Millivoltmeter V3-36 analog AC with a diode input (V3 36, V336, Vз-36, b3-36, b3 36, b336)
The measurement of high-voltage sine wave.
The range of the voltage measuring 3mV - 3V to 300V (with external divider)
frequency range of 10 kHz - 1000 MHz, the error of 4-25%;
input. Pair. 80kOm (20MHz), 35kOm (100MHz), 10K (10 kHz and with a divider);
input. cap. 1.5 pF, 3.5 pF (with a divider).
318h206h328mm dimensions, weight 12kg.

Millivoltmeter V3-36 analog AC is designed to measure the rms sinusoidal voltage of 3 mV to 3 in the frequency range from 10 kHz to 1000 MHz and with external divider DN-111 and DN-112 (dividing ratio 1:100) of 3 to 300 in the frequency range from 10 kHz to 300 MHz.


Specifications, Millivoltmeter V3-36 analog AC
The range of the measured voltages: No divider 3 mV 3, Sub-bands 10/30/100/300 mV / third, C external divider DN-112 and DN-111 3-300 In
First rabochayaoblast frequency of the measured voltages
Without divider 10-30 MHz, with a divider DN-112 10-500 kHz, with a divider DN-111 500 kHz to 30 MHz.
Frequency range of the measured voltages without divider 30-1000 MHz, with a divider DN-111 30-300 MHz. The variation of readings ≤ (± 1%).
Maximum permissible error of the instrument, as a percentage of the upper limit of the established sub-band. In subbands measurement range 30 mV 3 ≤ (± 4.0%). In subband measurement limit 10 mV ≤ (± 6.0%). With the voltage dividers ≤ (± 6.0%). Frequency of calibration of the instrument and the divider DN-112 - 100 kHz. The frequency of calibration divider DN-111 - 1 MHz.
Acceptable input voltage. Constant ≤ 150, the sum of a constant component and the measured voltage ≤ 450 V Input resistance. On the outside of the subbands 1 ... 3 and divider DN-111 at all subbands at 20 MHz ≥ 80 ohm at 100 MHz ≥ 35 ohms. The input impedance of the instrument V3-36 on the sub-bands below 1 V is not standardized. Input capacitance on the outside of the ranges with a 1 ... 3 - ≤ 1.5 pF. Input capacitance with divisors DN-111 and DN-112 in all sub-bands ≤ 3.5 pF. SWR tee junction with a characteristic impedance of 50 ohms and 75 for frequencies up to 1000 MHz ≤ 1.3.
Response time ≤ 4 with the device. Time samoprogreva 15 minutes. Operating conditions. The air temperature +5 ... +40 ° C. Relative humidity 95% at a temperature of +30 ° C. Atmospheric pressure 100 ± 4 kPa (750 ± 30 mm Hg. Centuries). Mains AC ~ 220 ± 22, 50 ± 0.5 Hz or 220 V ± 11, 400 +28 / -12 Hz.
Power consumption ≤ 45 · A.
Time to failure ≥ 5000 h
Overall dimensions 328 × 318 × 206 mm.
Weight with lids ≤ 12 kg.

Photos: V3-36

V3-36 device image.
V3-36 device image.
V3-36 device image with the closed lid.
V3-36 device image with the closed lid.
V3-36 front view.
V3-36 front view.
В3-36 side view.
В3-36 side view.
V3-36 rear view.
V3-36 rear view.
V3-36 overhead view.
V3-36 overhead view.
V3-36 bottom view.
V3-36 bottom view.


Яндекс цитирования