P-326-4 P-326-4
4.9 63
Remote P-326-4 measuring and switching (P3264, P 4 326, P-3264, P 3264, P326-4, P326 4)
Together with a measuring generator P-326-1, and a universal measure of the level of P-326-2 is designed to measure communication lines, channels and circuits systems with frequency division with their setup, maintenance and repair in the frequency range 0.2 kHz-2100kGts;
The limits of attenuation inconsistency - from 8dB to 30dB.
The limits of measuring the damping of the asymmetry in the frequency range from 0.2 kHz to 1024kGts - 45dB.
The error of measuring the damping of inconsistency does not exceed:
- ± 1 dB - at frequencies of 150 kHz to;
- ± 1,5 dB - at frequencies above 150 kHz to 620kGts inclusive;
- ± 2 dB - at frequencies above 620kGts to 1500kGts inclusive.
The error of measuring the damping of the asymmetry does not exceed ± 2,6 dB.
Radiometric devices
generators (G2-, G3-, G4-, G5-, G6-, GK4-, GKCh, RG4-, Ya2R-, Ya5Kh-, Ya8Kh-, TR- and others)
P-326-4 remote image.

Price:

on request

 

Product information updated 02 October 2024.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

print

Product information updated 02 October 2024.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

print

Technical characteristics

Remote P-326-4 measuring and switching (P3264, P 4 326, P-3264, P 3264, P326-4, P326 4)
 
Remote P-326-4 measuring and switching together with the measuring generator P-326-1 and the universal measure of the level of P-326-2 is designed for the measurement of communication lines, channels and circuits systems with frequency division with their setup, maintenance and repair in the frequency range 0.2 kHz-2100kGts.
With the help of measuring and switching control is provided by measuring the following parameters:
- Working attenuation and amplification of symmetric and asymmetric with respect to "ground" two-port;
- Crosstalk;
- Return loss;
- Decay asymmetry.
It is designed for installation and operation of a truck body, can be used in factory and laboratory conditions.
 
Technical characteristics of the instrument panels P-326-4 measuring and switching:
 
The unit provides a temperature range of -10 º C to +50 ° C, under conditions of high humidity to 98% at 35 ° C and when exposed to frost and dew.
Operating frequency range of the measurement instrument panel P-326-4 measuring and switching:
a) objects to the input and output resistance of 600 ohms - from 0.2 kHz to 150 kHz;
b) objects with input and output impedances 135 ohms, 150 ohms - from 4 kHz to 620kGts;
c) objects with the input and output impedance of 75 ohms - from 60 to 2100 kHz.
Frequency range attenuation inconsistency symmetric, asymmetric objects with input, output impedances - from 0.2 kHz to 1500kGts.
The instrument panel P-326-4 measuring and switching provides a schema:
a) measurement of working and crosstalk symmetric with respect to "ground" of objects with a nominal impedance 135 ohms, 150 ohms, 600 ohms, working to strengthen symmetric with respect to "ground" objects memorial resistances 150 ohms, 600 ohms, and with the help provided in the instrument of balancing and matching transformers instrument panel P-326-4 measuring and switching allows you to measure operating attenuation, gain, crosstalk asymmetric with respect to "ground" of objects with a nominal impedance of 75 ohms, 135 ohms, 150 ohms and 600 ohms, and strengthening business-symmetric "land" objects with a nominal impedance of 135 ohms;
b) Attenuation of inconsistency symmetric with respect to "ground" of objects with a nominal impedance 135 ohms, 150 ohms, 600 ohms, unbalanced - with a nominal impedance of 75 ohms, 135 ohms, 150 ohms, 600 ohms;
c) measuring the damping of the asymmetry of the objects with a nominal impedance 135 ohms, 150 ohms and 600 ohms.
Measurement range instrument panel P-326-4-switching attenuation measurement inconsistency - from 8dB to 30dB.
The limits of measuring the damping of the asymmetry in the frequency range from 0.2 kHz to 1024kGts - 45dB.
Own crosstalk between input and output circuits of the symmetrical panel P-326-4 measuring and comparing the switching frequencies up to 620kGts and between input and output unbalanced circuits at frequencies up to compare 2100kGts - at least 120dB.
The error of measuring the damping of inconsistency does not exceed:
- ± 1 dB - at frequencies of 150 kHz to;
- ± 1,5 dB - at frequencies above 150 kHz to 620kGts inclusive;
- ± 2 dB - at frequencies above 620kGts to 1500kGts inclusive.
Measurement error of the instrument panel P-326-4 measuring and switching the damping of the asymmetry does not exceed ± 2,6 dB.
Switching device provides a method of comparing measurements.
Crosstalk between the outputs, switched the key - not less than 40 dB.
The device has Baluns and matching transformers that provide coordination and balancing:
- Symmetric and asymmetric with respect to "ground" with a nominal impedance of two-135 ohm symmetrical four-pole with a nominal impedance 150 ohms;
- Symmetric with respect to "ground" with two-port impedance 600 ohm balanced or unbalanced with respect to "ground" a four with a nominal impedance 150 ohms, 135 ohms;
- Symmetric with respect to "ground" with a nominal impedance of two-150 ohms, 600 ohms unbalanced four-pole with impedance 150 ohms, 600 ohms.
Frequency range of transformers:
- 135 ohms Om/150, 150 ohms Om/150 - from 4 kHz to 620kGts;
- 600 ohms Om/600, 600 ohms Om/135 - from 0.2 kHz to 150 kHz;
- 150 ohms Om/600 - from 10 kHz to 150 kHz.
The working decay of transformers:
- 600 ohms Om/150, 150 Om/135 ohms, 150 ohms at Om/150 50kHz - less than 0.4 dB;
- 600 ohms Om/600, 600 Om/135 ohms at 1 kHz - no more than 0.4 dB.
Uneven frequency response attenuation transformers with respect to the damping at medium frequencies is less than ± 0,4 dB.
The damping of the asymmetry of transformers in the working range of frequencies - at least 43dB.
In the instrument panel measuring and switching P-326-4 consists of two stores damping:
- Shop symmetric damping with input and output impedance 600 ohms (M3 Z = 600 ohms);
- Shop symmetric damping with input and output impedance 150 ohms to use it as an asymmetric store the input and output impedance of 75 ohms (M3 Z = 150 ohms Om/75).
The maximum permissible input level Z = 150 M3 Om/75 ohm - 10 dB at the input of M3 Z = 600 ohms - 20 dB.
The maximum attenuation of each store unit control P-326-4 measuring and switching - 109.9 dB with the possibility of changes in 0.1 dB.
The error on the decay of the working shops dc does not exceed the attenuation at a nominal:
- From 0 dB to 10 dB inclusive - ± 0,1 dB;
- More than 10 dB to 40 dB inclusive - ± 0,2 dB;
- More than 40 dB to 80 dB inclusive - ± 0,4 dB;
- More than 80 dB to 109.9 dB inclusive - ± 1 dB.
The deviation of the input and output impedances of rated stores does not exceed ± 1%.
Uneven frequency response of the instrument panel P-326-4 measuring and switching does not exceed:
- ± 0,1 dB - Shop fade input and output impedance 150 ohms in the frequency range of 4 kHz, and 620kGts Shop fade input and output impedance of 75 ohms in the frequency range 60kGts-2100kGts the attenuation is 10 dB up to;
- ± 0,3 dB - Shop fade input and output impedance 600 ohms in the frequency range 0.2 kHz to 150 kHz at 0 dB attenuation on up to 80 dB, inclusive, to fade store the input and output impedance 150 ohms in the frequency range 4kHz-620kGts for Shop fade input and output impedance of 75 ohms in the frequency range 60kGts-2100kGts during fades of 10 dB to 80 dB, inclusive.
Additional error shops damping control unit P-326-4 measuring and switching on the input and output resistances shall not exceed:
- ± 0,5% for every 10 ° C from the nominal values ​​- in conditions of high and low temperatures, frost and dew;
- ± 2% from the nominal values ​​- in conditions of high humidity.
Additional error control unit stores the P-326-4 measuring and switching the attenuation does not exceed:
- ± 0,05 dB - 10 dB attenuation up to and including;
- ± 0,1 dB - attenuation over 10dB to 40dB up to and including;
- ± 0,2 dB - 40 dB for attenuations above 80 dB up to and including;
- ± 0,5 dB - 80 dB for attenuation over
for every 10 ° C in conditions of high and low temperatures, as well as in conditions of frost and dew;
- ± 0,2 dB - 10 dB attenuation up to and including;
- ± 0,4 dB - 10 dB for attenuations above 40 dB up to and including;
- ± 0,8 dB attenuation over 40 dB to 80 dB, inclusive;
- ± 2 dB - 80 dB for attenuation over
in damp conditions.
The instrument panel P-326-4 measuring and switching element has a decay 20dB with an input and output resistance of 150 ohms ± 1,5 Ohm to 75 Ohm symmetrical and ± 0,75 ohms unbalanced with respect to "ground" schemes.
The error on the decay of the working-level dc does not exceed ± 0,15 dB.
The maximum allowable input level control unit P-326-4 measuring and switching - 20dB.
Parameters of measurement and control and switching devices in it, normalized by measuring the nest.
Overall dimensions of the device control panel P-326-4 measuring and switching does not exceed 260H500H480mm.
Unit weight does not exceed 25kg. 
Rate the product: P-326-4
Number of views: 2873
Product rating: 4.5
Number of grades: 443
* rating and all product statistics are updated once a month; information is current as of 17 October 2024

Photos: P-326-4

P-326-4 remote image.

P-326-4 remote image.

P-326-4 front view.

P-326-4 front view.

P-326-4 side view.

P-326-4 side view.

P-326-4 rear view.

P-326-4 rear view.

P-326-4 side view.

P-326-4 side view.

P-326-4 overhead view.

P-326-4 overhead view.

P-326-4 bottom view.

P-326-4 bottom view.

Leading online store Zapadpribor - a huge selection of measuring equipment for the best value and quality. So you can buy inexpensive devices, we monitor competitors' prices and are always ready to offer a lower price. We only sell quality products at the best prices. On our site you can buy cheaply as the latest innovations and proven equipment from the best manufacturers.

The site includes a special offer «buy at the best price» - if other Internet resources (bulletin board, forum or announcement of another online service) in products presented on our site, the lower price, we will sell it to you even cheaper! Buyers also additional discount for leaving a review or photo of use of our products.

In the price list contains not the whole range of products offered. Prices of goods, not included in the price list can learn to contact the manager. Also, our managers You can get detailed information about how cheap and profitable to buy instrumentation wholesale and retail. Telephone and e-mail for advice on the purchase , delivery or receipt are shown on the description of the goods. We have the most qualified staff, quality equipment and the best price.

 

Online store Zapadpribor - the official manufacturer's dealer test equipment. Our goal - selling high quality goods with best price offer and service to our customers. Our store can not only sell you the necessary instrument, but also offer additional services to its calibration, repair and installation. That you have a pleasant experience when shopping on our site, we have provided special gifts guaranteed to the most popular products.

 

We offer fast international shipping to almost every country in the world: Australia, Austria, Azerbaijan, Albania, Algeria, Anguilla, Angola, Antigua and Barbuda, Argentina, Aruba,  Bahamas, Bangladesh, Barbados, Bahrain, Belize, Belgium, Benin, Bermuda, Bulgaria, Bolivia, Bonaire, Sint-E. and Saba, Bosnia and Herzegovina, Botswana, Brazil, British Virgin Islands, Brunei Darussalam, Burkina Faso, Burundi, Bhutan, VietNam, Vanuatu, Vatican City, Venezuela, Armenia, Gabon, Guyana, Haiti, Gamia, Gambia, Ghana, Guatemala, Guinea, Gibraltar, Honduras, Hong Kong, Grenada, Greenland, Greece, Georgia, Denmark, Democratic Republic of the Congo, Jersey, Djibouti, Dominica, Dominican Republic, Ecuador, Eswatine, Estonia, Ethiopia, Egypt, Zambia, Zimbabwe, Jordan Indonesia, Ireland, Iceland, Spain, Italy, Cape Verde, Kazakhstan, Cayman Islands, Cambodia, Cameroon, Canada, Qatar, Kenya, Kyrgyzstan, China, Cyprus, Kiribati, Colombia, Comoros, Congo, Korea (Rep.), Costa Rica, Kot-d'Ivoire, Cuba, Kuwait, Curacao, Laos, Latvia, Lesotho, Lithuania, Liberia, Lebanon, Libya, Liechtenstein, Luxembourg, Myanmar, Mauritius, Mauritania, Madagascar, Macao, Malawi, Malaysia, Mali, Maldives, Malta, Morocco, Mexico, Mozambique, Moldova, Monaco, Monaco, Namibia, Nauru, Nepal, Niger, Nigeria, Netherlands, Germany, New Zealand, New Caledonia, Norway, UAE, Oman, Cook Islands, Pakistan, Palestine, Panama, Papua New Guinea, Paraguay, Peru, South Africa, Poland, Portugal, Republic of Chad, Rwanda, Romania, El Salvador, Samoa, San Marino, Saudi Arabia, Swaziland, Seychelles, Senegal, Saint Vincent and the Grenadines, Saint Kitts and Nevis, Saint Lucia, Serbia, Singapore, Sint Maarten, Slovakia, Slovenia, Solomon Islands, United Kingdom of Great Britain and Northern Ireland, Sudan, Suriname, East Timor (Timor-Leste), USA, Sierra Leone, Tajikistan, Taiwan, Thailand, Tanzania (United Republic of), Togo, Tonga, Trinidad and Tobago, Tuvalu, Tunisia, Turkey, Turkmenistan, Uganda, Hungary, Uzbekistan, Uruguay, Faroe Islands, Fiji, Philippines, Finland, France, French Polynesia, Croatia, Central African Republic, Czech Republic, Chile, Montenegro, Switzerland, Sweden, Sri Lanka, Jamaica, Japan.

We also provide such metrological procedure: calibration, tare, graduated, testing of measuring instruments.

The online store takes an active part in such procedures as electronic bidding, tender, auction.

If there is no site in the descriptive information you need on the device you can always turn to us for help. Our qualified managers will update for you on the technical characteristics of the device from its technical documentation: user manual, certificate, form, operating instructions, diagram. If necessary, we will take a photo of your device, or a device stand. You can leave feedback on the unit purchased from us, the meter, the device, indicator, or product. Your review for your approval will be published on the site without contact information.

 

Description of the instruments taken from the technical documentation or technical literature. Most pictures of products made directly by our experts prior to shipment of goods. In the description of the device provided the main technical characteristics of the instrument: nominal measuring range, accuracy class, scale, supply voltage, size (size), weight. If the site you see the discrepancy device name (model) specifications, photo or documents attached - let us know - you will get a useful gift with-selling device.

 

While the need to clarify the overall weight and size or the size of the individual meter you can in our service center. If you need our engineers will help you choose the most complete analog or a suitable replacement for the device you are interested. All counterparts and replacement will be tested in one of our laboratories with the full compliance to your requirements.

In the technical documentation for each device or product, information is provided on the list and amount of precious metals content. The documentation gives the exact weight in grams of precious metals: Au gold, palladium Pd, platinum Pt, silver Ag, tantalum Ta and other platinum group metals (PGM) per unit item. These precious metals are found in nature in very limited quantities and therefore have such a high price.

On our website you can familiarize yourself with the technical characteristics of devices and obtain information on the content of precious metals in devices and radio components manufactured in the USSR. We draw your attention to the fact that often the actual content of precious metals differs by 10-25% from the reference one in a smaller direction! The price of precious metals will depend on their value and mass in grams.

All text and graphic information on the site is informative. The color, shade, material, geometric dimensions, weight, content, delivery set and other parameters of the goods presented on the site may vary depending on the batch of production and year of manufacture. Check with the sales department for more information.

 

If you can make repairs to the device yourself, our engineers can provide you with a complete set of necessary technical documentation: circuit diagram TO, ER, FD, PS. We also have an extensive database of technical and metrological documents: technical specifications (TS), the terms of reference (TOR), GOST (DSTU), the industry standard (OST) test procedure, the method of certification, verification scheme for more than 3,500 types of measuring equipment from the manufacturer this equipment. From the site you can download all the necessary software (the software driver) is required for the product purchased.

We carries out repairs and maintenance of measuring equipment in more than 75 different factories of the former Soviet Union and CIS.

We also have a library of legal documents that are related to our field of activity: the law, code, ordinance, decree, temporary position.