shunt 75SHP

2 406 RUB
1 203 UAH
available:
110 pieces

Online prices include VAT.

It is possible effectively delivery of any quantity.
Shunt 75SHP 75-SHP, 75 SHP)
 
75SHP shunt is designed to expand the limits of the measurement and recording devices featuring DC.
 
Technical characteristics of the instrument shunts 75SHP:
 
Designed to expand the limits of the measurement and recording devices featuring DC.
Rated current shunt devices 75SHP: 5A, 10A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 500A, etc.
Accuracy class - 0.2;
Nominal voltage drop at any limit of measurement - 75mV;
Shunt 75SHP 0,3-0,75 has:
- The limit of measurement - 0.3 A-0, 75A;
- Nominal impedance - 0.25640 ohm-0, 10 260 ohms;
- A lot - 0,190;
- Cross cable - 1.0 mm 2;
Shunt 75SHP 1,5-7,5 has:
- The limit of measurement - 1.5 A-7, 5A;
- Nominal impedance - 0.05025 ohm-0, 01 005 ohms;
- Weight - 0,200 kg;
- Cross cable - 1.5 mm 2;
Shunt 75SHP 15-30 is:
- The limit of measurement - 15A-30A;
- Nominal impedance - 0.00500 ohm-0, 00 250 ohms;
- Weight - 0.230 kg;
- Cross cable - 6.0 mm 2;
Shunt 75SHP 75 has:
- The limit of measurement - 75A;
- Nominal impedance - 0.00100 ohms;
- Weight - 0.240 kg;
- Cable cross-sections - 20.0 mm 2;
Shunt 75SHP 150 has:
- The limit of measurement - 150 A;
- Nominal impedance - 0.00050 ohms;
- Weight - 0.265 kg;
- Cable cross-sections - 40.0 mm 2;
Limits of variation values ​​of shunt resistance, which appears as a result of thermoelectric power under normal load current is equal to half the maximum permissible basic error;
Acceptable basic error limit product 75SHP shunt caused by ambient temperature deviation from the normal to any temperature within the limits established working conditions of application, ± 0,1% for every 10 º C temperature change;
The insulation between the electrical circuit and a shunt housing must withstand for 1 minute action of the test voltage 2kV nearly sinusoidal and the frequency of 50 Hz;
The insulation resistance between the body and isolated dc electric circuits shunt 75SHP product must be not less than:
- 40 MW - in the normal conditions of use;
- 5 MW - at 50 º C and relative humidity of 80%;
- 2 MW - at an ambient temperature of 20 º C ± 5 º C and relative humidity of 95%;
- 0.5 MW - an ambient temperature of 60 º C and relative humidity of 95%;
Dimensions of the product shunt 75SHP - 120h60h60mm;
The service life to failure - not less than 12 years.