S1-104 S1-104
4.9 63
Oscilloscope S1-104 Universal (S1104, S-1-104, S 1104, S1-104, S-1104, S 1104, S1 104, S1104, c-1-104, c 1104, c-1104, c 1104 , c1 104)
Intended for visual observation and measurement of single and periodic electrical processes in the frequency range from DC to 500MHz by:
- Measurement of amplitude and time parameters of the signal in the range from 0.04 V to 8 V, with external divider 1:10 - 10V, with active probes - up to 24 and the time intervals in the range of 4 ∙ 10 -9 s to 0.5 s;
- Simultaneous images of the two investigated signals on a single scan;
Class of accuracy of the oscilloscope - 2;
The dimensions of the working of the screen - 80h100mm.
Radiometric devices
oscilloscopes (S1-, S7-, S8-, S9-, Ya40-, Ya4S-, Ya9S- and others)
S1-104 oscilloscope image.

Price:

on request

 

Product information updated 04 December 2024.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

print

Product information updated 04 December 2024.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

print

Technical characteristics

Oscilloscope S1-104 Universal (S1104, S-1-104, S 1104, S1-104, S-1104, S 1104, S1 104, S1104, c-1-104, c 1104, c-1104, c 1104 , c1 104)
 
Oscilloscope S1-104 is designed for universal visual observation and measurement of single and periodic electrical processes in the frequency range from DC to 500MHz by:
- Measurement of amplitude and time parameters of the signal in the range from 0.04 V to 8 V, with external divider 1:10 - 10V, with active probes - up to 24 and the time intervals in the range of 4 ∙ 10 -9 s to 0.5 s;
- Simultaneous images of the two investigated signals on a single scan;
Oscilloscope S1-104 Universal is designed to work in the laboratory and workshop conditions and can be used for research, calibration and repair.
 
Technical characteristics of the devices Oscilloscope S1-104 universal:
 
Operating conditions:
- Ambient temperature - from +5 ° C to +40 ° C;
- Relative humidity - less than 95% at +30 º C ± 2 ° C;
- Atmospheric pressure - from 61,3 ∙ 10 3 Pa to 106,6 ∙ 10 3 Pa (from 460 mm Hg. Art. Up to 800 mm Hg. Art.);
- Mains voltage 220V ± 22V 50Hz ± 1Hz or 220V ± 11V, 115V ± 5,75 in the frequency of 400 Hz ± 12Gts;
Power off the device oscilloscope S1-104 universal resistance to cyclic changes in ambient temperature from -50 ° C to +60 ° C;
Packaged in a laying box and containerboard oscilloscope withstand mechanical impact:
- Multiple shocks with acceleration up to 15g and a pulse duration of 5 ms to 10 ms;
- A single stroke, with acceleration up to 75g and a pulse duration of 1 ms to 4 ms;
Normal operating conditions the instrument oscilloscope S1-104 universal:
- Ambient temperature - 20 ° C ± 5 º C;
- Relative humidity - 65% ± 15%;
- Atmospheric pressure - 100kPa ± 4kPa (750mm.rt.st. ± 30mm.rt.st.);
- Mains voltage:
- 220 ± 4,4 V for the network with a frequency of 50 Hz ± 0,1 Hz;
- 220 ± 4,4 V or 115 V ± 2,5 V for the network with a frequency of 400 Hz ± 12Gts and harmonic content up to 5%;
Class of accuracy of the oscilloscope - 2;
The dimensions of the working side of the screen device oscilloscope S1-104 universal:
- Vertical - 80mm (8 points);
- Horizontal - 100mm (10 points);
The line width of the beam - no more than 0.8 mm;
Limits of error in the calibrated deflection factor: 0.01 V / div, 0.02 V / div, 0.05 V / div and 0.1 V / div and 0.2 V / div and 0.5 V / div and vertical 1V/del should be ± 4%;
Limits of error coefficient of variation in working conditions must be ± 6%;
Maximum permissible errors of the coefficients of deviation device oscilloscope S1-104 universal with 1:10 divider and an active probe I22.746.036 should be ± 10%;
Step response time of both channels of a vertical deviation is less than 0.8 ns;
Step response time with an active probe and remote I22.746.036 1:10 divider is less than 1 ns I22.727.082;
Emission characteristics of a transitional channel vertical deflection does not exceed 10%;
Emission characteristics of the transition to the active channel and the external probe I22.746.036 I22.727.082 1:10 divider does not exceed 10%;
The time for establishing the transient response channels of the oscilloscope vertical deflection device S1-104 universal oscilloscope with 1:10 divider and an oscilloscope I22.727.082 with an active probe is less than 4ns I22.746.036;
The uneven transition channel performance in vertical position in the area from 4ns to 10ns should not exceed ± 10%, in the area from 10ns to 100ns - ± 3% after 100 ns - ± 2%;
The uneven transition characteristics of the instrument oscilloscope S1-104 universal remote with 1:10 divider and an active probe I22.727.082 I22.746.036 should not exceed ± 10% of the area from 4ns to 10ns, ± 4% of the area from 10 ns to 100 ns and ± 3% after 100 ns.The decline in the top of the transient response of closed channels at the inputs of test pulse duration 5mks not exceed 10%;
The displacement of the beam due to zero drift amplifier channel vertical deflection after 15 minutes of warm-up shall not exceed:
- 10 mV (1 cases) for 1 hour (long-term drift);
- 2 mV (0.2 cases) within 1 minute of work (short-term drift);
The displacement of the beam oscilloscope universal instrument S1-104 when the mains voltage ± 10% less than 2 mV (0.2 cases);
The displacement of the beam due to the input current amplifier channel vertical deflection not exceeding 5mV (0, 5 cases);
Periodic and (or) random deviations should be no more than 2% of the nominal value;
Limits of movement in the vertical beam is at least two dimensions of the working side of the screen vertically;
The input resistance of channel oscilloscope vertical deflection device S1-104 universal with open entrances is 50 ohms ± 1 ohm;
Input impedance divider 1:10 I22.727.082 remote is 500 ohms ± 10 ohms;
Input impedance with an active probe I22.746.036 is 100K ± 5 ohms and the input capacitance of no more than 7.5 pF;
Restricted to the total value of the DC and AC voltages on closed "~" input channel oscilloscope vertical deflection device S1-104 universal no more than 20V, and the amplitude of the variable component should not exceed 8V;
The maximum amplitude of the signal or the value of DC voltage inputs on the open "~ -> unit shall not exceed 8V;
The maximum value of AC or DC voltage at the input of the active probe I22.746.033 should not exceed 0.6 V, at the entrance of the active probe I22.746.033 with divisors of 1:4, 1:20; 1:40 - 2.4 V, 12V, 24V, respectively, a remote input divider I22.727.082 - 10V;
The reflection coefficient of the agreed input channels of a vertical deviation of 0.25;
The device is an oscilloscope S1-104 universal provides the following modes of vertical deflection channels:
- Single-channel mode (I, II);
- Alternate mode with a frequency of switching channels, synchronous frequency sweep;
- Intermittent fixed 500kHz switching frequency;
- Algebraic addition mode signal (I + II);
The device is an oscilloscope S1-104 universal provides the following modes of operation of the generator base:
- Self-oscillation;
- Waiting;
- Single run;
Limits of error in the calibrated sweep: 1ns/del, 2ns/del, 5ns/del, 10ns/del, 20ns/del, 50ns/del, 0.1 ms / div, 0.2 ms / div, 0.5 ms / div, 1mks / cases 2mks/del, 5mks/del, 10mks/del, 20mks/del, 50mks/del, 0.1 ms / div, 0.2 ms / div, 0.5 ms / div, 1ms/del, 2ms/del, 5ms / cases 10ms/del, 20ms/del, 50ms/del should be ± 4%;
Oscilloscope sweep unit S1-104 Universal 0.1 V / div, 0.2 s / div, 0.5 s / div is a survey;
Limits of error in the calibrated sweep in working conditions must be ± 6%;
The device is an oscilloscope S1-104 universal provides fine adjustment of the duration of the sweep at each poddiipazone by a factor of the overlap of at least 2.5 times.
Adjustment, moving the beam in the horizontal alignment provides the beginning and end of scan lines from the center of the screen. Moving the beam in the position of the switch "TIME / DIV." - And 1ns/del 2ns/del. should ensure that the combination of the start of the working of the line scan with the center of the screen and moves it to the 10 divisions to the left of center;
Coefficient of variation of the horizontal input «X» is no more than 0.4 V / div;
Channel bandwidth, horizontal deflection 0MGts-1, relative to the reference frequency 0MGts 10kHz;
Input resistance of horizontal deflection channel is 100 ohms with input capacitance 30pF;
Run the scan is carried out on the following clock sources:
- Internal;
- Outer (1:1 and 1:10);
- From the mains;
Frequency range of internal and external synchronization device oscilloscope S1-104 universal, depending on the type of connection to the source is:
- In the position of the switch connection "~" - 50 ∙ 10 3 Hz to 500 ∙ 10 6 Hz; "~ -" - from 20 Hz to 500 ∙ 10 6 Hz;
Internal synchronization device scan oscilloscope S1-104 universal carried out:
- Sinusoidal signals at frequencies from 20 Hz to 100 ∙ 10 6 Hz at the size of the image signal from a division of 8 divisions (from 10mm to 80mm) and in the range from 100 MHz to 500 MHz when the image size from 2.5 to 8 divisions divisions of the scale (from 25mm to 80mm);
- Pulse signals of both polarities duration of 3ns and a repetition frequency of up to 30MHz when the image size of impulses from one division to eight divisions of the scale (from 10mm to 80mm);
- Signals with a frequency of the mains;
External synchronization is sinusoidal signals in a frequency band from 20 MHz ∙ 10 -6 to 500 MHz and pulse duration of 3ns signal and a repetition frequency up to 30MHz and the amplitude of 0.4V to 4V. The instability of the synchronization is less than 0.3 ns;
The active resistance of the external synchronization input "external" device oscilloscope S1-104 universal must be within 50 ohms ± 2 ohms;
Geometric distortion of the image signal at the edges of the working side of the screen shall not exceed: the axis of «X» - 3% on the axis "Y" - 2%;
Orthogonality error deflection on the horizontal and vertical axes should not exceed 2%;
Voltage industrial interference generated by the instrument oscilloscope S1-104 universal, should not exceed:
- 80 dB at frequencies from 0.15 MHz to 0.5 MHz;
- 74dB at frequencies from 0.5 MHz to 2.5 MHz;
- 66dB at frequencies from 2.5 MHz to 30 MHz;
Electrical isolation between the input power supply circuit network cable and the housing unit oscilloscope S1-104 universal must withstand without breakdown for 1 min, the test voltage AC, 50 Hz:
- 1500 V (peak value) in normal conditions;
- 900V (peak value) at high humidity.
The insulation resistance of this circuit device oscilloscope C1-104 universal with respect to housing should be:
- Under normal circumstances at least 20 megohms;
- High humidity should be less than 2 MW;
- At an elevated temperature should be not less than 5 megohms;
Internal power supply shall issue a calibrated positive DC voltage and positive U-shaped pulses with a repetition rate of 1kHz value 0.06 V and 0.6 V into 50 ohms and 500 ohms, respectively;
The margin of error repetition rate, pulse amplitude and the constant voltage device oscilloscope S1-104 universal must not exceed:
- In normal circumstances, ± 1,5%;
- The working conditions ± 2%;
The device provides an output to synchronize external devices: a positive sawtooth voltage amplitude of not less than 2.5 V into two ohms, and a repetition period equal to the period sweep;
Modulation of brightness provides labels for the observation of brightness applied to the input «Z» Instrument oscilloscope S1-104 universal signals in the frequency range from 20Hz to 30 ∙ 10 6 Hz and pulse duration of positive polarity from 50 ns to 50 ms amplitude in the range of 4V to 10V;
Input impedance input «Z» is not less than 1 ohm, and the input capacitance of less than 15pF;
Adjust the brightness of the instrument oscilloscope S1-104 provides a universal change in brightness of the image signal from no to a value suitable for observation;
Adjusting the lighting changes the scale illumination CRT scale from no to his size, convenient for reference;
When you press "SEARCH THE BEAM" the image signal should appear in the operating side of the screen;
The device is an oscilloscope S1-104 universal provides its specifications after heating for 15 minutes;
The power consumed by the device from AC power at nominal voltage not exceeding 170V ∙ A;
The oscilloscope is executed in the desktop version;
Overall dimensions
- Instrument Oscilloscope S1-104 universal - 345X217X494mm;
- The instrument in laying the box - 629H 309H602 mm;
- Container boxes with paving - 753H 439H709 mm;
- Container box apparatusoscilloscope S1-104 universal with a cardboard box - 491X427X881mm.
Weight:
- Unit - no more than 16kg;
- Instrument Oscilloscope S1-104 universal in laying box - should not exceed 36kg;
- The instrument in a packing case box - should not exceed 70kg;
- Instrument Oscilloscope S1-104 Universal Box YAP4-180-074-07 - should be no more than 21kg;
The device retains its specifications within the standards set specifications for power from the mains AC voltage:
- 220V ± 22V 50Hz ± 0,1 Hz harmonic content up to 5%;
- 115V ± 5,75 V and 220 V ± 11 V ± 400 Hz frequency and harmonic content 12Gts to 5%;
The unit maintains its characteristics in continuous operation in the work environment for 8 hours;
Working hours instrument oscilloscope S1-104 Universal to failure - at least 1,000 hours;
The number of switching cycles of switches - no less than 30,000;
Average yield - at least 5,000 hours;
Average life instrument oscilloscope S1-104 universal - at least 5 years;
The device must be kept under the conditions:
- In a heated storage capital at an air temperature of +5 ° C to +25 ° C and relative humidity up to 80% at +25 ° C or lower without condensation;
- In an unheated warehouse capital at an air temperature of -50 ° C to +60 ° C and relative humidity up to 95% at +25 ° C or lower without condensation.
Rate the product: S1-104
Number of views: 2453
Product rating: 4.6
Number of grades: 507
* rating and all product statistics are updated once a month; information is current as of 19 December 2024

Photos: S1-104

S1-104 oscilloscope image.

S1-104 oscilloscope image.

S1-104 front view.

S1-104 front view.

S1-104 side view.

S1-104 side view.

S1-104 rear view.

S1-104 rear view.

S1-104 side view.

S1-104 side view.

S1-104 overhead view.

S1-104 overhead view.

S1-104 bottom view.

S1-104 bottom view.

Leading online store Zapadpribor - a huge selection of measuring equipment for the best value and quality. So you can buy inexpensive devices, we monitor competitors' prices and are always ready to offer a lower price. We only sell quality products at the best prices. On our site you can buy cheaply as the latest innovations and proven equipment from the best manufacturers.

The site includes a special offer «buy at the best price» - if other Internet resources (bulletin board, forum or announcement of another online service) in products presented on our site, the lower price, we will sell it to you even cheaper! Buyers also additional discount for leaving a review or photo of use of our products.

In the price list contains not the whole range of products offered. Prices of goods, not included in the price list can learn to contact the manager. Also, our managers You can get detailed information about how cheap and profitable to buy instrumentation wholesale and retail. Telephone and e-mail for advice on the purchase , delivery or receipt are shown on the description of the goods. We have the most qualified staff, quality equipment and the best price.

 

Online store Zapadpribor - the official manufacturer's dealer test equipment. Our goal - selling high quality goods with best price offer and service to our customers. Our store can not only sell you the necessary instrument, but also offer additional services to its calibration, repair and installation. That you have a pleasant experience when shopping on our site, we have provided special gifts guaranteed to the most popular products.

 

We offer fast international shipping to almost every country in the world: Australia, Austria, Azerbaijan, Albania, Algeria, Anguilla, Angola, Antigua and Barbuda, Argentina, Aruba,  Bahamas, Bangladesh, Barbados, Bahrain, Belize, Belgium, Benin, Bermuda, Bulgaria, Bolivia, Bonaire, Sint-E. and Saba, Bosnia and Herzegovina, Botswana, Brazil, British Virgin Islands, Brunei Darussalam, Burkina Faso, Burundi, Bhutan, VietNam, Vanuatu, Vatican City, Venezuela, Armenia, Gabon, Guyana, Haiti, Gamia, Gambia, Ghana, Guatemala, Guinea, Gibraltar, Honduras, Hong Kong, Grenada, Greenland, Greece, Georgia, Denmark, Democratic Republic of the Congo, Jersey, Djibouti, Dominica, Dominican Republic, Ecuador, Eswatine, Estonia, Ethiopia, Egypt, Zambia, Zimbabwe, Jordan Indonesia, Ireland, Iceland, Spain, Italy, Cape Verde, Kazakhstan, Cayman Islands, Cambodia, Cameroon, Canada, Qatar, Kenya, Kyrgyzstan, China, Cyprus, Kiribati, Colombia, Comoros, Congo, Korea (Rep.), Costa Rica, Kot-d'Ivoire, Cuba, Kuwait, Curacao, Laos, Latvia, Lesotho, Lithuania, Liberia, Lebanon, Libya, Liechtenstein, Luxembourg, Myanmar, Mauritius, Mauritania, Madagascar, Macao, Malawi, Malaysia, Mali, Maldives, Malta, Morocco, Mexico, Mozambique, Moldova, Monaco, Monaco, Namibia, Nauru, Nepal, Niger, Nigeria, Netherlands, Germany, New Zealand, New Caledonia, Norway, UAE, Oman, Cook Islands, Pakistan, Palestine, Panama, Papua New Guinea, Paraguay, Peru, South Africa, Poland, Portugal, Republic of Chad, Rwanda, Romania, El Salvador, Samoa, San Marino, Saudi Arabia, Swaziland, Seychelles, Senegal, Saint Vincent and the Grenadines, Saint Kitts and Nevis, Saint Lucia, Serbia, Singapore, Sint Maarten, Slovakia, Slovenia, Solomon Islands, United Kingdom of Great Britain and Northern Ireland, Sudan, Suriname, East Timor (Timor-Leste), USA, Sierra Leone, Tajikistan, Taiwan, Thailand, Tanzania (United Republic of), Togo, Tonga, Trinidad and Tobago, Tuvalu, Tunisia, Turkey, Turkmenistan, Uganda, Hungary, Uzbekistan, Uruguay, Faroe Islands, Fiji, Philippines, Finland, France, French Polynesia, Croatia, Central African Republic, Czech Republic, Chile, Montenegro, Switzerland, Sweden, Sri Lanka, Jamaica, Japan.

We also provide such metrological procedure: calibration, tare, graduated, testing of measuring instruments.

The online store takes an active part in such procedures as electronic bidding, tender, auction.

If there is no site in the descriptive information you need on the device you can always turn to us for help. Our qualified managers will update for you on the technical characteristics of the device from its technical documentation: user manual, certificate, form, operating instructions, diagram. If necessary, we will take a photo of your device, or a device stand. You can leave feedback on the unit purchased from us, the meter, the device, indicator, or product. Your review for your approval will be published on the site without contact information.

 

Description of the instruments taken from the technical documentation or technical literature. Most pictures of products made directly by our experts prior to shipment of goods. In the description of the device provided the main technical characteristics of the instrument: nominal measuring range, accuracy class, scale, supply voltage, size (size), weight. If the site you see the discrepancy device name (model) specifications, photo or documents attached - let us know - you will get a useful gift with-selling device.

 

While the need to clarify the overall weight and size or the size of the individual meter you can in our service center. If you need our engineers will help you choose the most complete analog or a suitable replacement for the device you are interested. All counterparts and replacement will be tested in one of our laboratories with the full compliance to your requirements.

In the technical documentation for each device or product, information is provided on the list and amount of precious metals content. The documentation gives the exact weight in grams of precious metals: Au gold, palladium Pd, platinum Pt, silver Ag, tantalum Ta and other platinum group metals (PGM) per unit item. These precious metals are found in nature in very limited quantities and therefore have such a high price.

On our website you can familiarize yourself with the technical characteristics of devices and obtain information on the content of precious metals in devices and radio components manufactured in the USSR. We draw your attention to the fact that often the actual content of precious metals differs by 10-25% from the reference one in a smaller direction! The price of precious metals will depend on their value and mass in grams.

All text and graphic information on the site is informative. The color, shade, material, geometric dimensions, weight, content, delivery set and other parameters of the goods presented on the site may vary depending on the batch of production and year of manufacture. Check with the sales department for more information.

 

If you can make repairs to the device yourself, our engineers can provide you with a complete set of necessary technical documentation: circuit diagram TO, ER, FD, PS. We also have an extensive database of technical and metrological documents: technical specifications (TS), the terms of reference (TOR), GOST (DSTU), the industry standard (OST) test procedure, the method of certification, verification scheme for more than 3,500 types of measuring equipment from the manufacturer this equipment. From the site you can download all the necessary software (the software driver) is required for the product purchased.

We carries out repairs and maintenance of measuring equipment in more than 75 different factories of the former Soviet Union and CIS.

We also have a library of legal documents that are related to our field of activity: the law, code, ordinance, decree, temporary position.