Electrical measuring instruments >> transformers laboratory >> current transformers

UTT-6M1 Current transformer UTT-6M1 measuring laboratory.

UTT-6M1

9 999 RUB
4 000 UAH
available:
55 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
The current transformer UTT-6M1 measuring laboratory (UTT6M1, UTT-6-M1, UTT 6 M1, UTT 6M1, UTT6-M1, UTT6 M1)
 
The current transformer UTT-6M1 measuring laboratory is designed for use in AC circuits in the electrical measurement and calibration instruments.
 
Technical characteristics of the instrument current transformers UTT-6M1 measuring laboratory:
 
Accuracy class - 0.2;
The normal frequency current transformer device UTT-6M1 measuring lab - 50Hz;
Nominal value of the force of the primary current - 100A, 150A, 200A, 250A, 300A, 400A, 500A, 600A, 750A, 800A, 1000A, 1200A, 1500A, 2000A;
The nominal value of the secondary load current transformer measuring device UTT-6M1 laboratory - 10 (with cosφ from 0,8 to 1);
Maximum permissible errors:
- Current - ± (0,2 +0,04 (Іn/І-1))%;
- Angle - ± (10 + 1 (Іn/І-1));
The nominal value of the secondary current - 5A;
Rated voltage instrument transformer primary winding current UTT-6M1 measuring laboratory relative to the body and the secondary winding - 660V;
Continuous operation - no more than 8 hours;
A break to re-enable the device current transformer UTT-6M1 measuring lab - at least 30 minutes;
Overall dimensions - no more 236h190h78mm;
Diameter of central hole - not less than 80mm;
Weight of the device current transformer UTT-6M1 measuring lab - no more than 3.8 kg.
 