V7-16A V7-16A Voltmeter universal V7-16A
4.9 63

Voltmeter universal V7-16A (V716A, V-7-16-A, V 7 16 A, b7-16a, V-716A, V 716A, b716a, b-7-16a, b 7 16a, b-716a, b 716a)

Designed to measure DC and AC current and resistance in the routine, repairs and adjustments in various fields of electronics and appliances for testing the lower class;
The ranges of measured values:
- DC - 1 ∙ 10 -4 V-1000 V;
- AC voltage:
- In the frequency range from 20Hz to 20kHz - 1 ∙ 10 -4 V-1000 V;
- In the frequency range from 20 kHz to 50 MHz (with a high-converter) - 0.1 B-1B;
- In the frequency range from 20 kHz to 30 MHz (with a high-converter and splitter 1:10) - 1V to 10V;
- Resistance - 0.1 ohms, July 10 ohms;
Dimensions - 348h128h360mm.
Radiometric devices
voltmeters (V2-, V3-, V4-, V7-, V8-, V9-, F and others)

Price:

on request

 

Product information updated 10 December 2023.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

Product information updated 10 December 2023.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

Technical characteristics

Voltmeter universal V7-16A (V716A, V-7-16-A, V 7 16 A, b7-16a, V-716A, V 716A, b716a, b-7-16a, b 7 16a, b-716a, b 716a)

Voltmeter universal V7-16A designed to measure DC and AC currents and resistance in the routine, repairs and adjustments in various fields of electronics and appliances for testing the lower class.
Technical characteristics of the instrument voltmeter universal V7-16A:
The ranges of measured values:
- DC - 1 ∙ 10 -4 V-1000 V;
- AC voltage:
- In the frequency range from 20Hz to 20kHz - 1 ∙ 10 -4 V-1000 V;
- In the frequency range from 20 kHz to 50 MHz (with a high-converter) - 0.1 B-1B;
- In the frequency range from 20 kHz to 30 MHz (with a high-converter and splitter 1:10) - 1V to 10V;
- Resistance - 0.1 ohms, July 10 ohms;
The device V7-16A is designed for use in laboratory and shop floor, the power may be exercised only on AC power;
Normal conditions of use of the instrument are:
- Ambient temperature - 293 K ± 5 K (20 º C ± 5 º C);
- Relative humidity - 65% ± 15%;
- Atmospheric pressure - 100 kPa ± 4kPa (750mm.rt.st. ± 30mm.rt.st.);
- Supply voltage - 220 V ± 4,4 V;
- Power frequency - 50 Hz ± 0,5 Hz 400 Hz ± 12 Hz;
- Shape of the AC mains voltage - sinusoidal, THD less than 5%;
Time measurement of DC voltage at the input filter off B7-16A should be:
- 200 ms at 100 ms conversion time and a four-digit numerical count;
- 40ms 20ms conversion time in and a four-digit readout;
- 2 ms at 1 ms conversion time and the three-digit digital readout;
Time measurement of DC voltage V7-16A when the input filter must be no more than 5 seconds, the measurement of AC voltage, resistance should be less than 10 s;
Measuring ranges of electrical quantities correspond to the values ​​specified in Table. 1;
Ranges divided into subbands indicated in Table. 1;
Selection of sub-band measurements carried out by hand;
Selecting the polarity when measuring DC voltage is automatic;
The measurement is as indicated in Table. 1;
 
Table 1 Ranges of electrical quantities B7-16A
 
Measurand
The limits of measurement
The measurement resolution
DC voltage with a conversion time 20ms and 100ms
1B
10B
100B
1000V
1 ∙ 10 -4 V
1 ∙ 10 -3 V
1 ∙ 10 -2 V
1 ∙ 10-1V
DC voltage with a conversion time 1ms
1B
10B
100B
1000V
1 ∙ 10 -3 V
1 ∙ 10 -2 V
1 ∙ 10-1V
1B
AC voltage at a conversion time of 100 ms
   
in the frequency range of 20Hz-20kHz
1B
1 ∙ 10 -4 V
in the frequency range of 20Hz-20kHz
10B
100B
1000V
1 ∙ 10 -3 V
1 ∙ 10 -2 V
1 ∙ 10-1V
in the frequency range of 20kHz-50kHz
1B
1 ∙ 10 -4 V
in the frequency range of 50kHz-100kHz
1B
1 ∙ 10 -4 V
in the frequency range of 100 kHz-50 kHz (with high-frequency converter)
1B
1 ∙ 10 -4 V
in the frequency range 20kHz-30kHz (with a high frequency inverter and divider 1:10)
10B
1 ∙ 10 -3 V
A resistance at conversion time 20ms and 100ms
1K
10k
100 k
1000 ohms
10 M
1 ∙ 10 -4 ohm
1 ∙ 10 -3 ohm
1 ∙ 10 -2 ohm
1 ∙ 10 -1 ohm
1K

 

Measurand
The limit of permissible relative basic error
Change measurand inlet voltmeter within subband
DC voltage with a conversion time 20ms and 100ms
± [0,1 +0,05 (| U to / U x | -1)]%
1 ∙ 10 -4 B-1B
1 ∙ 10 -3 V to 10 V
1 ∙ 10 -2 V-100B
1 ∙ 10-1V-1000V
DC voltage with a conversion time 1ms
± [0,2 +0,1 (| U to / U x | -1)]%
1 ∙ 10 -3 V to 10 V
1 ∙ 10 -2 V-100B
1 ∙ 10-1V-1000V
1B-100B
AC voltage at a conversion time of 100 ms
   
in the frequency range of 20Hz-20kHz
± [0,2 +0,05 (| U to / U x | -1)]%
1 ∙ 10 -4 B-1B
in the frequency range of 20Hz-20kHz
± [0,5 +0,05 (| U to / U x | -1)]%
1 ∙ 10 -3 V to 10 V
1 ∙ 10 -2 V-100B
0.1 In-1000V
in the frequency range of 20kHz-50kHz
± [1 +0,1 (| U to / U x | -1)]%
1 ∙ 10 -4 B-1B
in the frequency range of 50kHz-100kHz
± [1,5 +0,1 (| U to / U x | -1)]%
1 ∙ 10 -4 B-1B
in the frequency range of 100 kHz-50 kHz (with high-frequency converter)
± [4 +1,5 (| U to / U x | -1)]%
0.1 B-1B
in the frequency range 20kHz-30kHz (with a high frequency inverter and divider 1:10)
± [4 +1,5 (| U to / U x | -1)]%
1B-10B
A resistance at conversion time 20ms and 100ms
± [0,2 +0,05 (| R a / R x | -1)]%
1 ∙ 10 -4 ohm-1 k
1 ∙ 10 -3 ohm-10k
1 ∙ 10 -2 ohm-100k
0.1 k-1000 k
1 kW to 10 MW

 

where U to - the final value of the set sub-band measurements of AC voltages;
U's - the voltmeter reading.
Frequency range AC voltage measured by a voltmeter should be:
- For sub-band "1" from 20Hz to 100kHz, 100kHz to 50MHz from a high-frequency transducer;
- For sub-band "10" 20Hz to 20kHz, 20kHz to 30MHz from a high-frequency transducer and the divider 1:10;
- For sub-band "100", "1000" ot20Gts to 20kHz;
When measuring AC voltage voltmeter V7-16A has graduated in the RMS values ​​of a sinusoidal voltage. The basic error of the voltmeter should be provided when measuring the voltage sine wave in the frequency range from 20 Hz to 100 kHz with harmonic content not exceeding 0.1% at the limit of 1B and not more than 0.2% for the rest of the range. In the frequency range from 100 kHz to 50 MHz basic error of the voltmeter should be provided with harmonic content in the measured voltage of less than 1%;
Authorities set the value of the calibration voltage change must ensure the calibration voltage within ± 50 characters stamped on the nameplate. The value of the calibration voltage on the rating plate must be in the 9,1 ± 0,5 V;
In the voltmeter V7-16A provides overload indicator;
Voltmeter provides the following startup modes:
- Automatically by the internal power pulses with a repetition period of 0.1 s-5s at conversion time 20ms and 1ms, with 0.2-5c at 100 ms conversion time;
- Manually by pressing;
- Remote from the external power pulses of up to 1 kHz, 50 Hz, 10 Hz, respectively;
The limit of permissible relative basic error voltmeter V7-16A Percentage measurement of DC voltage of either polarity at conversion time 1ms, 20ms and 100ms must comply tab. 1;
Rejection Ratio sinusoidal type serial synchronous with the mains frequency of 50Hz equal to 100ms if the conversion time is not less than 40dB and conversion time of 20ms at least 30dB in the measurement mode and the DC voltage off filter. Sum of the peak value of interference voltage and the measured voltage must not exceed 120% of the prescribed limit of measurement;
Voltmeter V7-16A has a built-in filter for additional noise reduction serial form in voltage mode DC. Interference suppression unit, synchronous with the mains frequency equal to 50 Hz, with a conversion time 20 ms and 100 ms in the case included the filter is at least 60 dB;
The limit of permissible relative basic error voltmeter percent when measuring AC voltage with a conversion time 100ms must conform to Table 1;
The limit of permissible relative basic error in the measurement protsentax resistance at conversion time 20ms and 100ms must conform to Table 1;
Power dissipation V7-16A on the measured resistance is less than 25 MW;
The limit of additional error from ambient temperature changes in all types of measurement should not exceed half of the basic error limit for each 10 ° C change in temperature. The limit of additional error from the effects of high humidity should not exceed the limit of the basic error;
The limit of additional error for all types of: measuring the drift time is ± 15 counts for 10 hours (without periodic zero and calibration);
Input impedance voltmeter V7-16A is:
- Not less than 10 MW in the measurement of the DC voltage;
- At least 1 Mohm when measuring AC voltage and high-frequency transducer with a divider 1:10;
Input capacitance of the voltmeter when measuring AC voltage does not exceed 100 pF. Input capacitance of the high-frequency converter, and a high-frequency transducer with a divider 1:10 - no more than 10 pF;
Voltmeter V7-16A has an output to an external device tsifropechatayuschee. Output code signal corresponding to a logic zero, the voltage level is less than ± 0,3 V. Output code signal corresponding to a logic one voltage level is not less than 2.4 V at not less than 10 ohms;
Voltmeter provides its specifications after time samoprogreva for 1 hour under normal conditions and 2 hours in a high humidity;
Meals voltmeter V7-16A is powered by the AC voltage of 220V ± 22V 50Hz ± 0,5 Hz 220V ± 11V and 115V voltage of ± 5,75 V, frequency 400 Hz ± 12 Hz and harmonic content up to 5%;
The power consumed by the device from the network at the maximum supply voltage must not exceed 35V ∙ A;
Voltmeter V7-16A allows for continuous operation in the working conditions for a time at least 16 hours while maintaining its specifications within the rules;
Dimensions - 348h128h360mm;
Weight V7-16A - no more than 7kg.
Rate the product: V7-16A
Number of views: 2191
Product rating: 4.5
Number of grades: 341
* rating and all product statistics are updated once a month; information is current as of 27 December 2023

Photos: V7-16A

V7-16A voltmeter image.

V7-16A voltmeter image.

V7-16A front view.

V7-16A front view.

V7-16A side view.

V7-16A side view.

V7-16A rear view.

V7-16A rear view.

V7-16A overhead view.

V7-16A overhead view.

V7-16A bottom view.

V7-16A bottom view.

Leading online store Zapadpribor - a huge selection of measuring equipment for the best value and quality. So you can buy inexpensive devices, we monitor competitors' prices and are always ready to offer a lower price. We only sell quality products at the best prices. On our site you can buy cheaply as the latest innovations and proven equipment from the best manufacturers.

The site includes a special offer «buy at the best price» - if other Internet resources (bulletin board, forum or announcement of another online service) in products presented on our site, the lower price, we will sell it to you even cheaper! Buyers also additional discount for leaving a review or photo of use of our products.

In the price list contains not the whole range of products offered. Prices of goods, not included in the price list can learn to contact the manager. Also, our managers You can get detailed information about how cheap and profitable to buy instrumentation wholesale and retail. Telephone and e-mail for advice on the purchase , delivery or receipt are shown on the description of the goods. We have the most qualified staff, quality equipment and the best price.

 

Online store Zapadpribor - the official manufacturer's dealer test equipment. Our goal - selling high quality goods with best price offer and service to our customers. Our store can not only sell you the necessary instrument, but also offer additional services to its calibration, repair and installation. That you have a pleasant experience when shopping on our site, we have provided special gifts guaranteed to the most popular products.

 

We offer fast international shipping to almost every country in the world: Australia, Austria, Azerbaijan, Albania, Algeria, Anguilla, Angola, Antigua and Barbuda, Argentina, Aruba,  Bahamas, Bangladesh, Barbados, Bahrain, Belize, Belgium, Benin, Bermuda, Bulgaria, Bolivia, Bonaire, Sint-E. and Saba, Bosnia and Herzegovina, Botswana, Brazil, British Virgin Islands, Brunei Darussalam, Burkina Faso, Burundi, Bhutan, VietNam, Vanuatu, Vatican City, Venezuela, Armenia, Gabon, Guyana, Haiti, Gamia, Gambia, Ghana, Guatemala, Guinea, Gibraltar, Honduras, Hong Kong, Grenada, Greenland, Greece, Georgia, Denmark, Democratic Republic of the Congo, Jersey, Djibouti, Dominica, Dominican Republic, Ecuador, Eswatine, Estonia, Ethiopia, Egypt, Zambia, Zimbabwe, Jordan Indonesia, Ireland, Iceland, Spain, Italy, Cape Verde, Kazakhstan, Cayman Islands, Cambodia, Cameroon, Canada, Qatar, Kenya, Kyrgyzstan, China, Cyprus, Kiribati, Colombia, Comoros, Congo, Korea (Rep.), Costa Rica, Kot-d'Ivoire, Cuba, Kuwait, Curacao, Laos, Latvia, Lesotho, Lithuania, Liberia, Lebanon, Libya, Liechtenstein, Luxembourg, Myanmar, Mauritius, Mauritania, Madagascar, Macao, Malawi, Malaysia, Mali, Maldives, Malta, Morocco, Mexico, Mozambique, Moldova, Monaco, Monaco, Namibia, Nauru, Nepal, Niger, Nigeria, Netherlands, Germany, New Zealand, New Caledonia, Norway, UAE, Oman, Cook Islands, Pakistan, Palestine, Panama, Papua New Guinea, Paraguay, Peru, South Africa, Poland, Portugal, Republic of Chad, Rwanda, Romania, El Salvador, Samoa, San Marino, Saudi Arabia, Swaziland, Seychelles, Senegal, Saint Vincent and the Grenadines, Saint Kitts and Nevis, Saint Lucia, Serbia, Singapore, Sint Maarten, Slovakia, Slovenia, Solomon Islands, United Kingdom of Great Britain and Northern Ireland, Sudan, Suriname, East Timor (Timor-Leste), USA, Sierra Leone, Tajikistan, Taiwan, Thailand, Tanzania (United Republic of), Togo, Tonga, Trinidad and Tobago, Tuvalu, Tunisia, Turkey, Turkmenistan, Uganda, Hungary, Uzbekistan, Uruguay, Faroe Islands, Fiji, Philippines, Finland, France, French Polynesia, Croatia, Central African Republic, Czech Republic, Chile, Montenegro, Switzerland, Sweden, Sri Lanka, Jamaica, Japan.

We also provide such metrological procedure: calibration, tare, graduated, testing of measuring instruments.

The online store takes an active part in such procedures as electronic bidding, tender, auction.

If there is no site in the descriptive information you need on the device you can always turn to us for help. Our qualified managers will update for you on the technical characteristics of the device from its technical documentation: user manual, certificate, form, operating instructions, diagram. If necessary, we will take a photo of your device, or a device stand. You can leave feedback on the unit purchased from us, the meter, the device, indicator, or product. Your review for your approval will be published on the site without contact information.

 

Description of the instruments taken from the technical documentation or technical literature. Most pictures of products made directly by our experts prior to shipment of goods. In the description of the device provided the main technical characteristics of the instrument: nominal measuring range, accuracy class, scale, supply voltage, size (size), weight. If the site you see the discrepancy device name (model) specifications, photo or documents attached - let us know - you will get a useful gift with-selling device.

 

While the need to clarify the overall weight and size or the size of the individual meter you can in our service center. If you need our engineers will help you choose the most complete analog or a suitable replacement for the device you are interested. All counterparts and replacement will be tested in one of our laboratories with the full compliance to your requirements.

In the technical documentation for each device or product, information is provided on the list and amount of precious metals content. The documentation gives the exact weight in grams of precious metals: Au gold, palladium Pd, platinum Pt, silver Ag, tantalum Ta and other platinum group metals (PGM) per unit item. These precious metals are found in nature in very limited quantities and therefore have such a high price.

On our website you can familiarize yourself with the technical characteristics of devices and obtain information on the content of precious metals in devices and radio components manufactured in the USSR. We draw your attention to the fact that often the actual content of precious metals differs by 10-25% from the reference one in a smaller direction! The price of precious metals will depend on their value and mass in grams.

All text and graphic information on the site is informative. The color, shade, material, geometric dimensions, weight, content, delivery set and other parameters of the goods presented on the site may vary depending on the batch of production and year of manufacture. Check with the sales department for more information.

 

If you can make repairs to the device yourself, our engineers can provide you with a complete set of necessary technical documentation: circuit diagram TO, ER, FD, PS. We also have an extensive database of technical and metrological documents: technical specifications (TS), the terms of reference (TOR), GOST (DSTU), the industry standard (OST) test procedure, the method of certification, verification scheme for more than 3,500 types of measuring equipment from the manufacturer this equipment. From the site you can download all the necessary software (the software driver) is required for the product purchased.

We carries out repairs and maintenance of measuring equipment in more than 75 different factories of the former Soviet Union and CIS.

We also have a library of legal documents that are related to our field of activity: the law, code, ordinance, decree, temporary position.