Selsyns, rotary transformers, electric motors >> transformers rotating >> SKT

SKT-232P Transformer CTS-232P rotating pole frameless.

SKT-232P

For order is possible effectively delivery of any quantity.
Transformer SKT-232P open-frame rotating pole (SKT232P, SKT-232-P, SKT 232 P, SKT 232P, SKT232-P, SKT232 P)
 
Rotary transformers SKT-232P is a four stretch wrapping machines.
Depending on the scheme and the inclusion mode (function) open-frame devices rotating transformer pole SKT-232P divided into sine-cosine (Synchro), output voltage which is proportional to the sine (cosine) the angle of rotation of the rotor, and linear (LVT), the output voltage which varies linearly proportional to the angle of ± 60 °.
 
Technical characteristics of the instrument transformers SKT-232P Rotary frameless bipolar:
 
Purpose - VTDP-P;
The change of ratio when the ambient temperature at every 40 ° C - 3%;
Nominal frequency of the excitation voltage instrument transformer SKT-232P open-frame rotating pole - 400Hz;
Operating frequency range of excitation voltage - 380Gts-420Gts;
Nominal excitation voltage - 36V;
Operating range of excitation of the instrument transformer SKT-232P open-frame rotating pole - 32.4 B-37, 8V;
Input impedance idling - 750 ohms;
Turns Ratio - 0.58;
Rotary transformers SKT-232P are divided into accuracy classes:
- Transformer SKT-232P an accuracy class (1st class. Etc.) has the characteristics:
- Error display the sine function - ± 0,1%;
- Asymmetry of the null positions of the rotor - ± 2,5 ang;
- The ratio of residual to the steepness of the EMF - ± 5,0 ang;
- The inequality of the coefficients of transformation - 2.5 ang;
- Indicators of the accuracy TPD composed of Tues-232D SKT, SKT-232P:
- Accuracy class transmitter and receiver - 0.1;
- Accuracy of following TPD - ± 5ugl.min;
- The ratio of residual to the steepness of the EMF - 7ugl.min;
- Slope - 2mV/ugl.min;
- Indicators of the accuracy TPD composed of Tues SKT-232D8, SKT-232P:
- Accuracy class transmitter and receiver - 0.1;
- Accuracy of following TPD - ± 5ugl.min;
- The ratio of residual to the steepness of the EMF - 7ugl.min;
- The slope of - 0.8 mV / ang;
- Transformer SKT-232P Class 2 accuracy (2 cl. T) has the characteristics:
- Error display the sine function - ± 0,2%;
- Asymmetry of the null positions of the rotor - ± 5,0 ang;
- The ratio of residual to the steepness of the EMF - 7.5 ang;
- The inequality of the coefficients of transformation - 5.0 ang;
- Indicators of the accuracy TPD composed of Tues-232D SKT, SKT-232P:
- Accuracy class transmitter and receiver - 0.2;
- Accuracy of following TPD - ± 10ugl.min;
- The ratio of residual to the steepness of the EMF - 10ugl.min;
- Slope - 2mV/ugl.min;
- Indicators of the accuracy TPD composed of Tues SKT-232D8, SKT-232P:
- Accuracy class transmitter and receiver - 0.2;
- Accuracy of following TPD - ± 10ugl.min;
- The ratio of residual to the steepness of the EMF - 10ugl.min;
- The slope of - 0.8 mV / ang;
- Transformer SKT-232P Class 3 accuracy (3 cl. T) has the characteristics:
- Error display the sine function - ± 0,35%;
- Asymmetry of the null positions of the rotor - ± 10ugl.min;
- The ratio of residual to the steepness of the EMF - 10ugl.min;
- The inequality of the coefficients of transformation - 10ugl.min;
- Indicators of the accuracy TPD composed of Tues-232D SKT, SKT-232P:
- Accuracy class transmitter and receiver - 0.35;
- Accuracy of following TPD - ± 20ugl.min;
- The ratio of residual to the steepness of the EMF - 15ugl.min;
- Slope - 2mV/ugl.min;
- Indicators of the accuracy TPD composed of Tues SKT-232D8, SKT-232P:
- Accuracy class transmitter and receiver - 0.35;
- Accuracy of following TPD - ± 20ugl.min;
- The ratio of residual to the steepness of the EMF - 15ugl.min;
- The slope of - 0.8 mV / ang;
Dimensions instrument transformer SKT-232P pole revolving, open-frame:
- Length - 32mm;
- Diameter - 12mm;
Weight - 0.0045 kg;
Vibration loads instrument transformer SKT-232P pole revolving, open-frame:
- Frequency range - up to 300 Hz;
- Acceleration - 100m / s 2;
Shock - 120m / s 2;
Ambient temperature - -60 ° C to +100 º C;
Relative humidity at 40 ° C - 98%;
Warranty life instrument SKT-232P open-frame transformer rotating pole - 3000 hours;
The manufacturer guarantees the quality of the instrument transformer SKT-232P revolving, open-frame pole technical requirements specifications subject to user terms and conditions of storage, transportation, installation, operation, established specifications and operational documentation. 


Яндекс цитирования