TS1730 TS1730 Ammeter TS1730, voltmeter TS1730
4.9 63

Ammeter TS1730, TS1730 voltmeter (TS-1730, TS 1730)

Designed to measure current and voltage in alternating current frequency of 50, 60 and 400 Hz, as well as signaling the release of the measured value of the specified field values.
Range:
Through the current transformer primary current equal to the final value of the measuring range, and the secondary current 5A: 5A, 10A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A, 1 kA, 1000 A, 1.5 kA, 1500 A; 2ka, 2000A, 3 kA, 3000 A; 4ka, 4000A; 5kA, 5000A, 6 kA, 6000 A; 8kA, 8000A, 10kA, 10000A
Through the current transformer primary current equal to the final value of the measuring range, and the secondary current of 5 A and a current transformer 5 with a length more than 25m Trunk: 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A, 1 kA, 1000 A; 1.5 kA, 1500 A; 2ka, 2000A, 3 kA, 3000 A; 4ka, 4000A; 5kA, 5000A, 6 kA, 6000 A; 8kA, 8000A, 10kA, 10000A
Direct: 30V; 50V 150V, 250V, 450V
With voltage transformer 380/127: 450V
Electrical measuring instruments
analog panel meters
ammeters and voltmeters
alternating current low-frequency (less 1000Hz)

Price:

on request

 

In stock:   more than 100 pieces of all denominations.

Product information updated 12 March 2024.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

Product information updated 12 March 2024.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

Technical characteristics

TS1730 ammeter, voltmeter TS1730 (TS-1730, TS 1730)
Designed to measure current and voltage in alternating current of 50, 60 and 400 Hz, and for marking the release of the measured value of the field specified values.
Measuring range:
Through current transformer primary current equal to the final value of the measuring range, and the secondary current 5A: 5A, 10A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A; 1kA, 1000A , 1.5 kA, 1500A, 2ka, 2000a; 3kA, 3000A; 4ka, 4000A; 5kA, 5000A; 6kA, 6000A; 8kA, 8000A, 10kA, 10000A
Through current transformer primary current equal to the final value of the measuring range, and the secondary current of 5 A and a current transformer at a length of five trunk over 25m: 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A; 1kA, 1000A; 1.5 kA, 1500A, 2ka, 2000a; 3kA, 3000A; 4ka, 4000A; 5kA, 5000A; 6kA, 6000A; 8kA, 8000A, 10kA, 10000A
Direct: 30V; 50V, 150V, 250V, 450V
Voltage transformer 380/127: 450V
TS1730 ammeter, voltmeter TS1730 panel narrow-profile high-impact, vibration and vibration with light indicator rectifier systems are designed to measure current and voltage in alternating current of 50, 60 and 400 Hz, and for marking the release of the measured value of the field specified values. TS1730 devices can work together with the regulating device, which is compatible with the input parameters of signal circuits.
TS1730 ammeter, voltmeter TS1730 are designed to operate at ambient temperatures from minus 30 to plus 50 ° C and relative humidity up to 100% at 50 ° C.
Devices in the tropical version operating at an ambient temperature of -10 to 55 ° C and relative humidity up to 100% (at 35 ° C) and are designated TS1730AT2, TS1730ST2, TS1730KT2.
Designation TS1730 and add-on devices are given in Table 1.
 
Table 1
Product designation Features design Note
TS1730A, TS1730A T, T2 TS1730A - -
TS1730S, TS1730S T, T2 TS1730S Device with help signal filters -
TS1730K, TS1730K T, T2 TS1730K Device with help signal filters and photoresistors (three-pin) Vihode signals measured value of the given values ​​of the right and left (the gauges)
TS1730KP, TS1730KP T, T2 TS1730KP Device with help signal filters and photoresistors (pin DIP) Output signals from the measured value of the given values ​​to the right (the gauges)
TS1730KL, TS1730KL T, T2 TS1730KL - Output signals from the measured value of the given values ​​to the left (the gauges)
R1820 / 6 - Additional device to the ammeter
R1820 / 7 - Additional device to a voltmeter
Technical data
 
The final values ​​of the measuring range of devices ammeter and voltmeter TS1730 and how they connect to the network are given in Table 2. Self-consumption devices: Ammeter - no more than 5 VA, voltmeter - no more than 10V A. Maximum permissible error of the instrument ammeter and voltmeter TS1730 in the measurement range is ± 1,5% of full scale range.
 
Table 2
The final values ​​of the measuring range A way to connect the device
Ammeters
5A, 10A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A
1kA, 1.5 kA 2ka; 3kA; 4ka; 5kA; 6kA; 8kA, 10 kA
Through current transformer primary current equal to the final value of the measuring range, and the secondary current 5 A
100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A;
1kA, 1.5 kA 2ka; 3kA; 4ka; 5kA; 6kA; 8kA, 10kA
Through current transformer primary current equal to the final value of the measuring range, and the secondary current of 5 A and a current transformer 5 with a trunk length of 25 m
Voltmeters
30V, 50V, 150V, 250V, 450V Direct
450V Voltage transformer 380/127

The lower limit of the measuring range should not exceed 15% of the final value of the measuring range. Maximum permissible error tripping contact device to device modifications, CP and CL is ± 2,0% of full scale range.
Burst tolerance for contact devices receive the difference between the actual value of the measured value at the time of operation and the amount by which the index is set contact device (edge ​​filter).
Output current   contact device in the devices modifications K, CP and CL - 30 mA (max) in the dark state, and 250 mA (at least) - the lit state for their nutrition from a source voltage of 12 V. The light source used incandescent 0P6-3 -B5 with focusing cap.
Dining illuminator device ammeter and voltmeter TS1730 is the transformer P1710 (10 lamps), P1711 (20 lamps), P1712 (50 bulbs) or from any source of AC or DC voltage of 6 V. The deviation from the nominal voltage within from plus 10 to minus 1%.
Scope of the position indication filters and indexes contact device are shown in Table 3.
 
Table 3
Modification devices The scope of the index,% (of scale length)
Left right
TS1730S, TS1730S T, T2 TS1730S 0-90 20-90
TS1730K, TS1730K T, T2 TS1730K 0-85 20-90
TS1730KP, TS1730KP T, T2 TS1730KP - 10-95
TS1730KL, TS1730KL T, T2 TS1730KL 0-90 -

Scale length indicating instrument at least 118 mm. The limit of additional error caused by: a deviation from the ambient temperature plus (20 ± 5) ° C to any temperature within the range of minus 30 to plus 50 ° C at a humidity of 80%, is for every 10 ° C change:
voltmeters to ± 0,8%;
ammeters to ± 0,5%;
influence of an external uniform magnetic field with induction of 0.5 mT is ± 1%;
changing position of the device from its normal position in any direction is equal to 45 0 to ± 1%.
Additional error is expressed as a percentage of the final value of the measuring range.
Response time is less than 3 seconds. Dielectric strength 2kV. Insulation resistance at temperature (25 ± 10) ° C and relative humidity up to 80% - 50 MW.
Overall dimensions: indicating instrument - 160x30x272, 5; additional device R1820 / 6 (R1820/7) - 111x158x95.
Weight, kg, no more than indicating instrument - 1.5 additional devices - 1.5.
Rate the product: TS1730
Number of views: 1132
Product rating: 4.4
Number of grades: 301
* rating and all product statistics are updated once a month; information is current as of 27 March 2024

Photos TS1730

TS1730 device image with the addition R1820/6T (P1820/6T).

TS1730 device image with the addition R1820/6T (P1820/6T).

TS1730 side view (casing depth).

TS1730 side view (casing depth).

TS1730 side view (casing depth).

TS1730 side view (casing depth).

TS1730 rear view (connection).

TS1730 rear view (connection).

TS1730 side view (casing depth).

TS1730 side view (casing depth).

R1820/6T (P1820/6T) additional device front view.

R1820/6T (P1820/6T) additional device front view.

R1820/6T (P1820/6T) additional device side view.

R1820/6T (P1820/6T) additional device side view.

R1820/6T (P1820/6T) additional device overhead view.

R1820/6T (P1820/6T) additional device overhead view.

Leading online store Zapadpribor - a huge selection of measuring equipment for the best value and quality. So you can buy inexpensive devices, we monitor competitors' prices and are always ready to offer a lower price. We only sell quality products at the best prices. On our site you can buy cheaply as the latest innovations and proven equipment from the best manufacturers.

The site includes a special offer «buy at the best price» - if other Internet resources (bulletin board, forum or announcement of another online service) in products presented on our site, the lower price, we will sell it to you even cheaper! Buyers also additional discount for leaving a review or photo of use of our products.

In the price list contains not the whole range of products offered. Prices of goods, not included in the price list can learn to contact the manager. Also, our managers You can get detailed information about how cheap and profitable to buy instrumentation wholesale and retail. Telephone and e-mail for advice on the purchase , delivery or receipt are shown on the description of the goods. We have the most qualified staff, quality equipment and the best price.

 

Online store Zapadpribor - the official manufacturer's dealer test equipment. Our goal - selling high quality goods with best price offer and service to our customers. Our store can not only sell you the necessary instrument, but also offer additional services to its calibration, repair and installation. That you have a pleasant experience when shopping on our site, we have provided special gifts guaranteed to the most popular products.

 

We offer fast international shipping to almost every country in the world: Australia, Austria, Azerbaijan, Albania, Algeria, Anguilla, Angola, Antigua and Barbuda, Argentina, Aruba,  Bahamas, Bangladesh, Barbados, Bahrain, Belize, Belgium, Benin, Bermuda, Bulgaria, Bolivia, Bonaire, Sint-E. and Saba, Bosnia and Herzegovina, Botswana, Brazil, British Virgin Islands, Brunei Darussalam, Burkina Faso, Burundi, Bhutan, VietNam, Vanuatu, Vatican City, Venezuela, Armenia, Gabon, Guyana, Haiti, Gamia, Gambia, Ghana, Guatemala, Guinea, Gibraltar, Honduras, Hong Kong, Grenada, Greenland, Greece, Georgia, Denmark, Democratic Republic of the Congo, Jersey, Djibouti, Dominica, Dominican Republic, Ecuador, Eswatine, Estonia, Ethiopia, Egypt, Zambia, Zimbabwe, Jordan Indonesia, Ireland, Iceland, Spain, Italy, Cape Verde, Kazakhstan, Cayman Islands, Cambodia, Cameroon, Canada, Qatar, Kenya, Kyrgyzstan, China, Cyprus, Kiribati, Colombia, Comoros, Congo, Korea (Rep.), Costa Rica, Kot-d'Ivoire, Cuba, Kuwait, Curacao, Laos, Latvia, Lesotho, Lithuania, Liberia, Lebanon, Libya, Liechtenstein, Luxembourg, Myanmar, Mauritius, Mauritania, Madagascar, Macao, Malawi, Malaysia, Mali, Maldives, Malta, Morocco, Mexico, Mozambique, Moldova, Monaco, Monaco, Namibia, Nauru, Nepal, Niger, Nigeria, Netherlands, Germany, New Zealand, New Caledonia, Norway, UAE, Oman, Cook Islands, Pakistan, Palestine, Panama, Papua New Guinea, Paraguay, Peru, South Africa, Poland, Portugal, Republic of Chad, Rwanda, Romania, El Salvador, Samoa, San Marino, Saudi Arabia, Swaziland, Seychelles, Senegal, Saint Vincent and the Grenadines, Saint Kitts and Nevis, Saint Lucia, Serbia, Singapore, Sint Maarten, Slovakia, Slovenia, Solomon Islands, United Kingdom of Great Britain and Northern Ireland, Sudan, Suriname, East Timor (Timor-Leste), USA, Sierra Leone, Tajikistan, Taiwan, Thailand, Tanzania (United Republic of), Togo, Tonga, Trinidad and Tobago, Tuvalu, Tunisia, Turkey, Turkmenistan, Uganda, Hungary, Uzbekistan, Uruguay, Faroe Islands, Fiji, Philippines, Finland, France, French Polynesia, Croatia, Central African Republic, Czech Republic, Chile, Montenegro, Switzerland, Sweden, Sri Lanka, Jamaica, Japan.

We also provide such metrological procedure: calibration, tare, graduated, testing of measuring instruments.

The online store takes an active part in such procedures as electronic bidding, tender, auction.

If there is no site in the descriptive information you need on the device you can always turn to us for help. Our qualified managers will update for you on the technical characteristics of the device from its technical documentation: user manual, certificate, form, operating instructions, diagram. If necessary, we will take a photo of your device, or a device stand. You can leave feedback on the unit purchased from us, the meter, the device, indicator, or product. Your review for your approval will be published on the site without contact information.

 

Description of the instruments taken from the technical documentation or technical literature. Most pictures of products made directly by our experts prior to shipment of goods. In the description of the device provided the main technical characteristics of the instrument: nominal measuring range, accuracy class, scale, supply voltage, size (size), weight. If the site you see the discrepancy device name (model) specifications, photo or documents attached - let us know - you will get a useful gift with-selling device.

 

While the need to clarify the overall weight and size or the size of the individual meter you can in our service center. If you need our engineers will help you choose the most complete analog or a suitable replacement for the device you are interested. All counterparts and replacement will be tested in one of our laboratories with the full compliance to your requirements.

In the technical documentation for each device or product, information is provided on the list and amount of precious metals content. The documentation gives the exact weight in grams of precious metals: Au gold, palladium Pd, platinum Pt, silver Ag, tantalum Ta and other platinum group metals (PGM) per unit item. These precious metals are found in nature in very limited quantities and therefore have such a high price.

On our website you can familiarize yourself with the technical characteristics of devices and obtain information on the content of precious metals in devices and radio components manufactured in the USSR. We draw your attention to the fact that often the actual content of precious metals differs by 10-25% from the reference one in a smaller direction! The price of precious metals will depend on their value and mass in grams.

All text and graphic information on the site is informative. The color, shade, material, geometric dimensions, weight, content, delivery set and other parameters of the goods presented on the site may vary depending on the batch of production and year of manufacture. Check with the sales department for more information.

 

If you can make repairs to the device yourself, our engineers can provide you with a complete set of necessary technical documentation: circuit diagram TO, ER, FD, PS. We also have an extensive database of technical and metrological documents: technical specifications (TS), the terms of reference (TOR), GOST (DSTU), the industry standard (OST) test procedure, the method of certification, verification scheme for more than 3,500 types of measuring equipment from the manufacturer this equipment. From the site you can download all the necessary software (the software driver) is required for the product purchased.

We carries out repairs and maintenance of measuring equipment in more than 75 different factories of the former Soviet Union and CIS.

We also have a library of legal documents that are related to our field of activity: the law, code, ordinance, decree, temporary position.