M42304 M42304
4.9 63
M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter (M 42304, M-42304)
Designed for current and voltage in electrical circuits, DC.
Dimensions - 80h80mm, cut-out shield 77.5 mm.
Accuracy class - 1.5, 2.5.
Tryaskoprochny and vibration.
Electrical measuring instruments
analog panel meters
ammeters and voltmeters
DC
M42304 front view (scale).

Price:

on request

 

In stock:   more than 100 pieces of all denominations.

Product information updated 04 December 2024.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

print

Product information updated 04 December 2024.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

print

Technical characteristics

M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter (M 42304, M-42304)
 
M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter designed to measure current and voltage in electrical circuits, DC.
For measurements of currents and voltages in excess of these limits are applied and additional external shunt resistor (ordered separately).
The rate of mean time to failure of devices microammeter M42304 - 55,000 hours, devices M42304 - 92,250 hours;
The average lifespan of devices for 12 years;
The design of the housing units M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter provides protection for the front panel IP50 or IP54, for the live parts - IP00.
M42304 devices ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter withstand prolonged overload current or a voltage equal to 120% of the upper limit of range for 2 hours;
The device is filled with high-quality plastic housing that can be used in harsh environments.
Calibrated wire connecting devices with shunts, supplied equipment (at customer's request). On request is possible to manufacture devices with increased protection.
Gauges Ammeter M42304, M42304 voltmeter, microammeter M42304, M42304 milliammeter, M42304 DC millivoltmeter can be made with the zero mark at the beginning or middle of the scale;
Scale devices can be implemented in any physical units, with special markings, inscriptions and so on according to the customer.
The normal position of ammeter instrumentation M42304, M42304 voltmeter, microammeter M42304, M42304 milliammeter, millivoltmeter M42304 vertical or horizontal.Possible to manufacture devices with other outside measurements on request.
 
Technical characteristics of the devices M42304 ammeters, voltmeters, M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter:
 
Dimensions - 80h80mm, cutout in the panel d - 77,5 mm;
Weight - 0.2 kg;
Other dimensions of the devices M42304 ammeters, voltmeters, M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter are shown in Figure 1;
 
Fig. 1.
М42300
where A - 80mm, B - 50mm, C - 15mm, D - 70mm, D1 - 77,5 mm, d - 3,4 mm, E - 68mm;
 
Accuracy class - 1.5, 2.5;
Measuring range
- 50mkA; 100mkA; 150mkA; 200mkA; 300mkA; 500mkA; 1000mkA (how to enable devices - directly);
- 25 mV, 50mV, 75mV, 150mV, 300mV, 500mV, 750mV, 1000mV (how to enable devices - with calibrated wire resistance 0.035 ohms ± 0,002 ohms);
The range of measurements, the voltage or current full deflection and method of use, M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter listed in Table 1;
 
Table 1: Range of measurements, the voltage or current full deflection and method of use, M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter
 
Measuring range
The resistance of the external circuit, k, at least
The voltage drop or current full deflection, no more
Way to incorporate
scale with the zero mark on the edge of the range
scale with the zero mark within the range
 
 
 
-
-
0mkA-50mkA
0mkA-100mkA
0mkA-150mkA
0mkA-200mkA
0mkA-300mkA
0mkA-500mkA
0mkA-1000mkA
25mkA-0mkA-25mkA
30mkA-0mkA-30mkA
50mkA-0mkA-50mkA
100mkA-0mkA-100mkA
150mkA-0-150mkA
200mkA-0mkA-200mkA
300mkA-0mkA-300mkA
500mkA-0mkA-500mkA
1000mkA-0mkA-1000mkA
2.5 kOhm
2.5 kOhm
2.5 kOhm
1.0 kOhm
1.0 kOhm
-
-
-
200mV
Direct
0mV-25mV
0mV-50mV
0mV-75mV
0mV-150mV
0mV-300mV
0mV-500mV
0mV-750mV
0mV-1000mV
25mV-25mV 0mV-
50mV-50mV 0mV-
75mV-75mV 0mV-
150mV, 150mV, 0mV
300mV, 300mV, 0mV
500mV, 500mV, 0mV
750mV, 750mV, 0mV
1000mV, 0mV-1000mV
-
2mA
With the calibrated wire resistance R = 0,035 ohms
± 0,002 ohms
 
Limit of acceptable basic reduced error M42304 devices ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter is:
- ± 1,5% - for instruments of accuracy class 1.5;
- ± 2,5% - for instruments of accuracy class 2.5;
without taking into account the errors of individual external shunts and additional resistances;
Normalizing values ​​are given in determining the errors are assumed equal to:
- The upper limit of range - for devices M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter with a zero mark on the edge of the measuring range;
- The sum of the modules of the upper limits of range - for units with ground level within the range of measurements;
Limit of acceptable variations in the readings M42304 ammeters, voltmeters, M42304, M42304 micro-ammeter, milliammeter M42304, M42304 is polutorakratnomu millivolt value of the limit of acceptable basic reduced error;
Deviation from index zero of the scale after the filing of the instrument during the 30s of the measured value corresponding to the upper limit of range does not exceed the values:
- For the 1.5 accuracy class - 0.9 mm;
- Accuracy class for 2.5 - 1.5 mm;
Change the current meter readings, M42304, M42304 voltmeter, microammeter M42304, M42304 milliammeter, millivoltmeter M42304 caused a change of equipment from its normal position in any direction at 45 ° (except microammeter) does not exceed the limits of acceptable la basic error.Changing the evidence must be expressed in the form of spheres of social uncertainty is given;
Changing indications caused by the influence of external homogeneous constant magnetic field with induction 0.5 mT at the most unfavorable direction of the magnetic field does not exceed ± 1,5%;
The deviation of the index of the position of rest after a sudden application of excitation, which causes changes in the final readings for 2/3 the length scale is less than ± 1,5% at the end of the scale length of 4c;
Transfer devices ammeter pointer M42304, M42304 voltmeter, microammeter M42304, M42304 milliammeter, millivoltmeter M42304 does not exceed 20% of the length scale;
The insulation between the housing and insulated from the housing electric circuits stand for 1 minute action of the test voltage AC 50 Hz ± 1 Hz, the mean value of which corresponds to:
- Under normal conditions of use - 2.0 kV;
- At high humidity in the working conditions of - 1.2 kV;
The insulation resistance between the body and isolated dc electric circuit devices M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter not less than:
a) 20 MW - at an ambient temperature of +20 º C ± 5 ° C and relative humidity from 30% to 80% at an operating voltage up to 1kV, plus 20 MW for each subsequent complete and incomplete 1000V working voltage;
b) 5 MW - at an ambient temperature of +60 ° C and a relative humidity of 80% at an operating voltage up to 1kV, plus 0.5 MW for each complete or incomplete operating voltage of 1000 V;
a) 2 MW - at ambient temperature +20 º C ± 5 ° C and a relative humidity of 95% at an operating voltage up to 1kV, plus 0.5 MW for each complete or incomplete 1000V working voltage;
Change readings ammeter M42304, voltmeter M42304, microammeter M42304, milliammeter M42304, millivoltmeter M42304 caused a deviation of ambient temperature from the normal 20 º C ± 5 ° C to any temperature between -50 º C to +60 ° C for every 10 ° C change temperature does not exceed 0.5 limit of acceptable basic error;
Changing indications caused by deviation of the relative humidity of the normal 30% -80% at 20 º C ± 5 ° C to 95% at +35 ° C does not exceed the limit of acceptable basic error;
The impact of moisture on the instruments M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter:
- Relative humidity - 98%;
- Temperature - +40 º C;
- For the duration of moisture resistance - 2 days;
- For the duration of wet strength - 8 days;
Devices retain their characteristics after exposure to vibration with acceleration and at frequencies specified in Table 4.
 
Table 4: Impact on the M42304 devices ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter with acceleration and vibration at frequencies
 
Type of device
Acceleration, m / s 2
Frequency, Hz
Dwell time at each frequency, min
 
 
 
 
M42304
 
5 m / s 2
10m / s 2
15m / s 2
20m / s 2
20m / s 2
25m / s 2
30m / s 2
30m / s 2
10Hz
20Hz
30Hz
40Hz
45Hz
50Hz
60Hz
70Hz
7 minutes
7 minutes
7 minutes
7 minutes
8 minutes
8 minutes
8 minutes
8 minutes
 
M42304 devices ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter in the transport container can withstand without damage the transport shaking with acceleration 30m / s 2, a frequency of 80 to 120 beats per minute for 2 hours;
The devices are manufactured for use in a tropical climate, resistant to mold;
Full range of adjustment as a proofreader at least 2% of the entire length of the scale;
The conditions for a temperate climate for the devices M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter:
- Temperature - from -5 ° C to +40 ° C;
- Relative humidity - 80% at +25 ° C;
The conditions for the tropical climate M42304 devices ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter:
- Temperature - from -50 º C to +60 ° C;
- Relative humidity - less than 100% at a temperature of +35 ° C;
Vibration instruments M42304 ammeters, voltmeters, M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter:
- Acceleration - 5 m / s 2 ... 30 m / s 2;
- Frequency - 10Hz ... 70Hz;
Shock: acceleration of 100m / s 2, the frequency of 10 ... 50 beats per minute;
M42304 devices ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter are nonrecoverable, single-channel, single-function products;
 
System components:
Standard delivery set:
- Instrument - 1pc;
- Nuts and washers for fastening the device to the panel and connect the electrical circuit;
- Wire calibrated KP1 - 1 pair;
- Interchangeable external shunts (as agreed with the customer) - 1;
- Passport - 1ekzemplyar;
- A manual for a lot of devices (in agreement with the customer) - 1 copy;
Note - External shunts and additional resistance to the instruments M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter available for a fee;
 
Design and operation of devices:
- Devices are panel meters magnetoelectric system vnutriramochnym magnet;
- Measuring instruments mechanism of M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter consists of a magnetic system (clip, magnetic) reading device (scale, index) and the movable part in the cores;
Devices are manufactured with a uniform scale, with a zero mark on the edge of or within the measurement range, scale length 60 mm;
Highlighting the scale from an external source of light through the side window cover device;
Body parts M42304 devices ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter are made of plastic and measuring mechanism to protect from contamination, damage and ingestion of dust and spray equipment;
The principle of operation of devices based on the interaction of the magnetic field of permanent magnet with an electric current passing along the winding frame unit;
Set pointer devices M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter zeroed performed by the corrector, which is located on the cover of devices;
 
Placement and installation of:
- The devices are designed for flush mounting on vertical or horizontal panels (panels) made from both magnetic and nonmagnetic materials;
- Installation of equipment must be made ​​carefully, without Perek owls.Mounting devices on the panel must be rigid and not to create the Advanced light sensitivity loads;
- Devices M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivolt during installation should be located away from sources of strong magnetic fields with intensity higher than 0.4 kA / m;
- Before installing the devices on the shield to be believed;
- Connect the equipment M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter to the measured circuit must be made ​​in compliance with the polarity markings in accordance with the current-carrying rods;
- When performing measurements in circuits with instruments and calibration equipment maintenance personnel shall comply with the technical operation and safety in the operation of electrical devices;
The manufacturer guarantees that the equipment technical requirements under the terms of use, storage, transportation and installation;
Shelf life - 12 months from the date of manufacture of devices M42304 ammeter, voltmeter M42304, M42304 micro-ammeter, milliammeter M42304, M42304 millivoltmeter;
Warranty period - 24 months from the date of entry into service of devices.
Gauges Ammeter M42304, M42304 voltmeter, microammeter M42304, M42304 milliammeter, millivoltmeter M42304 comply with the requirements for ensuring safety of life, health, consumer and environmental protection;
To ensure the highest level of service, purchase price is M42304 ammeter will surprise you.
Rate the product: M42304
Number of views: 1969
Product rating: 4.6
Number of grades: 483
* rating and all product statistics are updated once a month; information is current as of 17 December 2024

Photos M42304

M42304 front view (scale).

M42304 front view (scale).

M42304 side view (casing depth).

M42304 side view (casing depth).

M42304 rear view (connection).

M42304 rear view (connection).

Leading online store Zapadpribor - a huge selection of measuring equipment for the best value and quality. So you can buy inexpensive devices, we monitor competitors' prices and are always ready to offer a lower price. We only sell quality products at the best prices. On our site you can buy cheaply as the latest innovations and proven equipment from the best manufacturers.

The site includes a special offer «buy at the best price» - if other Internet resources (bulletin board, forum or announcement of another online service) in products presented on our site, the lower price, we will sell it to you even cheaper! Buyers also additional discount for leaving a review or photo of use of our products.

In the price list contains not the whole range of products offered. Prices of goods, not included in the price list can learn to contact the manager. Also, our managers You can get detailed information about how cheap and profitable to buy instrumentation wholesale and retail. Telephone and e-mail for advice on the purchase , delivery or receipt are shown on the description of the goods. We have the most qualified staff, quality equipment and the best price.

 

Online store Zapadpribor - the official manufacturer's dealer test equipment. Our goal - selling high quality goods with best price offer and service to our customers. Our store can not only sell you the necessary instrument, but also offer additional services to its calibration, repair and installation. That you have a pleasant experience when shopping on our site, we have provided special gifts guaranteed to the most popular products.

 

We offer fast international shipping to almost every country in the world: Australia, Austria, Azerbaijan, Albania, Algeria, Anguilla, Angola, Antigua and Barbuda, Argentina, Aruba,  Bahamas, Bangladesh, Barbados, Bahrain, Belize, Belgium, Benin, Bermuda, Bulgaria, Bolivia, Bonaire, Sint-E. and Saba, Bosnia and Herzegovina, Botswana, Brazil, British Virgin Islands, Brunei Darussalam, Burkina Faso, Burundi, Bhutan, VietNam, Vanuatu, Vatican City, Venezuela, Armenia, Gabon, Guyana, Haiti, Gamia, Gambia, Ghana, Guatemala, Guinea, Gibraltar, Honduras, Hong Kong, Grenada, Greenland, Greece, Georgia, Denmark, Democratic Republic of the Congo, Jersey, Djibouti, Dominica, Dominican Republic, Ecuador, Eswatine, Estonia, Ethiopia, Egypt, Zambia, Zimbabwe, Jordan Indonesia, Ireland, Iceland, Spain, Italy, Cape Verde, Kazakhstan, Cayman Islands, Cambodia, Cameroon, Canada, Qatar, Kenya, Kyrgyzstan, China, Cyprus, Kiribati, Colombia, Comoros, Congo, Korea (Rep.), Costa Rica, Kot-d'Ivoire, Cuba, Kuwait, Curacao, Laos, Latvia, Lesotho, Lithuania, Liberia, Lebanon, Libya, Liechtenstein, Luxembourg, Myanmar, Mauritius, Mauritania, Madagascar, Macao, Malawi, Malaysia, Mali, Maldives, Malta, Morocco, Mexico, Mozambique, Moldova, Monaco, Monaco, Namibia, Nauru, Nepal, Niger, Nigeria, Netherlands, Germany, New Zealand, New Caledonia, Norway, UAE, Oman, Cook Islands, Pakistan, Palestine, Panama, Papua New Guinea, Paraguay, Peru, South Africa, Poland, Portugal, Republic of Chad, Rwanda, Romania, El Salvador, Samoa, San Marino, Saudi Arabia, Swaziland, Seychelles, Senegal, Saint Vincent and the Grenadines, Saint Kitts and Nevis, Saint Lucia, Serbia, Singapore, Sint Maarten, Slovakia, Slovenia, Solomon Islands, United Kingdom of Great Britain and Northern Ireland, Sudan, Suriname, East Timor (Timor-Leste), USA, Sierra Leone, Tajikistan, Taiwan, Thailand, Tanzania (United Republic of), Togo, Tonga, Trinidad and Tobago, Tuvalu, Tunisia, Turkey, Turkmenistan, Uganda, Hungary, Uzbekistan, Uruguay, Faroe Islands, Fiji, Philippines, Finland, France, French Polynesia, Croatia, Central African Republic, Czech Republic, Chile, Montenegro, Switzerland, Sweden, Sri Lanka, Jamaica, Japan.

We also provide such metrological procedure: calibration, tare, graduated, testing of measuring instruments.

The online store takes an active part in such procedures as electronic bidding, tender, auction.

If there is no site in the descriptive information you need on the device you can always turn to us for help. Our qualified managers will update for you on the technical characteristics of the device from its technical documentation: user manual, certificate, form, operating instructions, diagram. If necessary, we will take a photo of your device, or a device stand. You can leave feedback on the unit purchased from us, the meter, the device, indicator, or product. Your review for your approval will be published on the site without contact information.

 

Description of the instruments taken from the technical documentation or technical literature. Most pictures of products made directly by our experts prior to shipment of goods. In the description of the device provided the main technical characteristics of the instrument: nominal measuring range, accuracy class, scale, supply voltage, size (size), weight. If the site you see the discrepancy device name (model) specifications, photo or documents attached - let us know - you will get a useful gift with-selling device.

 

While the need to clarify the overall weight and size or the size of the individual meter you can in our service center. If you need our engineers will help you choose the most complete analog or a suitable replacement for the device you are interested. All counterparts and replacement will be tested in one of our laboratories with the full compliance to your requirements.

In the technical documentation for each device or product, information is provided on the list and amount of precious metals content. The documentation gives the exact weight in grams of precious metals: Au gold, palladium Pd, platinum Pt, silver Ag, tantalum Ta and other platinum group metals (PGM) per unit item. These precious metals are found in nature in very limited quantities and therefore have such a high price.

On our website you can familiarize yourself with the technical characteristics of devices and obtain information on the content of precious metals in devices and radio components manufactured in the USSR. We draw your attention to the fact that often the actual content of precious metals differs by 10-25% from the reference one in a smaller direction! The price of precious metals will depend on their value and mass in grams.

All text and graphic information on the site is informative. The color, shade, material, geometric dimensions, weight, content, delivery set and other parameters of the goods presented on the site may vary depending on the batch of production and year of manufacture. Check with the sales department for more information.

 

If you can make repairs to the device yourself, our engineers can provide you with a complete set of necessary technical documentation: circuit diagram TO, ER, FD, PS. We also have an extensive database of technical and metrological documents: technical specifications (TS), the terms of reference (TOR), GOST (DSTU), the industry standard (OST) test procedure, the method of certification, verification scheme for more than 3,500 types of measuring equipment from the manufacturer this equipment. From the site you can download all the necessary software (the software driver) is required for the product purchased.

We carries out repairs and maintenance of measuring equipment in more than 75 different factories of the former Soviet Union and CIS.

We also have a library of legal documents that are related to our field of activity: the law, code, ordinance, decree, temporary position.