Radiometric devices >> voltmeters

V3-63

79 999 RUB
33 599 UAH
available:
1 piece

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Voltmeter V3-63 AC (V363, V-3-63, V 3 63, V-363, V 363)
 
Voltmeter V3-63 AC is designed to measure the rms AC voltage sine wave.
Used as working and exemplary means of measuring for verification and calibration of electronic voltmeters, a standard signal generator and calibrators for the output voltage. Has embedded microcontroller.
In addition to the direct measurement of the voltage in the device includes modes:
- Determination of the relative difference (in percentage and dB) of the measured voltage level defined by;
- Automatic calibration and zeroing, self-control device and diagnostics of components, work in AIS by the CPC.
 
Technical characteristics of the devices voltmeters V3-63 AC:
 
Measurement range Voltage - 0.01V-100V (-27 dB, 53 dB);
Measuring range of the relative difference of the measured and the reference voltage of the device voltmeter V3-63 AC - 9.99% - 9.99% (-0.914 0.827 dB-dB);
Maximum permissible error in the measurement of stress in the normal range of frequencies:
- In the sub-band measurement of 0.01 V to 10 V instrument voltmeter V3-63 AC:
- At 0.05 - ± 1,8%;
- At 0.1 V - ± 1%;
- At the level 1B - ± 0,27%;
- At 10 V - ± 0,2%;
- In the sub-band measurement of 10V-100V voltmeter unit V3-63 AC:
- At 10 V - ± 0,2%;
- At 50V - ± 0,2%;
- At 100 V - ± 0,2%;
Setting range voltage reference device AC voltmeter V3-63 - 0.1000-100, 0V;
The error in the measurement of the relative voltage difference:
- When the measured voltage 0.1 V - ± 1%;
- When the measured voltage to 0.9001 - 9,99% ± 0,37%;
- When the measured voltage 1.0 V - ± 0,27%;
- When the measured voltage to 1.0999 - 9,99% ± 0,37%;
- When the measured voltage 100V - ± 0,2%;
Mean time to failure of the device voltmeter V3-63 AC - not less than 5500 hours;
Gamma-percent life - at least 10,000 hours at γ = 95%;
Gamma-percent service life - at least 10 years at γ = 95%;
Gamma-percent shelf life - at least 10 years for heated storage or 5 years for non-heated storage at γ = 90%;
Power supply voltage meter V3-63 AC - AC 220V ± 22V, 50Hz ± 0,5 Hz or 220V ± 11V, ± 400 Hz frequency 12Gts;
Power consumed by the device - 100B ∙ A;
Overall dimensions voltmeter V3-63 AC - 490h175h510mm;
Weight - 22.5 kg;
The manufacturer guarantees that the quality of the instrument voltmeter V3-63 AC technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.

Photos: V3-63