   Combined multifunctional device TS43101

    Also, this device can be called: Ts-43101, Ts 43101.
 
    Ts43101 combined multifunctional device used to measure electricity measuring in electrical circuits measurement objects for which the interaction with the device does not violate a usable state.
    Values ​​that measure testers Ts43101: power and DC voltage, rms power and AC voltage, DC resistance, electric capacity, the absolute level of the signal voltage AC.
 
    Specifications tester:

    Parameters dc current measurements:
 
Range
0-0.05 mA 0-0.25 mA, 0-1 mA, 0-5 mA, 0-25 mA, 0-100 mA, 0-500 mA, 0-2500 mA mA 0-10000.
0-0.1 mA, 0-0.5 mA, 0-2 mA, 0-10 mA, 0-50 mA, 0-200 mA mA 0-1000, 0-5000 mA.
Accuracy class
1.5
1.5
Main error
± 1,5%
± 1,5%
Voltage drop
0.3 V and 0.6 V.
0.6 V.
 
Measurement parameters of AC current:
 
Range
0-0.05 mA 0-0.25 mA, 0-1 mA, 0-5 mA, 0-25 mA, 0-100 mA, 0-500 mA, 0-2500 mA mA 0-10000.
0-0.1 mA, 0-0.5 mA, 0-2 mA, 0-10 mA, 0-50 mA, 0-200 mA mA 0-1000, 0-5000 mA.
Accuracy class
2.5
2.5
The basic error,%
± 2,5%
± 2,5%
Voltage drop in
0.3 V and 0.6 V.
0.6 V.
Current consumption from the power supply, mA
-
1.5 mA.
 
    Measurement parameters DC voltage:
 
Range
In 0-0,075, 0-0.5 V, 0-2.5 V, 0-10, 0-25 V; B 0-100, 0-250 V; 0-500 W.
0-0.15 B, 0-1, 0-5, 0-20 V, 0-50 V; B 0-200, 0-500 V; 0-1000 V.
Accuracy class
1.5
1.5
The basic error,%
± 1,5%
± 1,5%
Voltage drop in
-
-
Current consumption from the measured signal, mA
0.051 mA.
0,102 mA.
Current consumption from the power supply, mA
-
-
 
    Measurement parameters AC voltage:
 
Range
In 0-0,075, 0-0.5 V, 0-2.5 V, 0-10, 0-25 V; B 0-100, 0-250 V; 0-500 W.
0-0.15 B, 0-1, 0-5, 0-20 V, 0-50 V; B 0-200, 0-500 V; 0-1000 V.
Accuracy class
2.5
2.5
The basic error,%
± 2,5%
± 2,5%
Voltage drop in
-
-
Current consumption from the measured signal, mA
0.53 mA.
0.106 mA.
Current consumption from the power supply, mA
1.5 mA.
1.5 mA.
 
    Resistance measurement parameters:
 
Range
0-0.2 ohms, 0-10 ohms, 0-100 ohms, 0-1000 ohms; 0-10000 k.
Accuracy class
2.5
The basic error,%
± 2,5%
Voltage drop in
-
Current consumption from the measured signal, mA
-
Current consumption from the power supply, mA
10.0 mA, 6.0 mA, 1.5 mA.
 
    Measured values ​​of the absolute level of the signal:
 
Range
from -10 dB to +10 dB
Accuracy class
2.5
The basic error,%
± 2,5%
Voltage drop in
-
Current consumption of the input signal, mA
0,053 mA
Current consumption from the power supply, mA
1.5 mA

    Capacitance measurement parameters:
    - Range - 0 to 1000 nF;
    - Accuracy class - 2.5.
    Overall dimensions of the combined Ts43101 - 215x115x87 mm.
    Unit weight - 0.95 kg.
 
    Operating conditions:

    The ambient air temperature - from -10 ° C to +40 ° C.
    Relative humidity at +25 ° C - 80%.
    Pressure - 630 mmHg. Art. to 800 mm Hg. Art.
    Devices combined Ts43101 used for regulation, repair and maintenance of electrical and radio equipment. Prospect and drills with automatic overload protection.