Selsyns, rotary transformers, electric motors >> transformers rotating >> rotating transformers different

VT100

available:
18 pieces
For order is possible effectively delivery of any quantity.
    Transformer VT100 rotating multi two a readout open-frame (VT-100, VT 100, bt-100, bt100, bt 100)
 
    Transformer VT100-6-0,05/0,5-0,13/0,56 rotating multi two a readout open-frame is designed for use in electro-mechanical computing devices, servo systems, as well as the primary sensor to digital converters.
    Depending on the scheme and the inclusion mode (function) devices angle sensors VT-100 divided by sine-cosine (Synchro), output voltage which is proportional to the sine (cosine) the angle of rotation of the rotor, and linear (LVT), the output voltage which varies linearly proportional to the angle of ± 60 °.
Rough count (SC) and the exact count (TO) W type VT100 located on a common magnetic core.
 
    Technical characteristics of the instrument transformers VT100 rotating multi-pole frameless two a readout:
 
    Accuracy Class - 0,3, 0,5, 1;
    Rated voltage excitation - 6V;
    Nominal frequency - 400Hz;
    Operating frequency range - 400Hz-4000Hz;
    The divergence of the null positions of the rotor and TO GO - 15ugl.min;
    Change the position of matching the channel is set, the instrument transformer VT100 when the ambient temperature at every 40°C - 12ugl.s;
    Electric reduction canal TO - 32;
    Type VTDP receiver, which operates the instrument transformer VT100 rotating multi two a readout open-frame - BT-5 KFZ.031.055;
    Steepness in the mode of TPD, channels:
    - TO - 5mV/ugl.min.;
    - GO - 1,3mV/ugl.min.;
    The ratio of residual EDS to steepness, channel:
    - TO - 0,6ugl.min.;
    - GO - 25ugl.min.;
    Phase shift of the output emf of channels:
    - TO - 85ugl.grad.;
    - GO - 25ugl.grad.;
    Rated current excitation instrument transformer VT100:
    - TO - 115mA;
    - GO - 12mA;
    Maximum output voltage:
    - Channel TO - 0,75V;
    - Channel GB - 3,4V.
    The number of pairs of poles (electric reduction):
    - Channel TO - 32;
    - Channel GO - 1.
    The error of the channel following the instrument angle sensor VT-100 at a frequency of 4000Hz excitation voltage can vary by 15° compared to the error, measured at a frequency of 400Hz;
    The greatest number of VTDP receivers, which may be connected to a single sensor - 2;
    Operation - Synchro (TO), VTDP-D (GO);
    Transformers rotating multi-pole frameless two a readout VT100 are divided into accuracy classes:
    - Transformer VT100 accuracy class 0.3 (0.3 cl. T) has the characteristics:
     - Accuracy of following channel MOT - ± 0,3 ang.;
     - Accuracy of following channel GO - ± 15 ang.;
    - Transformer VT100 0.5 accuracy class (0.5 cl. T) has the characteristics:
     - Accuracy of following channel MOT - ± 0,5 ang.;
     - Accuracy of following channel GO - ± 15 ang.;
    - Transformer VT100 precision class (1st class. Etc.) has the characteristics:
     - Accuracy of following channel MOT - ± 1 ang.;
     - Accuracy of following channel GO - ± 15 ang.;
 
    Vibration loads:
    - Frequency range - up to 2000Hz;
    - Acceleration - 200m / s 2;
    Shock - 1500m / s 2;
    Ambient temperature - -60°C to +100 º C;
    Relative humidity at 35°C - 98%;
    Overall dimensions transformer VT100 rotating multi two a readout open-frame:
    - Outer diameter - 100mm;
    - Inside diameter - 60mm;
    Weight - 0,4kg;
    Warranty life instrument angle sensor VT-100 - 10,000 hours.

Photos VT-100

VT100-6-0,05/0,5-0,13/0,56 device image.
VT100-6-0,05/0,5-0,13/0,56 device image.
VT100-6-0,05/0,5-0,13/0,56 accessories and spare parts.
VT100-6-0,05/0,5-0,13/0,56 accessories and spare parts.
VT100-6-0,05/0,5-0,13/0,56 device image coarse counting.
VT100-6-0,05/0,5-0,13/0,56 device image coarse counting.
VT100-6-0,05/0,5-0,13/0,56 coarse counting front view.
VT100-6-0,05/0,5-0,13/0,56 coarse counting front view.
VT100-6-0,05/0,5-0,13/0,56 coarse counting side view.
VT100-6-0,05/0,5-0,13/0,56 coarse counting side view.
VT100-6-0,05/0,5-0,13/0,56 coarse counting rear view.
VT100-6-0,05/0,5-0,13/0,56 coarse counting rear view.
VT100-6-0,05/0,5-0,13/0,56 device image accurate counting.
VT100-6-0,05/0,5-0,13/0,56 device image accurate counting.
VT100-6-0,05/0,5-0,13/0,56 coarse counting front view.
VT100-6-0,05/0,5-0,13/0,56 coarse counting front view.
VT100-6-0,05/0,5-0,13/0,56 coarse counting side view.
VT100-6-0,05/0,5-0,13/0,56 coarse counting side view.
VT100-6-0,05/0,5-0,13/0,56 coarse counting rear view.
VT100-6-0,05/0,5-0,13/0,56 coarse counting rear view.


Яндекс цитирования