Programmable device V1-13 for testing voltmeters (V113, V1 13, b1-13, b1 13, b113)

Designed for testing electrical appliances DC.
The output impedance of 0,001 ohms.
The maximum load current is 110 mA at voltages up to 100 V and 11 mA at a voltage up to 1000V.
The drift of the output voltage (in percent) for 8 hours is not more than ± (0,002 + 0,00015 Uc / U), for 2000 hours no more than ± (0,004 + 0,0004 Uc / U).

Programmable device V1-13 for testing voltmeters designed for testing electrical appliances DC in automated verification systems.
In manual mode programmable device V1-13 for testing voltmeters can be used as a standalone verification tools, as well as a wide-range digital-to-analog converter.
The instrument is V1-13 is remotely controlled by signals in the positional code 8-4-2-1.
The output unit V1-13 isolated from the body and from the control circuits on the operating voltage of 1000 V.
Specifications, Devices V1-13
Main technical characteristics of the programmable device V1-13 for testing voltmeters mode calibrated voltages and are shown in Table below.
The output impedance of 0,001 ohms.
The maximum load current is 110 mA at voltages up to 100 V and 11 mA at a voltage up to 1000V.
The drift of the output voltage (in percent) for 8 hours is not more than ± (0,002 + 0,00015 Uc / U), for 2000 hours no more than ± (0,004 + 0,0004 Uc / U).
The device parameters V1-13 in the calibrated current source mode: setting range of calibrated values ​​of the current 1nA-100mA on the subbands 1 mA, 10 mA and 100 mA, the basic error (in percentage) setting the current ± (0,015 + 0,001 Ik / I); maximum voltage on 1000 at load currents up to 100 mA and 10 V at a current above 10 mA.
Time of establishment of the voltage and current with an accuracy of ± 0,001% less than 5 seconds.
Power consumption 100 VA. Dimensions 490 x215x 475mm, weight no more than 25 kg.
Programmable device V1-13 for testing voltmeters meet TU HV2.085.008.
 
Output voltage range The basic error of the output voltage,%
with respect to e. emf. taking into account the measures e. emf.
10mkV-10V ± (0,001 +0,0004 Uc / U) ± (0,005 +0,0004 Uc / U)
100mkV-100B ± (0,002 +0,0005 Uc / U) ± (0,005 +0,0005 Uc / U)
1mV-100V

± (0,0025 +0,0005 Uc / U) - for

U ≤ 500 V; ± 0,005 - at U> 500 V

± (0,006 +0,0005 Uc / U) - for

U ≤ 500 V; ± 0,01 - at U> 500 V