Control and measuring devices >> rotameters

RPO-16ZHUZ Rotameter RPO-16ZHUZ.


For order is possible effectively delivery of any quantity.
Rotameter RPO-16ZHUZ (RPO16ZHUZ, RPO 16 ZHUZ, RPO-16-ZHUZ RPO16 ZHUZ, RPO16 zhuz, RPO 16ZHUZ)
Type flowmeters are designed to measure the RPO volumetric flow smoothly varying uniform flow of clean and low contaminated liquids crystallising with dispersed nonmagnetic inclusions of foreign particles, neutral to become 12H17N13M2T and convert it into a unified pneumatic signal.
Rotameters work included with the secondary pneumatic devices or devices with the outside air pressure of 0.2 kgf / cm 2 to 1.0 kgf / cm 2.
Depending on the flow of the medium, such as rotameters RPO issued by the manufacturer in five basic configurations: RPO-I, RPO-II, RPO-III, RPO-IV.
Each base model has a unified body of rotametricheskoy. Measuring Range spending for these models are obtained by setting the corresponding cone and orifice - the installation of the collar.
Rotameters of type RPO have a single unified pnevmogolovku transforming the flow rate in pneumatic signal and provides local indication.
Local scale readings - the conditional uniform.
Technical characteristics of the devices rotameters RPO-16ZHUZ.
The lower limit of measurement - no more than 20% of the upper limit of measurement.
The material used in the instrument rotameter RPO-16ZHUZin contact with medium - steel 10H17N13M2T.
The temperature of the liquid - from +5 º C to +150 ° C.
Devices rotameter RPO-16ZHUZ designed for operation in ambient temperatures from -5 º C to +50 ° C and relative humidity from 30% to 80%.
The basic permissible error on the scale of local evidence and pnevmosignalu:
- For rotameters with an upper limit of measurement of 0.4 m 3 / h to 63.0 m 3 / h - ± 1,5%; ± 2,5%; ± 4%;
- For rotameters with an upper limit of measurement of 0.1 m 3 / h to 0.25 m 3 / h - ± 2,5%; ± 4%.
Meals rotameter by compressed air pressure of 140kPa ± 14kPa (1.4 kgf / cm 2 ± 0,14 kg / cm 2).The air of class 0, 1, 3.
Change limits the device rotameter RPO-16ZHUZ pressure signal output  - 20kPa to 100kPa of (0.2 kgf / cm 2 -1kgs/sm 2).
The greatest distance flowmeter output signal to a secondary device - 250m.
Calibration of Rotameters - individually made by the manufacturer on the water. In the measurement of fluid flow, which has other than water viscosity and density, it is necessary to recalculate flow at a given liquid.
Material sealing device rotameter RPO-16ZHUZ - paronite.
Joining the flowmeter in the pipeline - flanged.
The upper limit of measurement - 16 m 3 / h.
Conditional pass device rotameter RPO-16ZHUZ - 100mm.
Operating pressure - 16kPa.
The mass flowmeter device RPO-16ZHUZ - 41kg.
Dimensions - 466h220h312mm.