Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> alternating current low-frequency (less 1000Hz) >> narrow realm alternating current

TS1730

available:
100 pieces
For order is possible effectively delivery of any quantity.
TS1730 ammeter, voltmeter TS1730 (TS-1730, TS 1730)
Designed to measure current and voltage in alternating current of 50, 60 and 400 Hz, and for marking the release of the measured value of the field specified values.
Measuring range:
Through current transformer primary current equal to the final value of the measuring range, and the secondary current 5A: 5A, 10A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A; 1kA, 1000A , 1.5 kA, 1500A, 2ka, 2000a; 3kA, 3000A; 4ka, 4000A; 5kA, 5000A; 6kA, 6000A; 8kA, 8000A, 10kA, 10000A
Through current transformer primary current equal to the final value of the measuring range, and the secondary current of 5 A and a current transformer at a length of five trunk over 25m: 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A; 1kA, 1000A; 1.5 kA, 1500A, 2ka, 2000a; 3kA, 3000A; 4ka, 4000A; 5kA, 5000A; 6kA, 6000A; 8kA, 8000A, 10kA, 10000A
Direct: 30V; 50V, 150V, 250V, 450V
Voltage transformer 380/127: 450V
TS1730 ammeter, voltmeter TS1730 panel narrow-profile high-impact, vibration and vibration with light indicator rectifier systems are designed to measure current and voltage in alternating current of 50, 60 and 400 Hz, and for marking the release of the measured value of the field specified values. TS1730 devices can work together with the regulating device, which is compatible with the input parameters of signal circuits.
TS1730 ammeter, voltmeter TS1730 are designed to operate at ambient temperatures from minus 30 to plus 50 ° C and relative humidity up to 100% at 50 ° C.
Devices in the tropical version operating at an ambient temperature of -10 to 55 ° C and relative humidity up to 100% (at 35 ° C) and are designated TS1730AT2, TS1730ST2, TS1730KT2.
Designation TS1730 and add-on devices are given in Table 1.
 
Table 1
Product designation Features design Note
TS1730A, TS1730A T, T2 TS1730A - -
TS1730S, TS1730S T, T2 TS1730S Device with help signal filters -
TS1730K, TS1730K T, T2 TS1730K Device with help signal filters and photoresistors (three-pin) Vihode signals measured value of the given values ​​of the right and left (the gauges)
TS1730KP, TS1730KP T, T2 TS1730KP Device with help signal filters and photoresistors (pin DIP) Output signals from the measured value of the given values ​​to the right (the gauges)
TS1730KL, TS1730KL T, T2 TS1730KL - Output signals from the measured value of the given values ​​to the left (the gauges)
R1820 / 6 - Additional device to the ammeter
R1820 / 7 - Additional device to a voltmeter
Technical data
 
The final values ​​of the measuring range of devices ammeter and voltmeter TS1730 and how they connect to the network are given in Table 2. Self-consumption devices: Ammeter - no more than 5 VA, voltmeter - no more than 10V A. Maximum permissible error of the instrument ammeter and voltmeter TS1730 in the measurement range is ± 1,5% of full scale range.
 
Table 2
The final values ​​of the measuring range A way to connect the device
Ammeters
5A, 10A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A
1kA, 1.5 kA 2ka; 3kA; 4ka; 5kA; 6kA; 8kA, 10 kA
Through current transformer primary current equal to the final value of the measuring range, and the secondary current 5 A
100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A;
1kA, 1.5 kA 2ka; 3kA; 4ka; 5kA; 6kA; 8kA, 10kA
Through current transformer primary current equal to the final value of the measuring range, and the secondary current of 5 A and a current transformer 5 with a trunk length of 25 m
Voltmeters
30V, 50V, 150V, 250V, 450V Direct
450V Voltage transformer 380/127

The lower limit of the measuring range should not exceed 15% of the final value of the measuring range. Maximum permissible error tripping contact device to device modifications, CP and CL is ± 2,0% of full scale range.
Burst tolerance for contact devices receive the difference between the actual value of the measured value at the time of operation and the amount by which the index is set contact device (edge ​​filter).
Output current   contact device in the devices modifications K, CP and CL - 30 mA (max) in the dark state, and 250 mA (at least) - the lit state for their nutrition from a source voltage of 12 V. The light source used incandescent 0P6-3 -B5 with focusing cap.
Dining illuminator device ammeter and voltmeter TS1730 is the transformer P1710 (10 lamps), P1711 (20 lamps), P1712 (50 bulbs) or from any source of AC or DC voltage of 6 V. The deviation from the nominal voltage within from plus 10 to minus 1%.
Scope of the position indication filters and indexes contact device are shown in Table 3.
 
Table 3
Modification devices The scope of the index,% (of scale length)
Left right
TS1730S, TS1730S T, T2 TS1730S 0-90 20-90
TS1730K, TS1730K T, T2 TS1730K 0-85 20-90
TS1730KP, TS1730KP T, T2 TS1730KP - 10-95
TS1730KL, TS1730KL T, T2 TS1730KL 0-90 -

Scale length indicating instrument at least 118 mm. The limit of additional error caused by: a deviation from the ambient temperature plus (20 ± 5) ° C to any temperature within the range of minus 30 to plus 50 ° C at a humidity of 80%, is for every 10 ° C change:
voltmeters to ± 0,8%;
ammeters to ± 0,5%;
influence of an external uniform magnetic field with induction of 0.5 mT is ± 1%;
changing position of the device from its normal position in any direction is equal to 45 0 to ± 1%.
Additional error is expressed as a percentage of the final value of the measuring range.
Response time is less than 3 seconds. Dielectric strength 2kV. Insulation resistance at temperature (25 ± 10) ° C and relative humidity up to 80% - 50 MW.
Overall dimensions: indicating instrument - 160x30x272, 5; additional device R1820 / 6 (R1820/7) - 111x158x95.
Weight, kg, no more than indicating instrument - 1.5 additional devices - 1.5.

Photos TS1730

TS1730 device image with the addition R1820/6T (P1820/6T).
TS1730 device image with the addition R1820/6T (P1820/6T).
TS1730 side view (casing depth).
TS1730 side view (casing depth).
TS1730 side view (casing depth).
TS1730 side view (casing depth).
TS1730 rear view (connection).
TS1730 rear view (connection).
TS1730 side view (casing depth).
TS1730 side view (casing depth).
R1820/6T (P1820/6T) additional device front view.
R1820/6T (P1820/6T) additional device front view.
R1820/6T (P1820/6T) additional device side view.
R1820/6T (P1820/6T) additional device side view.
R1820/6T (P1820/6T) additional device overhead view.
R1820/6T (P1820/6T) additional device overhead view.


Яндекс цитирования