V6-10 V6-10
4.9 63

Microvoltmeter selective V6-10 (V610, V6 10, b6-10, b610, b6 10)
Measurement of rms sinusoidal voltages and study the spectrum of periodic signals, the query translation of AC voltage to DC voltage.
Voltage measurement range: 1mkV - 10mV (in the narrow bandwidth of 1 kHz); 3mkV - 10mV (at wide bandwidth 9 kHz), 10mV - 1V (with voltage divider 1:100).
Frequency range of the measured voltages of 0.1-30MHz.
Measurement error of ± (10-15)%. Bx. Pair. 2 MW (100 kHz, 3mkV-10mV) input. cap. 10pF.

V6-10 microvoltmeter image.

Price:

on request

 

Product information updated 08 October 2024.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

print

Product information updated 08 October 2024.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

print

Technical characteristics

Microvoltmeter selective V6-10 (V610, V6 10, b6-10, b610, b6 10)
Measurement of rms sinusoidal voltages and study the spectrum of periodic signals, the query translation of AC voltage to DC voltage.
Voltage measurement range: 1mkV - 10mV (in the narrow bandwidth of 1 kHz); 3mkV - 10mV (at wide bandwidth 9 kHz), 10mV - 1V (with voltage divider 1:100).
Frequency range of the measured voltages of 0.1-30MHz.
Measurement error of ± (10-15)%. Bx. Pair. 2 MW (100 kHz, 3mkV-10mV) input. cap. 10pF.

 

Microvoltmeter selective V6-10 designed to measure the rms values ​​of sinusoidal voltages and study the spectrum of periodic signals in the laboratory and shop floor.

 

Operating conditions:
the ambient temperature of 283 K (10 ° C) to 308 K (35 ° C);
relative humidity up to 80% at a temperature of 298 K (25 ° C), atmospheric pressure (86-106) kPa (650-800) mm Hg. Art.;
voltage of 220 ± 22 V, ± 0,5 at 50 Hz and harmonic content up to 5%.
The possibility of the device Microvoltmeter selective V6-10 with selective CPC (Channel obscheyu use) and AIS (automated measuring system) is not provided.
Technical data
The range of measured Microvoltmeter V6-10 1mkV voltages from 10mV to a narrow bandwidth of 1 kHz and 3mkV to 10mV over a wide bandwidth of 9 kHz sub-bands overlap with upper limits 3mkV; 10mkV; 30mkV; 100mkV; 300mkV; 1 mV; 3mV; 10mV.
With a voltage divider 1:100 YAY2.727.076 range of measured Microvoltmeter V6-10 voltages above 10 mV to 1V is provided on ranges with upper limits from 300 mV to 10 mV.
With a voltage divider 1:10 YAY2.727.075 range of measured Microvoltmeter V6-10 voltages above 10 mV to 100 mV should be provided at ranges with upper limits of 1 mV to 10 mV.
The range of frequencies measured Microvoltmeter V6-10 strains from 0.1 to 30 MHz sub-bands overlap:
0.1 to 0.3 MHz, 3 MHz to 10;
from 0.3 to 1 MHz 10 to 20 MHz;
from 1 to 3 MHz to 20 MHz to 30 MHz.
Cruising on the edges of the frequency range and overlap in frequency sub-bands at least twice the error of the frequency and the value of frequency setting error, respectively.
Frequency of calibration of 1 MHz ± 5%.
Frequency range is divided into normal and two workspaces. Normal work area - 0.3 MHz to 1 MHz inclusive. The first work area - from 0.1 MHz to 0.3 MHz inclusive. The second work area - from 1MHz to 30MHz.
Output accuracy microvoltmeter V6-10 in the normal range of frequencies under normal conditions at a frequency of calibration, expressed as a percentage of the upper limit of the established sub-band measurements must be:
- With a narrow bandwidth:
± 6% for ranges with upper limits of measurement 10mkV to 1B;
± 10% for the sub-band with the upper limit of measurement 3mkV;
- With wide bandwidth: ± 6% for ranges with upper limits of measurement 30mkV to 1B.
± 10% for the sub-band with an upper limit of 10 mV measurements.
Limits of error microvoltmeter in all work areas, expressed as a percentage of the upper limit of the established sub-band measurements in normal conditions, does not exceed:
- With a narrow bandwidth:
± 10% for the sub-bands with the upper, outside measurement of 10mkV to 1B;
± 15% for sub-band with the upper limit of measurement 3 mV;
- With broad bandwidths:
± 10% for the sub-bands with upper limits of measurement 30mkV to 1B;
± 15% for sub-bands with the upper limit of measurement 10mkV.
Note. The value of the influencing factors in normal conditions of use and permissible deviations from them must comply with:
- The temperature of the ambient air    (20 ± 5) ° C;
- Relative humidity: 30-80%;
- Atmospheric pressure 84-106.7 kPa (630-800 mm Hg. Centuries).
- Absence of external electric and magnetic fields other than the earth magnetic field;
- Supply voltage alternating current (220 ± 11) V, (50 ± 0,5) Hz harmonic form with a coefficient of harmonics does not exceed 5%.
Changes display microvoltmeter V6-10 as a percentage of readings at a frequency of calibration in all work areas of frequencies should not exceed:
± (5 +0,1 f)% for ranges with upper limits of measurement: 10mkV for bandwidth; 3mkV for low bandwidth;
± (4 +0,1 f)% in the rest of sub-bands measurements for narrow and wide bandwidths, where f - frequency in MHz.
Note. When measuring the basic error allowed fluctuation index indicating device that does not exceed:
- In a narrow band    transmission:
± 5% for ranges with upper limits of measurement 30mkV to 1B; ± 10% ranges with upper limits of measurement 3mkV to 10 mV, in    wide bandwidth:
± 5% for ranges with upper limits of measurement 100mkV to 1B;
± 10% for the sub-bands with upper limits of measurement 10mkV to 30mkV.
Additional instrument error V6-10, due to the change of ambient temperature from normal to any temperature within the operating temperature range does not exceed half of the value of basic error for every 10 ° C change in temperature. Shape factor of the resonance characteristics microvoltmeter no more than three.
Microvoltmeter selective V6-10 has an output intermediate frequency amplifier and provides an output voltage of 1 ± 0,2 V (for rejecting a pointer to the final mark of the scale) frequency of 250 kHz with a load of at least 100 kW.
The output voltage of the inverter (U O), an AC voltage into a DC voltage when the input voltage is subbands upper limits of the load measuring not less than 100 ohms should be 1V.
Error of the output voltage of the converter at the input does not exceed the basic error microvoltmeter above.
The noise floor microvoltmeter V6-10 does not exceed:
in low bandwidth mode 0.7mV per sub-band with the upper limit of measurement 3mkV;
in the wide bandwidth by 2 mV upper limit subband 10mkV measurement.
Error of frequency as a percentage of the measured frequency is less than the value calculated by the formula:
δ f = ± (5 + 500 / f), (1)
where f - frequency in kHz;
δ f - error of frequency.
Bandwidth level - 3dB:
narrow bandwidth mode - 1 ± 0,2 kHz;
in the wide bandwidth mode - 9 ± 0,9 kHz.
Attenuation mirror channels at frequencies not less than 60 dB.
Attenuation at frequencies equal to the intermediate, at least 50 dB.
The level of internal Raman signals to be less than 2 mV.
The weakening of signals at frequencies of side channel unit is not less than 50 dB.
Level own distortion at signal input probe is not more than 10 mV less than - 50 dB.
Microvoltmeter active input impedance, measured at a frequency of 100 kHz, a minimum of 2 MW at ranges with upper limits of 3mkV to 10mV. Input capacitance microvoltmeter with a divider and without 1:100 does not exceed 10 pF.
The output impedance of the amplifier intermediate frequency of 600 ± 120 ohms. Output impedance converter AC voltage into a DC voltage 1 ± 0,2 kohm.
Response time microvoltmeter does not exceed 4. The maximum deviation of the index from the steady readings in the transition process when applied to the input voltage of 0.7 sub-band upper limit value does not exceed the upper limit of the sub-band measurements.
The level of permissible DC voltage at the input microvoltmeter should not exceed 100 V.
Microvoltmeter selective V6-10 meets its specifications after a setup time of 15 minutes.
Microvoltmeter selective V6-10 retains its specifications when powered from the mains AC voltage of 220 ± 11 V, ± 0,5 at 50 Hz and harmonic content up to 5%.
Power consumed Microvoltmeter from the network, at the rated voltage does not exceed 55 VA.
Microvoltmeter selective V6-10 allows continuous operation under the operating conditions for 8 hours while maintaining their performance. Time interval before re-starting after continuous operation must be at least 15 minutes. Mean time between failures (T avg) at least 7,000 hours Dimensions microvoltmeter 490x215x355 mm. Weight microvoltmeter not more than 25 kg.
Rate the product: V6-10
Number of views: 1687
Product rating: 4.5
Number of grades: 432
* rating and all product statistics are updated once a month; information is current as of 19 October 2024

Photos: V6-10

V6-10 microvoltmeter image.

V6-10 microvoltmeter image.

V6-10 front view.

V6-10 front view.

V6-10 side view.

V6-10 side view.

V6-10 rear view.

V6-10 rear view.

V6-10 overhead view.

V6-10 overhead view.

V6-10 bottom view.

V6-10 bottom view.

Leading online store Zapadpribor - a huge selection of measuring equipment for the best value and quality. So you can buy inexpensive devices, we monitor competitors' prices and are always ready to offer a lower price. We only sell quality products at the best prices. On our site you can buy cheaply as the latest innovations and proven equipment from the best manufacturers.

The site includes a special offer «buy at the best price» - if other Internet resources (bulletin board, forum or announcement of another online service) in products presented on our site, the lower price, we will sell it to you even cheaper! Buyers also additional discount for leaving a review or photo of use of our products.

In the price list contains not the whole range of products offered. Prices of goods, not included in the price list can learn to contact the manager. Also, our managers You can get detailed information about how cheap and profitable to buy instrumentation wholesale and retail. Telephone and e-mail for advice on the purchase , delivery or receipt are shown on the description of the goods. We have the most qualified staff, quality equipment and the best price.

 

Online store Zapadpribor - the official manufacturer's dealer test equipment. Our goal - selling high quality goods with best price offer and service to our customers. Our store can not only sell you the necessary instrument, but also offer additional services to its calibration, repair and installation. That you have a pleasant experience when shopping on our site, we have provided special gifts guaranteed to the most popular products.

 

We offer fast international shipping to almost every country in the world: Australia, Austria, Azerbaijan, Albania, Algeria, Anguilla, Angola, Antigua and Barbuda, Argentina, Aruba,  Bahamas, Bangladesh, Barbados, Bahrain, Belize, Belgium, Benin, Bermuda, Bulgaria, Bolivia, Bonaire, Sint-E. and Saba, Bosnia and Herzegovina, Botswana, Brazil, British Virgin Islands, Brunei Darussalam, Burkina Faso, Burundi, Bhutan, VietNam, Vanuatu, Vatican City, Venezuela, Armenia, Gabon, Guyana, Haiti, Gamia, Gambia, Ghana, Guatemala, Guinea, Gibraltar, Honduras, Hong Kong, Grenada, Greenland, Greece, Georgia, Denmark, Democratic Republic of the Congo, Jersey, Djibouti, Dominica, Dominican Republic, Ecuador, Eswatine, Estonia, Ethiopia, Egypt, Zambia, Zimbabwe, Jordan Indonesia, Ireland, Iceland, Spain, Italy, Cape Verde, Kazakhstan, Cayman Islands, Cambodia, Cameroon, Canada, Qatar, Kenya, Kyrgyzstan, China, Cyprus, Kiribati, Colombia, Comoros, Congo, Korea (Rep.), Costa Rica, Kot-d'Ivoire, Cuba, Kuwait, Curacao, Laos, Latvia, Lesotho, Lithuania, Liberia, Lebanon, Libya, Liechtenstein, Luxembourg, Myanmar, Mauritius, Mauritania, Madagascar, Macao, Malawi, Malaysia, Mali, Maldives, Malta, Morocco, Mexico, Mozambique, Moldova, Monaco, Monaco, Namibia, Nauru, Nepal, Niger, Nigeria, Netherlands, Germany, New Zealand, New Caledonia, Norway, UAE, Oman, Cook Islands, Pakistan, Palestine, Panama, Papua New Guinea, Paraguay, Peru, South Africa, Poland, Portugal, Republic of Chad, Rwanda, Romania, El Salvador, Samoa, San Marino, Saudi Arabia, Swaziland, Seychelles, Senegal, Saint Vincent and the Grenadines, Saint Kitts and Nevis, Saint Lucia, Serbia, Singapore, Sint Maarten, Slovakia, Slovenia, Solomon Islands, United Kingdom of Great Britain and Northern Ireland, Sudan, Suriname, East Timor (Timor-Leste), USA, Sierra Leone, Tajikistan, Taiwan, Thailand, Tanzania (United Republic of), Togo, Tonga, Trinidad and Tobago, Tuvalu, Tunisia, Turkey, Turkmenistan, Uganda, Hungary, Uzbekistan, Uruguay, Faroe Islands, Fiji, Philippines, Finland, France, French Polynesia, Croatia, Central African Republic, Czech Republic, Chile, Montenegro, Switzerland, Sweden, Sri Lanka, Jamaica, Japan.

We also provide such metrological procedure: calibration, tare, graduated, testing of measuring instruments.

The online store takes an active part in such procedures as electronic bidding, tender, auction.

If there is no site in the descriptive information you need on the device you can always turn to us for help. Our qualified managers will update for you on the technical characteristics of the device from its technical documentation: user manual, certificate, form, operating instructions, diagram. If necessary, we will take a photo of your device, or a device stand. You can leave feedback on the unit purchased from us, the meter, the device, indicator, or product. Your review for your approval will be published on the site without contact information.

 

Description of the instruments taken from the technical documentation or technical literature. Most pictures of products made directly by our experts prior to shipment of goods. In the description of the device provided the main technical characteristics of the instrument: nominal measuring range, accuracy class, scale, supply voltage, size (size), weight. If the site you see the discrepancy device name (model) specifications, photo or documents attached - let us know - you will get a useful gift with-selling device.

 

While the need to clarify the overall weight and size or the size of the individual meter you can in our service center. If you need our engineers will help you choose the most complete analog or a suitable replacement for the device you are interested. All counterparts and replacement will be tested in one of our laboratories with the full compliance to your requirements.

In the technical documentation for each device or product, information is provided on the list and amount of precious metals content. The documentation gives the exact weight in grams of precious metals: Au gold, palladium Pd, platinum Pt, silver Ag, tantalum Ta and other platinum group metals (PGM) per unit item. These precious metals are found in nature in very limited quantities and therefore have such a high price.

On our website you can familiarize yourself with the technical characteristics of devices and obtain information on the content of precious metals in devices and radio components manufactured in the USSR. We draw your attention to the fact that often the actual content of precious metals differs by 10-25% from the reference one in a smaller direction! The price of precious metals will depend on their value and mass in grams.

All text and graphic information on the site is informative. The color, shade, material, geometric dimensions, weight, content, delivery set and other parameters of the goods presented on the site may vary depending on the batch of production and year of manufacture. Check with the sales department for more information.

 

If you can make repairs to the device yourself, our engineers can provide you with a complete set of necessary technical documentation: circuit diagram TO, ER, FD, PS. We also have an extensive database of technical and metrological documents: technical specifications (TS), the terms of reference (TOR), GOST (DSTU), the industry standard (OST) test procedure, the method of certification, verification scheme for more than 3,500 types of measuring equipment from the manufacturer this equipment. From the site you can download all the necessary software (the software driver) is required for the product purchased.

We carries out repairs and maintenance of measuring equipment in more than 75 different factories of the former Soviet Union and CIS.

We also have a library of legal documents that are related to our field of activity: the law, code, ordinance, decree, temporary position.