    Combined portable device TS4380
    Also, this device can be called: C 4380, C-4380.
 
    Ts4380 portable device intended for combined measurements of DC, AC and pulse current.
    Accuracy class - 1.5 , 2.5, 5.0 .
    Limits of measurement :
    - The power of DC, AC and pulse current - from 0.006 A to 15 A;
    - A DC voltage and a pulsed DC current direction - from 0.075 V to 600 V;
    - AC voltage and the AC pulse current direction - from 0.3 V to 600 V;
    - DC resistance - from 100 ohms to 1 Mohm .
    Pulse width - from 0.21 to 0.62 sec.
    Tester TS4380 is equipped with a protection circuit against electrical overload.
 
    Specifications:
 
    Ranges - 100 ohms, 1000 ohms.
    Internal voltage electrochemical power source - from 3.7 V to 4.7 V.
    Voltage of the external power source to the detection limit in 1000 ohm - from 34 V to 44 V.

Limits of measurement:
    - The power of DC, AC and pulse current - 0.006 A, 0.03 A, 0.15 A, 0.6 A, 1.5 A, 3 A, 6 A, 15 A;
    - A DC voltage and a pulsed DC current direction - 0.075 V, 0.3 V, 1.5 V, 6 V, 15 V, 30 V, 150 V, 300 V, 600 V;
    - AC voltage and the AC pulse current direction - 0.3 V, 1.5 V, 6 V, 15 V, 30 V, 150 V, 300 V, 600 V;
    - DC resistance - 100 ohms, 10 ohms, 100 ohms, 1 Mohm.
    Pulse width - from 0.21 to 0.62 sec.
    Pauses - from 0.11 to 0.81 with a.
    Pulse envelope - close to rectangular.
    Accuracy:
    - DC current - ± 1,5%;
    - DC voltage - ± 1,5%;
    - AC power - ± 2,5%;
    - AC voltage - ± 2,5%;
    - Power and voltage pulsed AC and DC areas - ± 5,0%.
    Current full deviation when the voltage, the voltage drop at the terminals when the testers TS4380 current and power consumption of electrochemical sources listed in Table 1.
 
    Table 1
Type of current
Limits of measurement
Voltage drop in
Full-scale deflection current, mA
Current consumption from electrochemical sources mA
Permanent
from 0.006 A to 15 A
At 1.1
-
-
0,075 V, 0.3 V, 15 V
6 V to 600 V
-
-
304 uA
1522 uA
-
-
100 ohms
10k
100 kOhm
1000 ohms
-
-
-
-
-
-
-
-
30 mA
6 mA
0.6 mA
0.6 mA
Variable (normal range of frequencies)
from 0.006 A to 15 A
0.3
1.5
6 V to 600 V
At 1.1
-
-
-
-
5000 uA
1025 uA
1540 uA
-
-
-
-

    Frequency range of the tester indicated in Table 2.
 
    Table 2
Ranges
Frequency range, Hz
normal
Working
from 0.06 A to 15 A
from 0.3 V to 30 V
150 V to 300 V
600
45 Hz to 60 Hz
from 60 Hz to 10,000 Hz
from 60 Hz to 10,000 Hz
from 60 Hz to 2000 Hz
from 60 Hz to 1000 Hz
 
    Time for reading devices - no more than 4 seconds.
    Dimensions - 290h200h135 mm.
    Weight of the device combined - 3.5 kg.
    Operating Conditions instruments testers TS4380:
 
    The ambient air temperature - from -30 ° C to +40 ° C.
    Relative humidity at +25 ° C - 90%.
    Atmospheric pressure - from 86 kPa to 106 kPa (650 mm Hg. Art. 800 mm Hg. Tbsp.)
 
    The lower value of the ambient temperature during operation and the protection circuit device using TS4380 power ohmmeter as -20 ° C or -10 ° C and the temperature range is determined by the electrochemical current sources used.

Photos: Ts4380

Ts4380 device image.
Ts4380 device image.
Ts4380 view panel of the device.
Ts4380 view panel of the device.
Ts4380 device image.
Ts4380 device image.
Ts4380 front view.
Ts4380 front view.
Ts4380 side view.
Ts4380 side view.
Ts4380 rear view.
Ts4380 rear view.
Ts4380 overhead view.
Ts4380 overhead view.
Ts4380 bottom view.
Ts4380 bottom view.


Яндекс цитирования