery.
Product information updated 07 December 2024.
Found cheaper?
Let us know. Our price is the best.
Warranty:
12 months.
Warranty extension up to 5 years.
Terms of delivery:
To all regions of the country, international delivery.
Technical characteristics
Voltmeter V7-46/1 universal (V746/1, V-7-46/1, V 7 46/1, b7-46/1, V-746/1, V 746/1, b746/1, b-7-46/1, b 7 46/1, b-746/1, b 746/1)
Ranges
|
Bystrodey-consequence
|
The quantization step (number of indications)
|
20mV
|
0.1 measurements / a
|
100nV (5 1/2)
|
1izmer / s
|
1mkV (4 1/2)
|
|
5izmer / s
|
10mkV (3 1/2)
|
|
200mV
|
5izmer / s
|
1mkV (5 1/2)
|
10izmer / s
|
10mkV (4 1/2)
|
|
50izmer / s
|
100mkV (3 1/2)
|
|
2B
|
5izmer / s
|
10mkV (5 1/2)
|
10izmer / s
|
100mkV (4 1/2)
|
|
50izmer / s
|
1mV (3 1/2)
|
|
20B
|
5izmer / s
|
100mkV (5 1/2)
|
10izmer / s
|
1mV (4 1/2)
|
|
50izmer / s
|
10mV (3 1/2)
|
|
200V
|
5izmer / s
|
1mV (5 1/2)
|
10izmer / s
|
10mV (4 1/2)
|
|
50izmer / s
|
100mV (3 1/2)
|
|
1000V
|
5izmer / s
|
10mV (5 1/2)
|
10izmer / s
|
100mV (4 1/2)
|
|
50izmer / s
|
1B (3 1/2)
|
Ranges
|
Maximum permissible error for calibration interval
|
|
24h
|
6 months
|
|
20mV
|
± [0,03 +0,02 (U a / U-1)]%
|
± [0,04 +0,02 (U a / U-1)]%
|
± [0,03 +0,025 (U a / U-1)]%
|
± [0,04 +0,025 (U a / U-1)]%
|
|
± [0,1 +0,1 (U a / U-1)]%
|
± [0,15 +0,1 (U a / U-1)]%
|
|
200mV
|
± [0,015 +0,0025 (U a / U-1)]%
|
± [0,025 +0,0025 (U a / U-1)]%
|
± [0,02 +0,015 (U a / U-1)]%
|
± [0,025 +0,02 (U a / U-1)]%
|
|
± [0,1 +0,1 (U a / U-1)]%
|
± [0,15 +0,1 (U a / U-1)]%
|
|
2B
|
± [0,01 +0,002 (U a / U-1)]%
|
± [0,02 +0,002 (U a / U-1)]%
|
± [0,015 +0,01 (U a / U-1)]%
|
± [0,02 +0,015 (U a / U-1)]%
|
|
± [0,1 +0,1 (U a / U-1)]%
|
± [0,15 +0,1 (U a / U-1)]%
|
|
20B
|
± [0,015 +0,002 (U a / U-1)]%
|
± [0,02 +0,002 (U a / U-1)]%
|
± [0,02 +0,01 (U a / U-1)]%
|
± [0,025 +0,01 (U a / U-1)]%
|
|
± [0,1 +0,1 (U a / U-1)]%
|
± [0,15 +0,1 (U a / U-1)]%
|
|
200V
|
± [0,015 +0,002 (U a / U-1)]%
|
± [0,02 +0,002 (U a / U-1)]%
|
± [0,02 +0,01 (U a / U-1)]%
|
± [0,025 +0,02 (U a / U-1)]%
|
|
± [0,1 +0,1 (U a / U-1)]%
|
± [0,15 +0,1 (U a / U-1)]%
|
|
1000V
|
± [0,02 +0,004 (U a / U-1)]%
|
± [0,025 +0,004 (U a / U-1)]%
|
± [0,03 +0,02 (U a / U-1)]%
|
± [0,04 +0,02 (U a / U-1)]%
|
|
± [0,2 +0,1 (U a / U-1)]%
|
± [0,25 +0,1 (U a / U-1)]%
|
Table 1.2 Maximum permissible error of measurement of dc voltage
Ranges
|
Bystrodey-consequence
|
The quantization step (number of indications)
|
20mV
|
0.1 measurements / a
|
100nV (5 1/2)
|
1izmer / s
|
1mkV (4 1/2)
|
|
5izmer / s
|
10mkV (3 1/2)
|
|
200mV
|
5izmer / s
|
1mkV (5 1/2)
|
10izmer / s
|
10mkV (4 1/2)
|
|
50izmer / s
|
100mkV (3 1/2)
|
|
2B
|
5izmer / s
|
10mkV (5 1/2)
|
10izmer / s
|
100mkV (4 1/2)
|
|
50izmer / s
|
1mV (3 1/2)
|
|
20B
|
5izmer / s
|
100mkV (5 1/2)
|
10izmer / s
|
1mV (4 1/2)
|
|
50izmer / s
|
10mV (3 1/2)
|
|
200V
|
5izmer / s
|
1mV (5 1/2)
|
10izmer / s
|
10mV (4 1/2)
|
|
50izmer / s
|
100mV (3 1/2)
|
|
1000V
|
5izmer / s
|
10mV (5 1/2)
|
10izmer / s
|
100mV (4 1/2)
|
|
50izmer / s
|
1B (3 1/2)
|
Ranges
|
Maximum permissible error for calibration interval
|
|
12 months
|
24 months
|
|
20mV
|
± [0,05 +0,02 (U a / U-1)]%
|
± [0,06 +0,03 (U a / U-1)]%
|
± [0,05 +0,025 (U a / U-1)]%
|
± [0,08 +0,03 (U a / U-1)]%
|
|
± [0,2 +0,1 (U a / U-1)]%
|
± [0,3 +0,1 (U a / U-1)]%
|
|
200mV
|
± [0,025 +0,0025 (U a / U-1)]%
|
± [0,04 +0,003 (U a / U-1)]%
|
± [0,03 +0,025 (U a / U-1)]%
|
± [0,05 +0,03 (U a / U-1)]%
|
|
± [0,1 +0,1 (U a / U-1)]%
|
± [0,25 +0,1 (U a / U-1)]%
|
|
2B
|
± [0,025 +0,0025 (U a / U-1)]%
|
± [0,03 +0,003 (U a / U-1)]%
|
± [0,025 +0,02 (U a / U-1)]%
|
± [0,04 +0,02 (U a / U-1)]%
|
|
± [0,15 +0,1 (U a / U-1)]%
|
± [0,25 +0,1 (U a / U-1)]%
|
|
20B
|
± [0,025 +0,0025 (U a / U-1)]%
|
± [0,04 +0,003 (U a / U-1)]%
|
± [0,025 +0,02 (U a / U-1)]%
|
± [0,04 +0,02 (U a / U-1)]%
|
|
± [0,15 +0,1 (U a / U-1)]%
|
± [0,25 +0,1 (U a / U-1)]%
|
|
200V
|
± [0,03 +0,002 (U a / U-1)]%
|
± [0,05 +0,003 (U a / U-1)]%
|
± [0,03 +0,02 (U a / U-1)]%
|
± [0,05 +0,03 (U a / U-1)]%
|
|
± [0,15 +0,1 (U a / U-1)]%
|
± [0,25 +0,1 (U a / U-1)]%
|
|
1000V
|
± [0,03 +0,004 (U a / U-1)]%
|
± [0,04 +0,006 (U a / U-1)]%
|
± [0,05 +0,02 (U a / U-1)]%
|
± [0,08 +0,03 (U a / U-1)]%
|
|
± [0,25 +0,1 (U a / U-1)]%
|
± [0,4 +0,2 (U a / U-1)]%
|
Table. 1.1, 1.2, and on the following notation:
Calibration interval
|
Frequency band
|
Maximum permissible error of measurement time 0.33 s, 2 s, by measuring ranges with limits
|
200mV
|
||
6 months
|
20Hz-60Hz
|
± [0,4 +0,1 (U a / U-1)]%
|
60Hz-400Hz
|
± [0,4 +0,1 (U a / U-1)]%
|
|
400Hz-10kHz
|
± [0,3 +0,15 (U a / U-1)]%
|
|
10kHz-20kHz
|
± [0,4 +0,15 (U a / U-1)]%
|
|
20kHz-100kHz
|
± [0,6 +0,15 (U a / U-1)]%
|
|
100kHz, 300kHz
|
± [5 +1 (U a / U-1)]%
|
|
300kHz-1000kGts
|
-
|
|
12 months
|
20Hz-40Hz
|
± [0,5 +0,1 (U a / U-1)]%
|
400Hz-20kHz
|
± [0,5 +0,15 (U a / U-1)]%
|
|
20kHz-100kHz
|
± [2 +0,15 (U a / U-1)]%
|
|
100kHz, 300kHz
|
± [10 +2 (U a / U-1)]%
|
|
300kHz-1000kGts
|
-
|
|
24 months
|
20Hz-400Hz
|
± [0,6 +0,2 (U a / U-1)]%
|
400Hz-20kHz
|
± [0,6 +0,25 (U a / U-1)]%
|
|
20kHz-100kHz
|
± [2 +0,25 (U a / U-1)]%
|
|
100kHz, 300kHz
|
± [12 +2 (U a / U-1)]%
|
|
300kHz-1000kGts
|
-
|
Mezhpoveterm interval
|
Frequency band
|
Maximum permissible error of measurement time 0.33 s, 2 s, by measuring ranges with limits
|
Limit
permissible basic error of measurement time 0.33 s, 2 s, for measuring ranges with limits |
|
2B
|
20B
|
|||
6 months
|
20Hz-60Hz
|
± [0,4 +0,1 (U a / U-1)]%
|
± [0,4 +0,1 (U a / U-1)]%
|
|
60Hz-400Hz
|
± [0,3 +0,1 (U a / U-1)]%
|
± [0,3 +0,1 (U a / U-1)]%
|
||
400Hz-10kHz
|
± [0,15 +0,1 (U a / U-1)]%
|
± [0,15 +0,1 (U a / U-1)]%
|
||
10kHz-20kHz
|
± [0,3 +0,1 (U a / U-1)]%
|
± [0,3 +0,1 (U a / U-1)]%
|
||
20kHz-100kHz
|
± [0,6 +0,1 (U a / U-1)]%
|
± [0,6 +0,1 (U a / U-1)]%
|
||
100kHz, 300kHz
|
± [2,5 +0,4 (U a / U-1)]%
|
± [2,5 +0,4 (U a / U-1)]%
|
||
300kHz-1000kGts
|
± [5 +1 (U a / U-1)]%
|
± [5 +1 (U a / U-1)]%
|
||
12 months
|
20Hz-40Hz
|
± [0,5 +0,1 (U a / U-1)]%
|
± [0,5 +0,1 (U a / U-1)]%
|
|
400Hz-20kHz
|
± [0,4 +0,15 (U a / U-1)]%
|
± [0,4 +0,15 (U a / U-1)]%
|
||
20kHz-100kHz
|
± [1,5 +0,15 (U a / U-1)]%
|
± [1,5 +0,15 (U a / U-1)]%
|
||
100kHz, 300kHz
|
± [5 +1 (U a / U-1)]%
|
± [5 +1 (U a / U-1)]%
|
||
300kHz-1000kGts
|
± [10 +2 (U a / U-1)]%
|
± [10 +2 (U a / U-1)]%
|
||
24 months
|
20Hz-400Hz
|
± [0,6 +0,2 (U a / U-1)]%
|
± [0,6 +0,2 (U a / U-1)]%
|
|
400Hz-20kHz
|
± [0,6 +0,2 (U a / U-1)]%
|
± [0,6 +0,2 (U a / U-1)]%
|
||
20kHz-100kHz
|
± [2 +0,25 (U a / U-1)]%
|
± [2,5 +0,25 (U a / U-1)]%
|
||
100kHz, 300kHz
|
± [6 +1 (U a / U-1)]%
|
± [6 +1 (U a / U-1)]%
|
||
300kHz-1000kGts
|
± [12 +1,5 (U a / U-1)]%
|
± [12 +1,5 (U a / U-1)]%
|
Table 1.4 Maximum permissible error of measurement of AC-form
Mezhpoveterm interval
|
Frequency band
|
Maximum permissible error of measurement time 0.33 s, 2 s, by measuring ranges with limits
|
|
200V
|
700V
|
||
6 months
|
20Hz-400Hz
|
± [0,4 +0,1 (U a / U-1)]%
|
± [0,5 +0,1 (U a / U-1)]%
|
400Hz-10kHz
|
± [0,25 +0,6 (U a / U-1)]%
|
± [0,4 +0,06 (U a / U-1)]%
|
|
10kHz-20kHz
|
± [0,4 +0,1 (U a / U-1)]%
|
± [0,6 +0,1 (U a / U-1)]%
|
|
20kHz-100kHz
|
± [0,6 +0,1 (U a / U-1)]%
|
± [0,6 +0,1 (U a / U-1)]%
|
|
12 months
|
20Hz-400Hz
|
± [0,5 +0,1 (U a / U-1)]%
|
± [0,8 +0,1 (U a / U-1)]%
|
400Hz-10kHz
|
± [0,5 +0,15 (U a / U-1)]%
|
± [0,5 +0,15 (U a / U-1)]%
|
|
10kHz-20kHz
|
± [0,5 +0,15 (U a / U-1)]%
|
± [0,8 +0,15 (U a / U-1)]%
|
|
20kHz-100kHz
|
± [1,5 +0,15 (U a / U-1)]%
|
± [2 +0,15 (U a / U-1)]%
|
|
24 months
|
20Hz-400Hz
|
± [0,6 +0,2 (U a / U-1)]%
|
± [1 +0,3 (U a / U-1)]%
|
400Hz-10kHz
|
± [0,6 +0,2 (U a / U-1)]%
|
± [1 +0,3 (U a / U-1)]%
|
|
10kHz-20kHz
|
± [0,6 +0,3 (U a / U-1)]%
|
± [1 +0,3 (U a / U-1)]%
|
|
20kHz-100kHz
|
± [2,5 +0,25 (U a / U-1)]%
|
± [3 +0,4 (U a / U-1)]%
|
Table 1.5 Maximum permissible error of measurement of AC-form
Calibration interval
|
Frequency band
|
Maximum permissible error of measurement time 0.33 s, 2 s, by measuring ranges with limits
|
200mV
|
||
6 months
|
400Hz-10kHz
|
± [0,5 +0,2 (U a / U-1)]%
|
10kHz-20kHz
|
± [0,6 +0,2 (U a / U-1)]%
|
|
20kHz-100kHz
|
± [1 +0,3 (U a / U-1)]%
|
|
0.1 MHz-0, 3MHz
|
± [6 +2 (U a / U-1)]%
|
|
0.3 MHz to 1 MHz
|
-
|
|
12 months
|
400Hz-20kHz
|
± [0,6 +0,3 (U a / U-1)]%
|
20kHz-100kHz
|
± [2 +0,3 (U a / U-1)]%
|
|
0.1 MHz-0, 3MHz
|
± [10 +2 (U a / U-1)]%
|
|
0.3 MHz to 1 MHz
|
-
|
|
24 months
|
400Hz-20kHz
|
± [1 +0,5 (U a / U-1)]%
|
20kHz-100kHz
|
± [3 +0,4 (U a / U-1)]%
|
|
0.1 MHz-0, 3MHz
|
± [15 +2 (U a / U-1)]%
|
|
0.3 MHz to 1 MHz
|
-
|
Mezhpoveterm interval
|
Frequency band
|
Maximum permissible error of measurement time 0.33 s, 2 s, by measuring ranges with limits
|
Maximum permissible error of measurement time 0.33 s, 2 s, by measuring ranges with limits
|
|
2B
|
20B
|
|||
6 months
|
400Hz-10kHz
|
± [0,3 +0,1 (U a / U-1)]%
|
± [0,3 +0,15 (U a / U-1)]%
|
|
10kHz-20kHz
|
± [0,5 +0,25 (U a / U-1)]%
|
± [0,5 +0,25 (U a / U-1)]%
|
||
20kHz-100kHz
|
± [1 +0,25 (U a / U-1)]%
|
± [1 +0,25 (U a / U-1)]%
|
||
0.1 MHz-0, 3MHz
|
± [4 +0,4 (U a / U-1)]%
|
± [4 +0,5 (U a / U-1)]%
|
||
0.3 MHz to 1 MHz
|
± [6 +2 (U a / U-1)]%
|
± [6 +3 (U a / U-1)]%
|
||
12 months
|
400Hz-20kHz
|
± [0,6 +0,25 (U a / U-1)]%
|
± [0,6 +0,25 (U a / U-1)]%
|
|
20kHz-100kHz
|
± [2,5 +0,25 (U a / U-1)]%
|
± [2,5 +0,25 (U a / U-1)]%
|
||
0.1 MHz-0, 3MHz
|
± [6 +1,5 (U a / U-1)]%
|
± [6 +1,5 (U a / U-1)]%
|
||
0.3 MHz to 1 MHz
|
± [12 +2 (U a / U-1)]%
|
± [12 +2 (U a / U-1)]%
|
||
24 months
|
400Hz-20kHz
|
± [1 +0,5 (U a / U-1)]%
|
± [1 +0,5 (U a / U-1)]%
|
|
20kHz-100kHz
|
± [4 +0,4 (U a / U-1)]%
|
± [4 +0,4 (U a / U-1)]%
|
||
0.1 MHz-0, 3MHz
|
± [8 +1,5 (U a / U-1)]%
|
± [8 +1,5 (U a / U-1)]%
|
||
0.3 MHz to 1 MHz
|
± [15 +2 (U a / U-1)]%
|
± [15 +2 (U a / U-1)]%
|
Table 1.6 Maximum permissible error of measurement of AC-form
Mezhpoveterm interval
|
Frequency band
|
Maximum permissible error of measurement time 0.33 s, 2 s, by measuring ranges with limits
|
|
200V
|
700V
|
||
6 months
|
400Hz-10kHz
|
± [0,4 +0,2 (U a / U-1)]%
|
± [0,5 +0,2 (U a / U-1)]%
|
10kHz-20kHz
|
± [0,6 +0,3 (U a / U-1)]%
|
± [0,5 +0,3 (U a / U-1)]%
|
|
20kHz-100kHz
|
± [1 +0,25 (U a / U-1)]%
|
± [1 +0,4 (U a / U-1)]%
|
|
12 months
|
400Hz-20kHz
|
± [0,6 +0,3 (U a / U-1)]%
|
± [1 +0,4 (U a / U-1)]%
|
20kHz-100kHz
|
± [2,5 +0,25 (U a / U-1)]%
|
± [2,5 +0,4 (U a / U-1)]%
|
|
24 months
|
400Hz-20kHz
|
± [1 +0,5 (U a / U-1)]%
|
± [1,5 +1 (U a / U-1)]%
|
20kHz-100kHz
|
± [4 +0,4 (U a / U-1)]%
|
± [4 +0,5 (U a / U-1)]%
|
Input impedance voltmeter V7-46/1 in the measurement of AC voltage is 2 megohms ± 0,1 MW, the input capacitance of less than 50pF;
Ranges
|
Bystrodey-consequence
|
The quantization step (number of indications)
|
20mkA
|
5izmer / s
|
100pA (5 1/2)
|
10izmer / s
|
1nA (4 1/2)
|
|
50izmer / s
|
10on (3 1/2)
|
|
200uA
|
5izmer / s
|
1nA (5 1/2)
|
10izmer / s
|
10on (4 1/2)
|
|
50izmer / s
|
100nA (3 1/2)
|
|
2mA
|
5izmer / s
|
10on (5 1/2)
|
10izmer / s
|
100nA (4 1/2)
|
|
50izmer / s
|
1 uA (3 1/2)
|
|
20mA
|
5izmer / s
|
100nA (5 1/2)
|
10izmer / s
|
1 uA (4 1/2)
|
|
50izmer / s
|
10uA (3 1/2)
|
|
200mA
|
5izmer / s
|
1 uA (5 1/2)
|
10izmer / s
|
10uA (4 1/2)
|
|
50izmer / s
|
100uA (3 1/2)
|
|
2000mA
|
5izmer / s
|
10uA (5 1/2)
|
10izmer / s
|
100uA (4 1/2)
|
|
50izmer / s
|
1mA (3 1/2)
|
Ranges
|
Maximum permissible error for calibration interval
|
|
24h
|
6 months
|
|
20mkA
|
± [0,15 +0,1 (I a / I-1)]%
|
± [0,25 +0,025 (I a / I-1)]%
|
± [0,15 +0,02 (I a / I-1)]%
|
± [0,25 +0,025 (I a / I-1)]%
|
|
± [0,15 +0,1 (I a / I-1)]%
|
± [0,25 +0,1 (I a / I-1)]%
|
|
200uA
|
± [0,1 +0,005 (I a / I-1)]%
|
± [0,15 +0,01 (I a / I-1)]%
|
± [0,1 +0,001 (I a / I-1)]%
|
± [0,15 +0,015 (I a / I-1)]%
|
|
± [0,15 +0,1 (I a / I-1)]%
|
± [0,25 +0,1 (I a / I-1)]%
|
|
2mA
|
± [0,1 +0,005 (I a / I-1)]%
|
± [0,15 +0,01 (I a / I-1)]%
|
± [0,1 +0,01 (I a / I-1)]%
|
± [0,15 +0,015 (I a / I-1)]%
|
|
± [0,15 +0,1 (I a / I-1)]%
|
± [0,25 +0,1 (I a / I-1)]%
|
|
20mA
|
± [0,1 +0,005 (I a / I-1)]%
|
± [0,15 +0,01 (I a / I-1)]%
|
± [0,1 +0,01 (I a / I-1)]%
|
± [0,15 +0,015 (I a / I-1)]%
|
|
± [0,15 +0,1 (I a / I-1)]%
|
± [0,25 +0,1 (I a / I-1)]%
|
|
200mA
|
± [0,1 +0,005 (I a / I-1)]%
|
± [0,15 +0,01 (I a / I-1)]%
|
± [0,1 +0,01 (I a / I-1)]%
|
± [0,15 +0,015 (I a / I-1)]%
|
|
± [0,15 +0,1 (I a / I-1)]%
|
± [0,25 +0,15 (I a / I-1)]%
|
|
2000mA
|
± [0,1 +0,005 (I a / I-1)]%
|
± [0,15 +0,01 (I a / I-1)]%
|
± [0,1 +0,01 (I a / I-1)]%
|
± [0,15 +0,015 (I a / I-1)]%
|
|
± [0,15 +0,1 (I a / I-1)]%
|
± [0,25 +0,15 (I a / I-1)]%
|
Maximum permissible error of measuring the strength of the DC voltmeter with an external shunt up to 10A for calibration intervals of 12, 24 months, the speed, the quantization step for each range of measurement equal to the values given in tabl.1.8.
Ranges
|
Bystrodey-consequence
|
The quantization step (number of indications)
|
10A
|
5izmer / s
|
100uA (5 1/2)
|
10izmer / s
|
1mA (4 1/2)
|
|
50izmer / s
|
10mA (3 1/2)
|
Ranges
|
Maximum permissible error for calibration interval
|
|
24h
|
6 months
|
|
10A
|
± [0,4 +0,01 (I a / I-1)]%
|
± [0,6 +0,02 (I a / I-1)]%
|
± [0,4 +0,01 (I a / I-1)]%
|
± [0,6 +0,02 (I a / I-1)]%
|
|
± [0,4 +0,01 (I a / I-1)]%
|
± [0,6 +0,02 (I a / I-1)]%
|
Table. 1.7, 1.8, and on the following notation:
Mezhpoveterm interval
|
Ranges
|
Maximum permissible error of measurement time 0.33 s, 2 s, in the frequency range
|
|
40Hz-10kHz
|
10kHz-20kHz
|
||
12 months
|
200uA
|
± [0,6 +0,15 (I a / I-1)]%
|
± [0,2 +0,15 (I a / I-1)]%
|
2mA
|
± [0,6 +0,15 (I a / I-1)]%
|
± [0,2 +0,15 (I a / I-1)]%
|
|
20mA
|
± [0,6 +0,15 (I a / I-1)]%
|
± [0,2 +0,15 (I a / I-1)]%
|
|
200mA
|
± [0,6 +0,15 (I a / I-1)]%
|
± [0,2 +0,15 (I a / I-1)]%
|
|
2000mA
|
± [0,6 +0,15 (I a / I-1)]%
|
± [0,2 +0,15 (I a / I-1)]%
|
|
10A (with external shunt)
|
± [1 +0,1 (I a / I-1)]% in the frequency range 40Hz-2kHz
|
||
24 months
|
200uA
|
± [1 +0,25 (I a / I-1)]%
|
± [3 +0,3 (I a / I-1)]%
|
2mA
|
± [1 +0,25 (I a / I-1)]%
|
± [3 +0,3 (I a / I-1)]%
|
|
20mA
|
± [1 +0,25 (I a / I-1)]%
|
± [3 +0,3 (I a / I-1)]%
|
|
200mA
|
± [1 +0,25 (I a / I-1)]%
|
± [3 +0,3 (I a / I-1)]%
|
|
2000mA
|
± [1 +0,25 (I a / I-1)]%
|
± [3 +0,3 (I a / I-1)]%
|
|
10A (with external shunt)
|
± [1,5 +0,15 (I a / I-1)]% in the frequency range 40Hz-2kHz
|
Table 1.10 Maximum permissible error of measurement of AC current freeform
Calibration interval
|
Ranges
|
Maximum permissible error of measurement time 0.33 s, 2 s, in the frequency range
|
|
400Hz, 1kHz
|
10kHz-20kHz
|
||
12 months
|
200uA
|
± [1 +0,25 (I a / I-1)]%
|
± [3 +0,3 (I a / I-1)]%
|
2mA
|
± [1 +0,25 (I a / I-1)]%
|
± [3 +0,3 (I a / I-1)]%
|
|
20mA
|
± [1 +0,25 (I a / I-1)]%
|
± [3 +0,3 (I a / I-1)]%
|
|
200mA
|
± [1 +0,25 (I a / I-1)]%
|
± [3 +0,3 (I a / I-1)]%
|
|
2000mA
|
± [1 +0,25 (I a / I-1)]%
|
± [3 +0,3 (I a / I-1)]%
|
|
10A (with external shunt)
|
± [1,5 +0,15 (I a / I-1)]% in the frequency range 40Hz-2kHz
|
||
24 months
|
200uA
|
± [1,5 +0,5 (I a / I-1)]%
|
± [4 +0,4 (I a / I-1)]%
|
2mA
|
± [1,5 +0,5 (I a / I-1)]%
|
± [4 +0,4 (I a / I-1)]%
|
|
20mA
|
± [1,5 +0,5 (I a / I-1)]%
|
± [4 +0,4 (I a / I-1)]%
|
|
200mA
|
± [1,5 +0,5 (I a / I-1)]%
|
± [4 +0,4 (I a / I-1)]%
|
|
2000mA
|
± [1,5 +0,5 (I a / I-1)]%
|
± [4 +0,4 (I a / I-1)]%
|
|
10A (with external shunt)
|
± [2 +0,2 (I a / I-1)]% in the frequency range 40Hz-2kHz
|
Ranges
|
Bystrodey-consequence
|
The quantization step (number of indications)
|
20 ohms
|
0.1 measurements / a
|
100 micromhos (5 1/2)
|
1izmer / s
|
1 milliohms (4 1/2)
|
|
5izmer / s
|
10 m (3 1/2)
|
|
200 ohms
|
3izmer / s
|
1 milliohms (5 1/2)
|
5izmer / s
|
10 m (4 1/2)
|
|
50izmer / s
|
100 mOhm (3 1/2)
|
|
2 k
|
3izmer / s
|
10 m (5 1/2)
|
5izmer / s
|
100 mOhm (4 1/2)
|
|
50izmer / s
|
1 ohms (3 1/2)
|
|
20 kohms
|
3izmer / s
|
100 mOhm (5 1/2)
|
5izmer / s
|
1 ohms (4 1/2)
|
|
50izmer / s
|
10 ohms (3 1/2)
|
|
200 k
|
3izmer / s
|
1 ohms (5 1/2)
|
5izmer / s
|
10 ohms (4 1/2)
|
|
50izmer / s
|
100 ohms (3 1/2)
|
|
2000 ohms
|
3izmer / s
|
10 ohms (5 1/2)
|
5izmer / s
|
100 ohms (4 1/2)
|
|
10izmer / s
|
1k (3 1/2)
|
|
20 M
|
1izmer / s
|
100 ohms (5 1/2)
|
3izmer / s
|
1k (4 1/2)
|
|
5izmer / s
|
10k (3 1/2)
|
|
200 megohms
|
1izmer / s
|
1k (5 1/2)
|
3izmer / s
|
10K (4 1/2)
|
|
5izmer / s
|
100 ohms (3 1/2)
|
Ranges
|
Maximum permissible error for calibration interval
|
|
24h
|
6 months
|
|
20 ohms
|
± [0,025 +0,01 (R a / R-1)]%
|
± [0,04 +0,015 (R a / R-1)]%
|
± [0,025 +0,02 (R a / R-1)]%
|
± [0,04 +0,015 (R a / R-1)]%
|
|
± [0,1 +0,1 (R a / R-1)]%
|
± [0,15 +0,1 (R a / R-1)]%
|
|
200 ohms
|
± [0,015 +0,005 (R a / R-1)]%
|
± [0,025 +0,005 (R a / R-1)]%
|
± [0,02 +0,01 (R a / R-1)]%
|
± [0,03 +0,01 (R a / R-1)]%
|
|
± [0,1 +0,1 (R a / R-1)]%
|
± [0,15 +0,1 (R a / R-1)]%
|
|
2 k
|
± [0,015 +0,0025 (R a / R-1)]%
|
± [0,025 +0,0025 (R a / R-1)]%
|
± [0,02 +0,01 (R a / R-1)]%
|
± [0,025 +0,01 (R a / R-1)]%
|
|
± [0,1 +0,1 (R a / R-1)]%
|
± [0,15 +0,1 (R a / R-1)]%
|
|
20 kohms
|
± [0,015 +0,0025 (R a / R-1)]%
|
± [0,025 +0,0025 (R a / R-1)]%
|
± [0,02 +0,01 (R a / R-1)]%
|
± [0,025 +0,01 (R a / R-1)]%
|
|
± [0,1 +0,1 (R a / R-1)]%
|
± [0,15 +0,1 (R a / R-1)]%
|
|
200 k
|
± [0,015 +0,0025 (R a / R-1)]%
|
± [0,02 +0,0025 (R a / R-1)]%
|
± [0,02 +0,01 (R a / R-1)]%
|
± [0,025 +0,01 (R a / R-1)]%
|
|
± [0,1 +0,1 (R a / R-1)]%
|
± [0,15 +0,1 (R a / R-1)]%
|
|
2000 ohms
|
± [0,02 +0,003 (R a / R-1)]%
|
± [0,03 +0,003 (R a / R-1)]%
|
± [0,04 +0,01 (R a / R-1)]%
|
± [0,05 +0,01 (R a / R-1)]%
|
|
± [0,1 +0,1 (R a / R-1)]%
|
± [0,15 +0,1 (R a / R-1)]%
|
|
20 M
|
± [0,04 +0,004 (R a / R-1)]%
|
± [0,06 +0,004 (R a / R-1)]%
|
± [0,1 +0,01 (R a / R-1)]%
|
± [0,15 +0,01 (R a / R-1)]%
|
|
± [0,15 +0,1 (R a / R-1)]%
|
± [0,15 +0,1 (R a / R-1)]%
|
|
200 megohms
|
± [0,3 +0,1 (R a / R-1)]%
|
± [0,3 +0,1 (R a / R-1)]%
|
± [1,0 +0,1 (R a / R-1)]%
|
± [1,0 +0,1 (R a / R-1)]%
|
|
± [3 +0,1 (R a / R-1)]%
|
± [3 +0,1 (R a / R-1)]%
|
Table 1.12 Maximum permissible error of measurement of electrical resistance
Ranges
|
Bystrodey-consequence
|
The quantization step (number of indications)
|
20 ohms
|
0.1 measurements / a
|
100 micromhos (5 1/2)
|
1izmer / s
|
1 milliohms (4 1/2)
|
|
5izmer / s
|
10 m (3 1/2)
|
|
200 ohms
|
3izmer / s
|
1 milliohms (5 1/2)
|
5izmer / s
|
10 m (4 1/2)
|
|
50izmer / s
|
100 mOhm (3 1/2)
|
|
2 k
|
3izmer / s
|
10 m (5 1/2)
|
5izmer / s
|
100 mOhm (4 1/2)
|
|
50izmer / s
|
1 ohms (3 1/2)
|
|
20 kohms
|
3izmer / s
|
100 mOhm (5 1/2)
|
5izmer / s
|
1 ohms (4 1/2)
|
|
50izmer / s
|
10 ohms (3 1/2)
|
|
200 k
|
3izmer / s
|
1 ohms (5 1/2)
|
5izmer / s
|
10 ohms (4 1/2)
|
|
50izmer / s
|
100 ohms (3 1/2)
|
|
2000 ohms
|
3izmer / s
|
10 ohms (5 1/2)
|
5izmer / s
|
100 ohms (4 1/2)
|
|
10izmer / s
|
1k (3 1/2)
|
|
20 M
|
1izmer / s
|
100 ohms (5 1/2)
|
3izmer / s
|
1k (4 1/2)
|
|
5izmer / s
|
10k (3 1/2)
|
|
200 megohms
|
1izmer / s
|
1k (5 1/2)
|
3izmer / s
|
10K (4 1/2)
|
|
5izmer / s
|
100 ohms (3 1/2)
|
Ranges
|
Maximum permissible error for calibration interval
|
|
24h
|
24 months
|
|
20 ohms
|
± [0,04 +0,015 (R a / R-1)]%
|
± [0,06 +0,025 (R a / R-1)]%
|
± [0,04 +0,02 (R a / R-1)]%
|
± [0,06 +0,04 (R a / R-1)]%
|
|
± [0,15 +0,1 (R a / R-1)]%
|
± [0,25 +0,15 (R a / R-1)]%
|
|
200 ohms
|
± [0,003 +0,005 (R a / R-1)]%
|
± [0,05 +0,005 (R a / R-1)]%
|
± [0,03 +0,01 (R a / R-1)]%
|
± [0,05 +0,01 (R a / R-1)]%
|
|
± [0,15 +0,1 (R a / R-1)]%
|
± [0,25 +0,15 (R a / R-1)]%
|
|
2 k
|
± [0,025 +0,0025 (R a / R-1)]%
|
± [0,04 +0,004 (R a / R-1)]%
|
± [0,025 +0,01 (R a / R-1)]%
|
± [0,04 +0,015 (R a / R-1)]%
|
|
± [0,15 +0,1 (R a / R-1)]%
|
± [0,25 +0,1 (R a / R-1)]%
|
|
20 kohms
|
± [0,025 +0,0025 (R a / R-1)]%
|
± [0,04 +0,004 (R a / R-1)]%
|
± [0,25 +0,01 (R a / R-1)]%
|
± [0,04 +0,01 (R a / R-1)]%
|
|
± [0,15 +0,1 (R a / R-1)]%
|
± [0,25 +0,15 (R a / R-1)]%
|
|
200 k
|
± [0,025 +0,0025 (R a / R-1)]%
|
± [0,04 +0,004 (R a / R-1)]%
|
± [0,025 +0,01 (R a / R-1)]%
|
± [0,04 +0,01 (R a / R-1)]%
|
|
± [0,15 +0,1 (R a / R-1)]%
|
± [0,25 +0,15 (R a / R-1)]%
|
|
2000 ohms
|
± [0,05 +0,003 (R a / R-1)]%
|
± [0,1 +0,01 (R a / R-1)]%
|
± [0,05 +0,01 (R a / R-1)]%
|
± [0,1 +0,015 (R a / R-1)]%
|
|
± [0,15 +0,1 (R a / R-1)]%
|
± [0,25 +0,1 (R a / R-1)]%
|
|
20 M
|
± [0,1 +0,004 (R a / R-1)]%
|
± [0,2 +0,02 (R a / R-1)]%
|
± [0,15 +0,01 (R a / R-1)]%
|
± [0,25 +0,02 (R a / R-1)]%
|
|
± [0,15 +0,1 (R a / R-1)]%
|
± [0,25 +0,15 (R a / R-1)]%
|
|
200 megohms
|
± [0,4 +0,1 (R a / R-1)]%
|
± [0,6 +0,2 (R a / R-1)]%
|
± [1,5 +0,1 (R a / R-1)]%
|
± [2 +0,2 (R a / R-1)]%
|
|
± [4 +0,1 (R a / R-1)]%
|
± [5 +0,2 (R a / R-1)]%
|
Table. 1.11, 1.12, and on the following notation:
Ranges
|
Amperage
|
20 ohms
|
1mA ± 0,2 mA
|
200 ohms
|
1mA ± 0,2 mA
|
2 k
|
1mA ± 0,2 mA
|
20 kohms
|
0.1 mA ± 0,02 mA
|
200 k
|
1mA ± 0,2 mA
|
2000 ohms
|
1mA ± 0,2 mA
|
The maximum value of the DC voltage to the measured resistance (voltage on the open sockets) not more than 10 V when measured at a range of measurements outside the 20 MW, 200 MW less than 2.1 V;
Leading online store Zapadpribor - a huge selection of measuring equipment for the best value and quality. So you can buy inexpensive devices, we monitor competitors' prices and are always ready to offer a lower price. We only sell quality products at the best prices. On our site you can buy cheaply as the latest innovations and proven equipment from the best manufacturers.
The site includes a special offer «buy at the best price» - if other Internet resources (bulletin board, forum or announcement of another online service) in products presented on our site, the lower price, we will sell it to you even cheaper! Buyers also additional discount for leaving a review or photo of use of our products.
In the price list contains not the whole range of products offered. Prices of goods, not included in the price list can learn to contact the manager. Also, our managers You can get detailed information about how cheap and profitable to buy instrumentation wholesale and retail. Telephone and e-mail for advice on the purchase , delivery or receipt are shown on the description of the goods. We have the most qualified staff, quality equipment and the best price.
Online store Zapadpribor - the official manufacturer's dealer test equipment. Our goal - selling high quality goods with best price offer and service to our customers. Our store can not only sell you the necessary instrument, but also offer additional services to its calibration, repair and installation. That you have a pleasant experience when shopping on our site, we have provided special gifts guaranteed to the most popular products.
We offer fast international shipping to almost every country in the world: Australia, Austria, Azerbaijan, Albania, Algeria, Anguilla, Angola, Antigua and Barbuda, Argentina, Aruba, Bahamas, Bangladesh, Barbados, Bahrain, Belize, Belgium, Benin, Bermuda, Bulgaria, Bolivia, Bonaire, Sint-E. and Saba, Bosnia and Herzegovina, Botswana, Brazil, British Virgin Islands, Brunei Darussalam, Burkina Faso, Burundi, Bhutan, VietNam, Vanuatu, Vatican City, Venezuela, Armenia, Gabon, Guyana, Haiti, Gamia, Gambia, Ghana, Guatemala, Guinea, Gibraltar, Honduras, Hong Kong, Grenada, Greenland, Greece, Georgia, Denmark, Democratic Republic of the Congo, Jersey, Djibouti, Dominica, Dominican Republic, Ecuador, Eswatine, Estonia, Ethiopia, Egypt, Zambia, Zimbabwe, Jordan Indonesia, Ireland, Iceland, Spain, Italy, Cape Verde, Kazakhstan, Cayman Islands, Cambodia, Cameroon, Canada, Qatar, Kenya, Kyrgyzstan, China, Cyprus, Kiribati, Colombia, Comoros, Congo, Korea (Rep.), Costa Rica, Kot-d'Ivoire, Cuba, Kuwait, Curacao, Laos, Latvia, Lesotho, Lithuania, Liberia, Lebanon, Libya, Liechtenstein, Luxembourg, Myanmar, Mauritius, Mauritania, Madagascar, Macao, Malawi, Malaysia, Mali, Maldives, Malta, Morocco, Mexico, Mozambique, Moldova, Monaco, Monaco, Namibia, Nauru, Nepal, Niger, Nigeria, Netherlands, Germany, New Zealand, New Caledonia, Norway, UAE, Oman, Cook Islands, Pakistan, Palestine, Panama, Papua New Guinea, Paraguay, Peru, South Africa, Poland, Portugal, Republic of Chad, Rwanda, Romania, El Salvador, Samoa, San Marino, Saudi Arabia, Swaziland, Seychelles, Senegal, Saint Vincent and the Grenadines, Saint Kitts and Nevis, Saint Lucia, Serbia, Singapore, Sint Maarten, Slovakia, Slovenia, Solomon Islands, United Kingdom of Great Britain and Northern Ireland, Sudan, Suriname, East Timor (Timor-Leste), USA, Sierra Leone, Tajikistan, Taiwan, Thailand, Tanzania (United Republic of), Togo, Tonga, Trinidad and Tobago, Tuvalu, Tunisia, Turkey, Turkmenistan, Uganda, Hungary, Uzbekistan, Uruguay, Faroe Islands, Fiji, Philippines, Finland, France, French Polynesia, Croatia, Central African Republic, Czech Republic, Chile, Montenegro, Switzerland, Sweden, Sri Lanka, Jamaica, Japan.
We also provide such metrological procedure: calibration, tare, graduated, testing of measuring instruments.
The online store takes an active part in such procedures as electronic bidding, tender, auction.
If there is no site in the descriptive information you need on the device you can always turn to us for help. Our qualified managers will update for you on the technical characteristics of the device from its technical documentation: user manual, certificate, form, operating instructions, diagram. If necessary, we will take a photo of your device, or a device stand. You can leave feedback on the unit purchased from us, the meter, the device, indicator, or product. Your review for your approval will be published on the site without contact information.
Description of the instruments taken from the technical documentation or technical literature. Most pictures of products made directly by our experts prior to shipment of goods. In the description of the device provided the main technical characteristics of the instrument: nominal measuring range, accuracy class, scale, supply voltage, size (size), weight. If the site you see the discrepancy device name (model) specifications, photo or documents attached - let us know - you will get a useful gift with-selling device.
While the need to clarify the overall weight and size or the size of the individual meter you can in our service center. If you need our engineers will help you choose the most complete analog or a suitable replacement for the device you are interested. All counterparts and replacement will be tested in one of our laboratories with the full compliance to your requirements.
In the technical documentation for each device or product, information is provided on the list and amount of precious metals content. The documentation gives the exact weight in grams of precious metals: Au gold, palladium Pd, platinum Pt, silver Ag, tantalum Ta and other platinum group metals (PGM) per unit item. These precious metals are found in nature in very limited quantities and therefore have such a high price.
On our website you can familiarize yourself with the technical characteristics of devices and obtain information on the content of precious metals in devices and radio components manufactured in the USSR. We draw your attention to the fact that often the actual content of precious metals differs by 10-25% from the reference one in a smaller direction! The price of precious metals will depend on their value and mass in grams.
All text and graphic information on the site is informative. The color, shade, material, geometric dimensions, weight, content, delivery set and other parameters of the goods presented on the site may vary depending on the batch of production and year of manufacture. Check with the sales department for more information.
If you can make repairs to the device yourself, our engineers can provide you with a complete set of necessary technical documentation: circuit diagram TO, ER, FD, PS. We also have an extensive database of technical and metrological documents: technical specifications (TS), the terms of reference (TOR), GOST (DSTU), the industry standard (OST) test procedure, the method of certification, verification scheme for more than 3,500 types of measuring equipment from the manufacturer this equipment. From the site you can download all the necessary software (the software driver) is required for the product purchased.
We carries out repairs and maintenance of measuring equipment in more than 75 different factories of the former Soviet Union and CIS.
We also have a library of legal documents that are related to our field of activity: the law, code, ordinance, decree, temporary position.