Radiometric devices >> voltmeters

V3-39 Millivoltmeter analog AC V3-39

V3-39

8 999 RUB
7 199 UAH
available:
10 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Millivoltmeter analog AC V3-39 (V3 39, V339, Vз-39, b3-39, b3 39, b339)
Measurement of a sinusoidal voltage of of alternating current.
Use as a voltage converter or a broadband amplifier.
Measuring range 100mkv - 300V, frequency range 20Hz - 10MHz.
Error of 2,5-15%. Bx. Pair., cap.: 4MOm, and 1M 30pF, 15pF (with a divider).
152h206h300mm dimensions, weight 5kg.

Millivoltmeter analog AC V3-39 is designed for measuring a sinusoidal AC voltage of 0.1 mV to 300 V in the frequency range from 20 Hz to 10 MHz. The readings are proportional to the mean, and the range is scaled to the effective values ​​of sinusoidal voltage. Millivoltmeter analog AC V3-39 has a separate scale is graduated in decibels. Level "0" dB is 0.775 V. The device can be used as an AC voltage to DC in terms of the effective value of a sine wave.

To the unit Millivoltmeter analog AC V3-39 is attached to a voltage divider DN-108 with the division ratio 1:10, which allows to reduce the capacity supplied to the measuring point.

Technical characteristics
 
Options
The values
The measured voltage
Range
0.1 mV-300V
Subranges
1mV/3mV/10mV/30mV/100mV /
300mV /
1V/3V/10V/30V/100V/300V
Frequency range of the measured voltage
to within 3mV-300
20Hz-10MHz
at the limit of 1 mV
20 Hz to 5 MHz

The basic error of in the Percentage from the upper limit the established sub-band of measurement in the normal region of frequencies 45Hz-1MHz increment

Without divider
at the limits of measurement 3mV-1B
± 2.5%
for measurement within 1 mV, 3V-300V
± 4%
On the divisor DN-108
at the limits of measurement 3mV-1B
± 4%

Active impedance measured at a frequency of 55 Hz

Without divider
4MOm
On the divisor DN-108
1M
Input capacitance
Without divider
at the limits of measurement
1 mV, 1 V
30pF
 
at the limits of measurement
3B-300V
15pF
On the divisor DN-108

Allowable stresses the value of the sum of dc and rms value of the measured voltage

350 V
Warm-up time
5 min
Mean time between failures
Of 2,500 hr
Broadband amplifier output

The output voltage at full deflection indicator

at the limits of of measurement gain 3mV-300 In the
150 mV ± 15%
at the limit of measurement of 1 mV
110 mV ± 15%
Output resistance
50 ohms
Frequency band
20 Hz to 5 MHz
Operating conditions
Environment temperature
+10 - +35 ° C
Relative humidity
up to 80% at +20 ° C
Atmospheric pressure
750 ± 30 mm Hg. Art.
Supply voltage
220 V ± 10% / 50 Hz ± 1%
General characteristics
Power consumption
Consumption 20VA
Overall dimensions
155 x 210 x 300 mm
Weight
5 kg
         
 
The basic error of measurement in%
 
Range
Operating frequency range

Normal
frequency range
45 Hz to 1 MHz

Operating frequency range
20-30 Hz
30-45 Hz
1-3 MHz
3-5 MHz
5-10 MHz
1 mV
± 10,0
± 6,0
± 4,0
± 6,0
± 10,0
-
3mV-1
± 6,0
± 4,0
± 2,5
± 4,0
± 6,0
3B-300V
± 10,0
± 6,0
± 4,0
± 6,0
± 10,0

With divider
DN-108

1 mV
± 15,0
± 10,0
± 6,0
± 10,0
± 15,0
-
3mV-1B
± 10,0
± 6,0
± 4,0
± 6,0
± 10,0