N307 N307
4.9 63
The device is a two-coordinate recorder N307 (N 307, N-307, h307, h 307, h-307)
Intended for registration in rectangular coordinates in linear or logarithmic scale functional dependence of the two measured values ​​presented in the form of electrical signals of electrical voltage, sinusoidal AC voltage (rms) at frequencies from 45Hz to 20,000 Hz, as well as one of the values ​​shown in function of time.
Electrical measuring instruments
analog panel meters
N307/2 device image.
  • Typical photos 

Price:

on request

 

In stock:   more than 100 pieces of all denominations.

Product information updated 11 December 2024.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

print

Product information updated 11 December 2024.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

print

Technical characteristics

The device is a two-coordinate recorder N307 (N 307, N-307, h307, h 307, h-307)
 
The device is a two-coordinate recorder N307 is intended for registration in rectangular coordinates in linear or logarithmic scale functional dependence of the two measured values ​​presented in the form of electrical signals of electrical voltage, sinusoidal AC voltage (rms) at frequencies from 45Hz to 20,000 Hz, as well as one of these quantities as functions of time.
Depending on the set of exchangeable units unit recording device has three two-axis performance N307: N307 / 1, N307 / 2, N307 / 3.
The device N307 / 1 contains two blocks of constant tension and time base unit;
The device N307 / 2 contains two sets of DC, two blocks of alternating voltage and time base unit;
The device N307 / 3 contains two sets of DC voltage, AC power, the unit of frequency, power and resistance block timebase;
 
Technical characteristics of the devices two-coordinate automatic recording devices N307:
 
Operating conditions:
- Temperature - 10 º C to 35 º C;
- Relative humidity - 80%;
On the instrument instrument recording two-axis N307 - desktop;
Power supply - from a network of single-phase AC 220V +22 V, 220-33B, 50 Hz ± 1 Hz;
The device consists of a recorder and removable blocks of functional modules.
The nominal dimensions of the lengths of the coordinates of the field recording device recording a two-coordinate device N307:
- Coordinate X - 350mm;
- Coordinate Y - 250mm;
Scale diagram form the mesh device two-axis instrument recording N307:
- When registering on a linear scale - 1mm;
- When registering on a logarithmic scale - not less than 1 mm;
The scale and range of recording correspond to the values ​​specified in Tables 1-5;
Limits smooth adjustment of the linear scale recording device recording a two-coordinate device N307 with blocks of the DC and AC voltages (with the exception of scale 10V/sm) equal to twice the size of registration;
Ranges of calibrated offset device with a DC voltage equal to ± 100%, ± 200% of the range of registration;
The scale and range of recording correspond to the values ​​specified in Tables 6-8;
Smooth non-calibrated instrument zero offset two-coordinate recording instrument N307 installs a recording device at any point in diagrammatic form;
Limit of acceptable basic error of the instrument in the absence of bias, expressed as a percentage of normalizing the values ​​in linear scale, the following values:
- ± 0,5% - to block DC voltage;
- ± 1,5% - with the AC unit in the frequency range of 45Hz-20000Hz;
- ± 1% - with blocks of frequency and resistance.
Normalizing the value of N, expressed in units of the input signal is given by:
 
N = M (L + L Mr. cm)
 
where M - the scale of registration in accordance with tables 1-5; L nom - nominal length coordinate, cm; L cm - the absolute value of bias, see (plus L cm - Zero offset in the direction of coordinate axis, minus L cm - in the opposite direction);
Limit of acceptable basic error of the instrument recording device N307 two-axis,expressed as a percentage of normalizing the values ​​in a logarithmic scale is equal to the following values:
- ± 1,5% - to block DC voltage;
- ± 2,5% - with blocks of alternating voltage in the frequency range of 1000Hz, 20000Hz, frequency and resistance;
For normalizing value is accepted upper range of the second decade of registration;
Limit of acceptable basic error of the instrument recording device with two-axis N307 unit at a constant voltage bias, expressed as a percentage of the normalizing values ​​are equal to the following values:
- ± 0,55% - with zero offset ± 100%;
- ± 0,56% - with zero offset ± 200%;
The scale of the sweep time equal to - 0.25 V / cm, 0.5 s / cm, 1.0 s / cm, 2.5 s / cm, 5.0 s / cm; 10s/sm; 25s/sm; 50s/sm;
 
Table 1: The scale and range of the instrument recording device recording a two-coordinate N307
 
The scale of registration of mV / cm
Ranges of registration with the block of constant voltage, mV
Ranges of registration with the block of constant voltage, mV
linear scale
logarithmic scale
X coordinate
Y coordinate
X coordinate
first decade
second decade
0.025 mW / cm
0mV, 0 875mV
0mV, 0 625mV
-
-
0.05 mV / cm
0mV-1, 75mV
0mV-1, 25mV
-
-
0.1 mV / cm
0mV-3, 5mV
0mV-2, 5mV
-
-
0.25 mW / cm
0mV-8, 75mV
0mV-6, 25mV
-
-
0.5 mV / cm
0mV-17 5mV
0mV-12 5mV
0.175 mV-1, 75mV
1.75 mV-17 5mV
1mV/sm
0mV-35mV
0mV-25mV
0.35 mV-3, 5mV
3.5 mV-35mV
2.5 mV / cm
0mV-87 5mV
0mV-62 5mV
0.875 mV-8, 75mV
8.75 mV-87 5mV
5mV/sm
0mV-175mV
0mV-125mV
1.75 mV-17 5mV
17.5 mV-175mV
10mV/sm
0mV-350mV
0mV-250mV
3.5 mV-35mV
35mV 350mV-
25mV/sm
0mV-875mV
0mV-625mV
8.75 mV-87 5mV
87.5 mV-875mV
 
The scale of registration of mV / cm
Ranges of registration with the block of constant voltage, mV
Ranges of registration with the block of constant voltage, mV
linear scale
logarithmic scale
X coordinate
Y coordinate
Y coordinate
first decade
second decade
0.025 mW / cm
0mV, 0 875mV
0mV, 0 625mV
-
-
0.05 mV / cm
0mV-1, 75mV
0mV-1, 25mV
-
-
0.1 mV / cm
0mV-3, 5mV
0mV-2, 5mV
-
-
0.25 mW / cm
0mV-8, 75mV
0mV-6, 25mV
-
-
0.5 mV / cm
0mV-17 5mV
0mV-12 5mV
0.125 mV-1, 25mV
1.25 mV-12 5mV
1mV/sm
0mV-35mV
0mV-25mV
0.25 mV 2, 5mV
2.5 mV-25mV
2.5 mV / cm
0mV-87 5mV
0mV-62 5mV
0.625 mV-6, 25mV
6.25 mV-62 5mV
5mV/sm
0mV-175mV
0mV-125mV
1.25 mV-12 5mV
12.5 mV-125mV
10mV/sm
0mV-350mV
0mV-250mV
2.5 mV-25mV
25mV 250mV-
25mV/sm
0mV-875mV
0mV-625mV
6.25 mV-62 5mV
62.5 mV-625mV
 
Note:
- A range of recording device recording a two-coordinate device N307 for each coordinate equal to the product size to a nominal length of the coordinates;
- When registering on a logarithmic scale with the normalized error of the measured voltage should be less than 0.5 mV.
 
Table 2 The scale and range of the instrument recording device recording a two-coordinate N307
 
The scale of the registration / cm
Ranges of registration with the block of constant voltage, V
Ranges of registration with the block of constant voltage, V
linear scale
logarithmic scale
X coordinate
Y coordinate
X coordinate
first decade
second decade
0.05 / cm
0V-1, 75B
0V-1, 25B
0.0175 V-0, 175V
.175 B-1, 75B
0.1 V / cm
0V-3, 5B
0V-2, 5V
0.035-0, 35V
0.35-3, 5B
0.25 V / cm
0V-8, 75B
0V-6, 25B
0.0875 V-0, 875V
0.875-8, 75B
0.5 V / cm
0V-17, 5V
0V-12, 5V
.175 B-1, 75B
1.75-17, 5V
1V/sm
0V-35V
0V-25V
0.35-3, 5B
3.5V-35V
2.5 V / cm
0V-87, 5V
0V-62, 5V
0.875-8, 75B
8.75 B-87, 5V
5V/sm
0V-175V
0V-125V
1.75-17, 5V
17.5-175V
10V/sm
0V-350V
0V-250V
3.5V-35V
35V-350V
 
The scale of the registration / cm
Ranges of registration with the block of constant voltage, V
Ranges of registration with the block of constant voltage, V
linear scale
logarithmic scale
X coordinate
Y coordinate
Y coordinate
first decade
second decade
0.05 / cm
0V-1, 75B
0V-1, 25B
0.0125 V-0, 125V
.125 B-1, 25B
0.1 V / cm
0V-3, 5B
0V-2, 5V
0.025-0, 25V
0.25-2, 5V
0.25 V / cm
0V-8, 75B
0V-6, 25B
0.0625 V-0, 625V
0.625 V-6 25V
0.5 V / cm
0V-17, 5V
0V-12, 5V
.125 B-1, 25B
1.25-12, 5V
1V/sm
0V-35V
0V-25V
0.25-2, 5V
2.5-25V
2.5 V / cm
0V-87, 5V
0V-62, 5V
0.625 V-6 25V
6.25 B-62, 5V
5V/sm
0V-175V
0V-125V
1.25-12, 5V
12,5-125V
10V/sm
0V-350V
0V-250V
2.5-25V
25V-250V
 
   
Table 3 The scale and range of the instrument recording device recording a two-coordinate N307
 
Scale registration / cm
Ranges of registration with the block of alternating voltage, V
Ranges of registration with the block of alternating voltage, V
linear scale
logarithmic scale
X coordinate
Y coordinate
X coordinate
first decade
second decade
0.01 V / cm
0V-0, 35V
0V-0, 25V
0.0035 V-0, 035V
0.035-0, 35V
0.025 / cm
0V-0, 875V
0V-0, 625V
0.00875-0, 0875V
0.0875 V-0, 875V
0.05 / cm
0V-1, 75B
0V-1, 25B
0.0175 V-0, 175V
.175 B-1, 75B
0.1 V / cm
0V-3, 5B
0V-2, 5V
0.035-0, 35V
0.35-3, 5B
0.25 V / cm
0V-8, 75B
0V-6, 25B
0.0875 V-0, 875V
0.875-8, 75B
0.5 V / cm
0V-17, 5V
0V-12, 5V
.175 B-1, 75B
1.75-17, 5V
1V/sm
0V-35V
0V-25V
0.35-3, 5B
3.5V-35V
2.5 V / cm
0V-87, 5V
0V-62, 5V
0.875-8, 75B
8.75 B-87, 5V
5V/sm
0V-175V
0V-125V
1.75-17, 5V
17.5-175V
10V/sm
0V-350V
0V-250V
3.5V-35V
35V-350V
 
Scale registration / cm
Ranges of registration with the block of alternating voltage, V
Ranges of registration with the block of alternating voltage, V
linear scale
logarithmic scale
X coordinate
Y coordinate
Y coordinate
first decade
second decade
0.01 V / cm
0V-0, 35V
0V-0, 25V
0.0025 V-0, 025V
0.025-0, 25V
0.025 / cm
0V-0, 875V
0V-0, 625V
0.00625 V-0, 0625V
0.0625 V-0, 625V
0.05 / cm
0V-1, 75B
0V-1, 25B
0.0125 V-0, 125V
.125 B-1, 25B
0.1 V / cm
0V-3, 5B
0V-2, 5V
0.025-0, 25V
0.25-2, 5V
0.25 V / cm
0V-8, 75B
0V-6, 25B
0.0625 V-0, 625V
0.625 V-6 25V
0.5 V / cm
0V-17, 5V
0V-12, 5V
.125 B-1, 25B
1.25-12, 5V
1V/sm
0V-35V
0V-25V
0.25-2, 5V
2.5-25V
2.5 V / cm
0V-87, 5V
0V-62, 5V
0.625 V-6 25V
6.35 B-62, 5V
5V/sm
0V-175V
0V-125V
1.25-12, 5V
12,5-125V
10V/sm
0V-350V
0V-250V
2.5-25V
25V-250V
 
  Note: When registering a logarithmic scale, the scope for error is set in the second line number of the first decade.
 
Table 4: The scale and range of the instrument recording device recording a two-coordinate N307
 
The scale of registration, Hz / cm
Ranges of registration with the unit of frequency, Hz
Ranges of registration with the unit of frequency, Hz
 
linear scale
logarithmic scale
 
X coordinate
Y coordinate
X coordinate
 
 
 
first decade
second decade
5Gts/sm
20Hz-175Gts
20Hz-125Gts
-
-
10Gts/sm
20Hz-350Gts
20Hz-250Hz
-
35Hz- 350Gts
25Gts/sm
20Hz-875Gts
20Hz-625Gts
-
87.5 Hz 875Gts
50Gts/sm
20Hz-1750Gts
20Hz-1250Gts
-
175Gts-1750Gts
100Gts/sm
20Hz-3500Gts
20Hz-2500Gts
35Hz-350Gts
350Gts-3500Gts
250Gts/sm
20Hz-8750Gts
20Hz-6250Gts
87.5 Hz 875Gts
875Gts-8750Gts
500Gts/sm
20Hz-17500Gts
20Hz-12500Gts
-
1750Gts-17500Gts
1000Gts/sm
20Hz-35000Gts
20Hz-25000Hz
350Gts-3500Gts
3500Gts-35000Gts
2500Gts/sm
20Hz-87500Gts
20Hz-62500Gts
875Gts-8750Gts
8750Gts-87500Gts
5000Gts/sm
20Hz-175000Gts
20Hz-125000Gts
-
17500Gts-175000Gts
10000Gts/sm
20Hz-350000Gts
20Hz-250000Gts
3500Gts-35000Gts
35000Gts-350000Gts
25000Gts/sm
20Hz-875000Gts
20Hz-625000Gts
8750Gts-87500Gts
87500Gts-875000Gts
 
The scale of registration, Hz / cm
Ranges of registration with the unit of frequency, Hz
Ranges of registration with the unit of frequency, Hz
 
linear scale
logarithmic scale
 
X coordinate
Y coordinate
Y coordinate
 
 
 
first decade
second decade
5Gts/sm
20Hz-175Gts
20Hz-125Gts
-
-
10Gts/sm
20Hz-350Gts
20Hz-250Hz
-
25Hz- 250Hz
25Gts/sm
20Hz-875Gts
20Hz-625Gts
-
62.5 Hz 625Gts
50Gts/sm
20Hz-1750Gts
20Hz-1250Gts
-
125Gts-1250Gts
100Gts/sm
20Hz-3500Gts
20Hz-2500Gts
25Hz-250Hz
250Hz-2500Gts
250Gts/sm
20Hz-8750Gts
20Hz-6250Gts
62.5 Hz 625Gts
625Gts-6250Gts
500Gts/sm
20Hz-17500Gts
20Hz-12500Gts
-
1250Gts-1250Gts
1000Gts/sm
20Hz-35000Gts
20Hz-25000Hz
250Hz-2500Gts
2500Gts-25000Hz
2500Gts/sm
20Hz-87500Gts
20Hz-62500Gts
625Gts-6250Gts
6250Gts-62500Gts
5000Gts/sm
20Hz-175000Gts
20Hz-125000Gts
-
12500Gts-125000Gts
10000Gts/sm
20Hz-350000Gts
20Hz-250000Gts
2500Gts-25000Hz
25000Hz-250000Gts
25000Gts/sm
20Hz-875000Gts
20Hz-625000Gts
6250Gts-62500Gts
62500Gts-625000Gts
  
Note: When registering a logarithmic scale, the scope of error is set in the second line number of the first decade.
 
 
Table 5: The scale and range of the instrument recording device recording a two-coordinate N307
 
The scale of regist-ration, ohm / cm
Bands with registered unit AC, Ohm
linear scale
logarithmic scale
X coordinate
Y coor-
dinate
X coordinate
Y coordinate
first decade
second decade
first decade
second decade
1 W / cm
0 ohm-35 ohm
0 ohm-25 ohm
-
-
-
-
5 ohms / cm
0 ohm-175 ohm
0 ohm-125 ohm
-
-
-
-
10 ohms / cm
0 ohm-350 ohm
0 ohm-250 ohm
3.5 Ohm, 35 Ohm
35 Ohm-350 Ohm
2.5 Ohm, 25 Ohm
25 ohms, 250 ohms
50 ohms / cm
0 ohm-1750 ohms
0 ohm-1250 ohms
17.5 Ohm-175 Ohm
175 Ohm 1750 Ohm
12.5-W-125 Ohm
125 ohm 1250 ohms
1 kW / cm
0 ohms-35 ohms
0 ohms-25 ohms
0.35 ohm-3, 5 kOhm
3.5 ohms-35 ohms
0.25 ohm-2, 5 kOhm
2.5 ohms-25 ohms
5 kOhm / cm
0 ohm-175 ohm
0 ohm-125 ohm
1.75 ohm-17, 5 kOhm
17.5 ohm-175 ohm
1.25 ohm-12, 5 kOhm
12.5 ohm-125 ohm
10 k / cm
0 ohm-350 ohm
0 ohm-250 ohm
3.5 ohms-35 ohms
35 ohm-350 ohm
2.5 ohms-25 ohms
25 ohm-250 ohm
50 k / cm
0 ohm-1750 ohms
0 ohm-1250 ohms
17.5 ohm-175 ohm
175 ohms-1750 ohms
12.5 ohm-125 ohm
125 ohms- 1250 ohms
 
Note: When registering a logarithmic scale, the scope of error is set in the second line number of the first decade.
 
Table 6 The scale and range of the instrument recording device recording a two-coordinate N307
 
The scale of registration, mV / cm
The range of registration to the coordinate X
100% offset, mV
-200% offset, mV
100% offset, mV
200% offset, mV
0.025 mW / cm
0.875 mV-1, 75mV
1.75 mV-2 65mV
-0.875 MV 0mV
-1.75 MV - 0, 875mV
0.05 mV / cm
1.75 mV-3, 5mV
3.5 mV-5, 25mV
-1.75 MV 0mV
-3.5 MV - 1 75mV
0.1 mV / cm
3.5 mV-7mV
7mV-10 5mV
-3.5 MV 0mV
-7mV - 3, 5mV
0.25 mW / cm
8.75 mV-17 5mV
17.5 mV-26, 25mV
-8.75 MV 0mV
-17.5 MV - 8, 75mV
0.5 mV / cm
17.5 mV-35mV
35mV-52 5mV
-17.5 MV 0mV
-35mV - 17, 5mV
1mV/sm
35mV 70mV-
70mV 105mV-
-35mV, 0mV
-70mV - 35mV
2.5 mV / cm
87.5 mV-175mV
175mV-265mV
-87.5 MV 0mV
-175mV - 87, 5mV
5mV/sm
175mV-350mV
350mV-525mV
-175mV, 0mV
-350mV - 175mV
10mV/sm
350mV-700mV
700mV-1050mV
-350mV, 0mV
-700mV - 350mV
25mV/sm
8750mV 1750mV-
1750mV 2650mV-
-875mV, 0mV
-1750mV - 875mV
 
Table 7: The scale and range of the instrument recording device recording a two-coordinate N307
 
The scale of registration, mV / cm
The range of registration to the coordinate Y
100% offset, mV
-200% offset, mV
100% offset, mV
200% offset, mV
0.025 mW / cm
0.625 mV-1, 25mV
1.25 mV-1 875mV
-0.675 MV 0mV
-1.25 MV - 0, 625mV
0.05 mV / cm
1.25 mV 2, 5mV
2.5 mV-3, 75mV
-1.25 MV 0mV
-2.5 MV - 1 25mV
0.1 mV / cm
2.5 mV-5mV
5mV-7, 5mV
-2.5 MV 0mV
-5mV - 2, 5mV
0.25 mW / cm
6.25 mV-12 5mV
12.5 mV-18, 75mV
-6.25 MV 0mV
-2.5 MV - 6, 25mV
0.5 mV / cm
12.5 mV-25mV
25mV-37 5mV
-12.5 MV 0mV
-25mV - 12, 5mV
1mV/sm
25mV 50mV-
50mV 75mV-
-25mV, 0mV
-50mV - 25mV
2.5 mV / cm
62.5 mV-125mV
125mV-187, 5mV
-62.5 MV 0mV
-125mV - 62, 5mV
5mV/sm
125mV-250mV
250mV-375mV
-125mV, 0mV
-250mV - 125mV
10mV/sm
250mV-500mV
500mV-750mV
-250mV, 0mV
-500mV - 250mV
25mV/sm
625mV-1250mV
1250mV 1875mV-
-625mV, 0mV
-1250mV - 6250mV
 
Table 8: The scale and range of the instrument recording device recording a two-coordinate N307
 
Scale registration / cm
The range of registration to the coordinate X, Y
100% offset, in
offset -200%, B
offset 100% in
offset 200% in
X coordinate
0.05 / cm
1.75-3, 5B
3.5 V-5, 25B
-1.75 V-0V
-3.5 V - 1, 75B
0.1 V / cm
3.5V-7V
7B-10, 5V
-3.5 V-0V
-7B - 3, 5B
0.5 V / cm
17.5-35V
35B-52, 5V
-17.5 V-0V
-35V - 17, 5V
1V/sm
35V-70V
70V-105V
-35V-0V
-70V - 35V
2.5 V / cm
In 87.5-175V
175V-262, 5V
-87.5 V-0V
-175V - 87, 5V
5V/sm
175V-350V
350V-525V
-175V-0V
-350V - 175V
10V/sm
350V-700V
700V-1050V
-350V-0V
-700V - 350V
 
Y coordinate
0.05 / cm
1.25-2, 5V
2.5-3, 75B
-1.25 V-0V
-2.5 V - 1, 25B
0.1 V / cm
2.5-5V
5B-7, 5mV
-2.5 V-0V
5 V - 2, 5V
0.25 V / cm
6.25 B-12, 5V
12.5 V-18, 75V
-6.25 V-0V
-2.5 V - 6, 25B
0.05 / cm
12,5-25V
25B-37, 5V
-12.5 V-0V
-25V - 12, 5V
1V/sm
25V-50V
50V-75V
-25V-0V
-50V - 25V
2.5 V / cm
In 62.5-125V
125V-187, 5V
-62.5 V-0V
-125V - 62, 5V
5V/sm
125V-250V
250V-375V
-125V-0V
-250V - 125V
10V/sm
250V-500V
500V-750V
-0V-250V
-500V - 250V
 
Time base range, equal to the product of the scale of the nominal length of the X, correspond to the following values: 0s, 8, 75S; 0s-17s, 5s, 0s-35s, 0s-87s, 5s, 0s-17s, 5s, 0s-350s, 0s -875s, 0s, 17505s;
Limit of acceptable error in the instrument sweep time recording device N307 two-axis, expressed as a percentage of the normalizing values ​​are equal to the following values:
- ± 1% - on the scale and sweep time 25s/sm 50s/sm;
- ± 0,5% - on the other scales;
Input resistance device with a DC voltage, AC voltage and frequency - at least 1 Mohm;
The current through the measured resistance does not exceed the values ​​shown in Table 9;
 
Table 9: The current through the device measured impedance instrument recording two-axis N307
 
The scale of the registration
1 W / cm
5 ohms / cm
10 ohms / cm
50 ohms / cm
1 kW / cm
5 kOhm / cm
10 k / cm
50 k / cm
The current through the measured resistance, mA
2.5 mA
0.5 mA
0.25 mA
0.05 mA
0.15 mA
0.03 mA
0.015 mA
0.003 mA
 
The amplitude of the input voltage during the registration rate - from 2V up to 100V;
Speed ​​recording device recording a two-coordinate device N307 - not less than 75 cm / s;
The greatest value of emission recording device after a sudden change of input signal - no more than 5% of the steady-state value;
The range of amplitudes and frequencies of sinusoidal signal recording device unit two-axis N307 submitted simultaneously to the inputs X and Y coordinates within which the divergence of the normal registration lines increasing and decreasing values ​​of the input signal is less than 1 mm are shown in Table 10;
 
Table 10 Range of amplitude and frequency sinusoidal signal recording device unit two-axis N307
 
Frequency, Hz
0.1 Hz
0.5 Hz
1Hz
2Hz
Double amplitude, mm
200mm
100mm
50mm
20mm
 
Maximum permissible error of the change attributable to changes in voltage in the range 220V ± 22V, ± 220V 33B, shall not exceed:
- ± 0,25% - with blocks of constant voltage and time base;
- ± 0,5% - with blocks of alternating voltage, frequency and resistance;
- ± 1% - if registration in the logarithmic scale;
Additional error of the instrument recording device N307 two-coordinate is expressed as the basic error;
The device is heat-holodoustoychiv during his stay in business climate conditions of use;
Maximum permissible error of the change attributable to changes in ambient temperature from the value before the temperature of the working conditions at every 10 ° C change in temperature does not exceed:
- ± 0,2% - with blocks of constant voltage;
- ± 0,5% - with blocks of frequencies, the resistance of the first time base;
- ± 1% - with power alternating voltage;
- ± 1% - if registration in the logarithmic mode;
Maximum permissible error of change in the instrument recording device N307 two-axis caused by exposure to a constant uniform magnetic field induction 0.5 mT does not exceed ± 0,25%;
The insulation resistance at normal conditions, at least:
- 40 MW - between the case and AC power circuit;
- 100 MW - between the body and the measuring circuit.
The insulation resistance at 35 ° C and relative humidity from 30% to 80% less than:
- 10 MW - between the case and AC power circuit;
- 25 MW - between the body and the measuring circuits;
Isolation unit recording device and two-axis N307 blocks stand for 1 minute effect of test voltage:
- DC 0.5 kV - between body and instrument input jacks block rate, block DC and AC voltages;
- DC 1.1 kV - between the buildings blocks of the DC and AC voltages and input jacks;
- AC 1.5 kV 50 Hz ± 1 Hz between the housing unit and AC power circuit;
Note: Instead of testing voltage alternating current is allowed to use a DC voltage equal to the value of the amplitude of the AC test voltage;
The device is a two-coordinate recording instrument provides N307 in normal operating conditions and application of the required characteristics at the end of time required to establish the operating mode;
Operation mode setup time 30 minutes;
Continuous operation of the device - 8 hours (excluding the time required to establish the operating mode);
A break to re-enable - at least 30 minutes;
Offset instrument recording device for two-axis N307 8 hours of continuous operation with a constant voltage unit - no more than 20mV;
Registration is carried out by a continuous line in ink or marker. When the velocity of the recording device 10 cm / s or more line breaks are allowed registration will not result in the loss of information;
The line width of the registration does not exceed:
- 0.6 mm - when registering with ink;
- 1mm - when registering a felt pen;
The instrument recording device provided with two-axis N307 rise recorder during recording and remote control lifting recording device;
The average time raising and lowering the pen is less than 40ms;
Maximum operating frequency pen 8Gts;
The number of cycles of depression, lowering - not less than 100,000;
The current through the switching device contacts the unit two-axis instrument recording N307 - less than 70mA;
The power consumed by the electromagnet when lowering the recording device does not exceed 5 W;
The unit provides remote control of start-up time base;
The current through the switching device contacts the instrument recording device does not exceed two-axis N307 70mA;
The power consumed by the relay when you start the time sweep not exceeding 6.5 W;
Power supply - from a network of single-phase AC 220V +22 V, 220-33B, 50 Hz ± 1 Hz, the voltage curve distortion factor less than 5%;
Upon request, a device manufactured for export to the network with a frequency of 60 Hz ± 1,2 Hz;
The power consumed by the device unit recording from two-axis N307 network at a nominal voltage not exceeding 35V ∙ A;
Overall dimensions shall not exceed 455x515x145mm;
Weight of the device unit recording two-axis N307 does not exceed 15kg;
Weight replacement unit does not exceed 0.5 kg.
Rate the product: N307
Number of views: 2143
Product rating: 4.6
Number of grades: 520
* rating and all product statistics are updated once a month; information is current as of 21 December 2024

Leading online store Zapadpribor - a huge selection of measuring equipment for the best value and quality. So you can buy inexpensive devices, we monitor competitors' prices and are always ready to offer a lower price. We only sell quality products at the best prices. On our site you can buy cheaply as the latest innovations and proven equipment from the best manufacturers.

The site includes a special offer «buy at the best price» - if other Internet resources (bulletin board, forum or announcement of another online service) in products presented on our site, the lower price, we will sell it to you even cheaper! Buyers also additional discount for leaving a review or photo of use of our products.

In the price list contains not the whole range of products offered. Prices of goods, not included in the price list can learn to contact the manager. Also, our managers You can get detailed information about how cheap and profitable to buy instrumentation wholesale and retail. Telephone and e-mail for advice on the purchase , delivery or receipt are shown on the description of the goods. We have the most qualified staff, quality equipment and the best price.

 

Online store Zapadpribor - the official manufacturer's dealer test equipment. Our goal - selling high quality goods with best price offer and service to our customers. Our store can not only sell you the necessary instrument, but also offer additional services to its calibration, repair and installation. That you have a pleasant experience when shopping on our site, we have provided special gifts guaranteed to the most popular products.

 

We offer fast international shipping to almost every country in the world: Australia, Austria, Azerbaijan, Albania, Algeria, Anguilla, Angola, Antigua and Barbuda, Argentina, Aruba,  Bahamas, Bangladesh, Barbados, Bahrain, Belize, Belgium, Benin, Bermuda, Bulgaria, Bolivia, Bonaire, Sint-E. and Saba, Bosnia and Herzegovina, Botswana, Brazil, British Virgin Islands, Brunei Darussalam, Burkina Faso, Burundi, Bhutan, VietNam, Vanuatu, Vatican City, Venezuela, Armenia, Gabon, Guyana, Haiti, Gamia, Gambia, Ghana, Guatemala, Guinea, Gibraltar, Honduras, Hong Kong, Grenada, Greenland, Greece, Georgia, Denmark, Democratic Republic of the Congo, Jersey, Djibouti, Dominica, Dominican Republic, Ecuador, Eswatine, Estonia, Ethiopia, Egypt, Zambia, Zimbabwe, Jordan Indonesia, Ireland, Iceland, Spain, Italy, Cape Verde, Kazakhstan, Cayman Islands, Cambodia, Cameroon, Canada, Qatar, Kenya, Kyrgyzstan, China, Cyprus, Kiribati, Colombia, Comoros, Congo, Korea (Rep.), Costa Rica, Kot-d'Ivoire, Cuba, Kuwait, Curacao, Laos, Latvia, Lesotho, Lithuania, Liberia, Lebanon, Libya, Liechtenstein, Luxembourg, Myanmar, Mauritius, Mauritania, Madagascar, Macao, Malawi, Malaysia, Mali, Maldives, Malta, Morocco, Mexico, Mozambique, Moldova, Monaco, Monaco, Namibia, Nauru, Nepal, Niger, Nigeria, Netherlands, Germany, New Zealand, New Caledonia, Norway, UAE, Oman, Cook Islands, Pakistan, Palestine, Panama, Papua New Guinea, Paraguay, Peru, South Africa, Poland, Portugal, Republic of Chad, Rwanda, Romania, El Salvador, Samoa, San Marino, Saudi Arabia, Swaziland, Seychelles, Senegal, Saint Vincent and the Grenadines, Saint Kitts and Nevis, Saint Lucia, Serbia, Singapore, Sint Maarten, Slovakia, Slovenia, Solomon Islands, United Kingdom of Great Britain and Northern Ireland, Sudan, Suriname, East Timor (Timor-Leste), USA, Sierra Leone, Tajikistan, Taiwan, Thailand, Tanzania (United Republic of), Togo, Tonga, Trinidad and Tobago, Tuvalu, Tunisia, Turkey, Turkmenistan, Uganda, Hungary, Uzbekistan, Uruguay, Faroe Islands, Fiji, Philippines, Finland, France, French Polynesia, Croatia, Central African Republic, Czech Republic, Chile, Montenegro, Switzerland, Sweden, Sri Lanka, Jamaica, Japan.

We also provide such metrological procedure: calibration, tare, graduated, testing of measuring instruments.

The online store takes an active part in such procedures as electronic bidding, tender, auction.

If there is no site in the descriptive information you need on the device you can always turn to us for help. Our qualified managers will update for you on the technical characteristics of the device from its technical documentation: user manual, certificate, form, operating instructions, diagram. If necessary, we will take a photo of your device, or a device stand. You can leave feedback on the unit purchased from us, the meter, the device, indicator, or product. Your review for your approval will be published on the site without contact information.

 

Description of the instruments taken from the technical documentation or technical literature. Most pictures of products made directly by our experts prior to shipment of goods. In the description of the device provided the main technical characteristics of the instrument: nominal measuring range, accuracy class, scale, supply voltage, size (size), weight. If the site you see the discrepancy device name (model) specifications, photo or documents attached - let us know - you will get a useful gift with-selling device.

 

While the need to clarify the overall weight and size or the size of the individual meter you can in our service center. If you need our engineers will help you choose the most complete analog or a suitable replacement for the device you are interested. All counterparts and replacement will be tested in one of our laboratories with the full compliance to your requirements.

In the technical documentation for each device or product, information is provided on the list and amount of precious metals content. The documentation gives the exact weight in grams of precious metals: Au gold, palladium Pd, platinum Pt, silver Ag, tantalum Ta and other platinum group metals (PGM) per unit item. These precious metals are found in nature in very limited quantities and therefore have such a high price.

On our website you can familiarize yourself with the technical characteristics of devices and obtain information on the content of precious metals in devices and radio components manufactured in the USSR. We draw your attention to the fact that often the actual content of precious metals differs by 10-25% from the reference one in a smaller direction! The price of precious metals will depend on their value and mass in grams.

All text and graphic information on the site is informative. The color, shade, material, geometric dimensions, weight, content, delivery set and other parameters of the goods presented on the site may vary depending on the batch of production and year of manufacture. Check with the sales department for more information.

 

If you can make repairs to the device yourself, our engineers can provide you with a complete set of necessary technical documentation: circuit diagram TO, ER, FD, PS. We also have an extensive database of technical and metrological documents: technical specifications (TS), the terms of reference (TOR), GOST (DSTU), the industry standard (OST) test procedure, the method of certification, verification scheme for more than 3,500 types of measuring equipment from the manufacturer this equipment. From the site you can download all the necessary software (the software driver) is required for the product purchased.

We carries out repairs and maintenance of measuring equipment in more than 75 different factories of the former Soviet Union and CIS.

We also have a library of legal documents that are related to our field of activity: the law, code, ordinance, decree, temporary position.