Datasheets and radio parts >> connectors radio-frequency >> SR-50 (cp-50) >> SR-50-...FV

SR-50-63FV

455 RUB
107 UAH
available:
179 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Made in: 2016.

 

    Fork cable SR-50-63FV (SR50-63FV; 63FV CP-50).

    Fork SR 50 63FV intended to connect two terminals of the same or different connection dimensions when their direct mechanical connection is not feasible or undesirable direct electrical connection.
    Connector Type - Male.
    Sequence number of development - 63.
    Insulator material - Teflon.
    Connection Type - bayonet.
    Characteristic impedance - 50Om.
    Operating voltage - 500V.
    Frequency range - from 0 to 10 GHz.
    The type designation SR-50-63FV:

    - SR - RF connector;
    - 50 - the value of the characteristic impedance (ohms);
    - 63 - number of development;
    - F - insulation (PTFE);
    - In the - all-climate performance by GOST In 20.39.404-81.
    SR-50-63FV - leaky straight connector with Teflon insulation. Product is a combination of two coaxial connectors, connected by short rigid coaxial line segment.
    Connector Dimensions - 22 × 46,5 mm.

    Drawing socket is shown in Figure 1.
 
SR-50-63FV cable plug drawing

    Figure 1. Drawing outlet SR-50-63FV.
    Specifications SR-50-63FV:

    - Contact materials - brass, plated with silver.
    - Maximum operating frequency - 10000MGts.
    - Operating voltage under normal conditions 500V (peak);
    - Impedance - 50Om;
    - Contact resistance - 0.01 ohms.
 
    Plugs SR 63FV 50 have the following values ​​of insulation resistance between the connector elements:
    - Under normal circumstances - 1000MOm;
    - At a temperature of 85 º C to 200 º C - 500MOm;
    - At 98% humidity and a temperature of 40 º C - 100MOm.

    The test voltage for plugs SR-50-63FV:
    - Normal 750V (Vp);
    - At atmospheric pressure 5mm.rt.st. - 250V (Vp);
    - At 98% humidity and a temperature of 40 º C - 500 V (Vp).
    Voltage standing wave ratio of the compounds plugs CP-50-63FV with other terminals on the 3000MHz frequency range from 1.25 to 1.6 VSWR VSWR, depending on the combinations of joints.

    For connector SR-50-63FV nominal operating voltage has the following values:
    - Normal - 250-350B (Vp) depending on the embodiment of the compound;
    - Atmospheric pressure 5mm.rt.st. - 50V (Vp);
    - Humidity of 98% (at a temperature of 40 º C) - 250V - 350V (Vp) depending on the connection options.
    MTTF connector SR-50-63FV under different conditions of temperature filed in Table 1.

    Table 1.
Degrees, ° C
Hours of use
95 ° C
500h
85 ° C
1000h
74 ° C
2000h
68 ° C
3000h
60 ° C
5000h
54 ° C
8000 h
50 ° C
10000h
40 ° C
20000h
32 ° C
30000h
25 ° C
50000h
18 ° C
80000h
14 ° C
10000h
    Cycle of mechanical operation, which on average can withstand fork - 500. To break up the contacts you need to make an effort of 0.5 kgf-2kgs. Reliability forks: the minimum probability of failure of connector P 2 = 0.99 for 1000 hours at the reliability of R 36 = 0.9.
    Lifetime SR-50-63FV - 5000 hours.

    Operating conditions connector SR-50-63FV:
 
    Operating temperature range - from -60 ° C to +155 ° C. Relative humidity - 98% at 40 ° C. Low atmospheric pressure - up to 5 mm Hg.
    Vibration strength and stability of devices ranges in the frequency range 5 Hz - 5000Hz with an acceleration of 30g.
    SR-50-63FV able to withstand:
    - Single mechanical shocks with acceleration up to 500g;
    - Multiple mechanical shocks with acceleration up to 150g;
    - Linear loads up to 500g.
    Connector griboustoychivy, resistant to sea fog, solar radiation.

    Storage conditions of SR-50-63FV
 
    Minimal storage time slots - 20 years. Can be stored in warehouse conditions in their original packaging at room temperature 5 º C-35 º C at a relative humidity of 85% - up to 11 years.
    During this period be stored SR 50 63FV in the apparatus and the ISP in the field at an ambient temperature of -50 º C and +50 º C, a relative humidity of 98%, while protecting them from direct exposure to the sun radiation and rainfall for 3 or, under the same conditions as when finding them in a sealed moisture-proof equipment or for 5 years.