High-frequency signal generator RG4-02

Also, this device can be called: RG402, RG4 02, RG4-O2.

RG4-02 high-frequency signal generators (special purpose) - designed to provide off-line measurements and automated measuring systems.

Frequency - 10 kHz to 50 MHz (± 0,2%).

Scope RG4-02: Radio Engineering in various areas for a wide range of measurement tasks in automated measuring systems, particularly when setting up, testing, repair, calibration of various radio systems and devices, electronic products, both in the laboratory and in the field conditions.

 

Specifications RG4-02:

 

Error of frequency:

- Basic - no more than ± 0,1%;

- In the range of operating temperatures - no more than ± 0,15%.

Frequency instability - no more than ± 5.10 -5.

Electronic frequency tuning (Voltage - 4.5 V to - 4.5 V, 4.5 V, frequency - from 0 Hz to 20 Hz) - not less than 0.01%.

Spurious frequency deviation in the band from 30 Hz to 20 kHz - not more than 1.10 -5.

Characteristic impedance RG4-02 - 50 ohms.

VSWR - no more than 1.6.

 

Output:

- Output A - not less than 2 watts;

- Exit B - not less than 0.3 mW.

The limit of output power at output A - at least 30 dB.

Instability of the output power level - less than ± 0,2 dB.

Harmonic content of the instrument RG4-02 - no more than -25 dB.

Pulse frequency meander - 1000 ± 100 Hz.

 

Rectangular pulses

 

External modulation:

- Frequency range - from 25 MHz to 50 MHz;

- Pulse width - from 0.5 ms to 500 ms;

- Repetition rate - 50 Hz to 20 kHz;

- Rising and falling - not more than 0.1 ms;

- Uneven tops - no more than ± 5%;

- Amplitude - 4 V to 40 V.

 

The output signal (output A) RG4 generator 02 at an external modulation

- Duration of the front - no more than 0.25 ms;

- The duration of the cut - no more than 0.5 ms;

- Uneven tops - no more than 25%;

- Deviation from modeling pulse - no more than ± 0,25 ms.

External trigger comes from the rectangular pulses (duty cycle - at least 2).

 

The output signal (output A) with external triggering:

- Pulse duration - from 1 ms to 20 ms;

- Duration of the front - no more than 0.3 ms;

- The duration of the cut - no more than 0.6 ms;

- Uneven tops - no more than 25%;

- The margin of error pulse - ± (10 + (0,3 Tmin / T) · 100)

where Tmin - guaranteed lowest nominal pulse duration, ms;

T - nominal duration microseconds.

 

RG4 output signal 02 (output A), at an internal modulation

- Frequency range - from 25 MHz to 50 MHz;

- Pulse duration - from 1 ms to 20 ms;

- Repetition rate - 50 Hz to 20 kHz;

- Duration of the front - no more than 0.3 ms;

- The duration of the cut - no more than 0.6 ms;

- Uneven tops - no more than 25%;

- The margin of error:

- Pulse - no more than ± 10%;

- Pulse width - ± (10 + (0,3 Tmin / T) · 100).

 

Synchronization pulse generators RG4-02:

 

- Pulse width - 1 ± 0,5 ms;

- Duration of the front - no more than 0.5 ms;

- The amplitude of the - at least 4;

- Load - not less than 10 ohms;

- Capacity - no more than 50 pF.

The attenuation of the output signal - at least 30 dB.

The electric field strength (distance - 1 m) - no more than 5 10 -3 V / m

Continuous operation of the signal generator RG4-02 - at least 16 hours.

 

Temporal characteristics of the RF generator:

- Setting frequency - no more than 1;

- The establishment of power - less than 1 s;

- Programming time - no more than 20 ms;

- Issuing data format - no more than 30 ms;

- Issue of the status byte - no more than 10 ms.

Mean time to failure of the generator - not less than 5000 hours

Gamma-percent life, when γ - 80% - at least 12,000 hours

Gamma-percent period, when γ - 80%:

- Service - not less than 12 years;

- Persistence - 10 years (heated storage), 5 years (unheated warehouse).

Interface - CPC.

Weight - 25 kg.

Dimensions - 488x555x132 mm.

 

Operating conditions RG4-02:

 

Ambient temperature for robots - from -10 º C to +50 º C (263 K to 323 K).

Relative humidity at +25 º C - 98%.

AC voltage - 220 ± 22, 220 ± 11; 115 ± 5,75 V.

The frequency of the AC - 50 ± 0,5 Hz from 388 Hz to 428 Hz.

The harmonic content of a 400 Hz - not more than 5%.

Power consumption for the device generator RG4-02 - no more than 250 V·A.