Bridge AC R577 (R-577, R 577)
 
Bridge AC R577 is designed to measure the ac frequency from 40Hz to 20,000 Hz capacitance, inductance, resistance, AC and DC power.
 
Technical characteristics of the devices ac bridges R577:
 
Accuracy class - 1.0;
Frequency of the instrument bridge AC R577 - 40Hz-20000Hz;
The main technical characteristics of the instrument bridge AC R577 are shown in Table 1, Table 2, Table 3;
 
Table 1 Main technical characteristics of the instrument bridge AC R577
Measurement range of the instrument bridge AC R577 Measurement error of inductance Operating Frequency Range  
inductance Q (f = 1 kHz) in the equivalent circuit  
consistent Parallel  
10 -3 10 -2-mH mH
10 -2 10 -1-mH mH
10 -1 mH-1mGn
0,2-5,5
2.5
2-50
- ± (2 +9 × 10 -3 / L)% 800Hz-20000Hz
500Hz-5000Hz
500Hz-5000Hz
 
± (1 +6 × 10 -3 / L)%  
1mGn-10mGn
10mGn-10 2 mH
February 10-March 10 mH mH
March 10-April 10 mH mH
2-50
2-50
2-50
-
20/200
20/200
20/200
-
500Hz-5000Hz
500 Hz, 2500 Hz
500Hz-1000Hz
200Hz-800Hz
 
April 10 mH-1, 1.10 5 mH - - ±2 40Hz-200Hz  
Note:
- When working on the built-in operating frequency is 1000 Hz;
- L - inductance mH;
 
Table 2 Main technical characteristics of the instrument bridge AC R577
Measurement range of the instrument bridge AC R577 Measurement error of inductance Operating Frequency Range  
capacity dielectric loss, rad (at f = 1 kHz) in the equivalent circuit  
consistent Parallel  
MKF-10 -6 10 -4 uF
MKF-10 -4 10 -3 uF
MKF-10 -3 10 -2 uF
10.3.
10 -3 -10 -2
10 -2 -10 -1
-
-
2.10 -2 -1
± (2 +3 x 10 5 / C)% 800Hz-20000Hz
500Hz-5000Hz
500Hz-5000Hz
 
± (1 +2 × 10 -5 / C)%  
MKF-10 -2 10 -1 uF
10 -1, 1 uF uF
1 uF, 10uF
10uF-February 10 uF
2-50
2-50
2-50
-
2.10 -2 -1
2.10 -2 -1
2.10 -2 -1
-
500Hz-5000Hz
500 Hz, 2500 Hz
500Hz-1000Hz
200Hz-800Hz
 
February 10 uF-1, 1.10 3 uF - - ±2 40Hz-200Hz  
Note:
- When working on the built-in operating frequency is 1000 Hz;
- C - the capacity, uF;
 
Table 3: The main technical characteristics of the instrument bridge AC R577
Measuring range Measurement error device bridge AC R577 The voltage at the terminals to enable the measured resistance
DC at a frequency f = 1000 Hz DC on alternating current
0.1 Ohm 1 Ohm
1 ohm, 10 ohm
10 Ohm-10 2 Ohm
February 10 Ohm-10 3 ohm
March 10-10 Ohm 4 Ohm
April 10-May 10 ohm ohm
May 10-June 10 ohm ohm
June 10 ohm-1 1.10 7 W
± (0,02 R ± 0,02)%
± 0,02 R%
± 0,01 R%
± 0,01 R%
± 0,01 R%
± 0,02 R%
± 0,05 R%
± 0,05 R%
-
± 20Hz
± 10Hz
± 10Hz
± 20Hz
-
-
-
10B
10B
10B
20B
20B
20B
250V
250V
-
4B
4B
4B
4B
-
-
-
 
Ambient temperature - 10 º C to 35 º C;
Relative humidity - up to 80% at 30 º C;
Dimensions of the device bridge AC R577 - 420h235h270mm;
Weight - 9kg;
Time to failure - not less than 3000 hours;
The manufacturer guarantees that the quality of the instrument bridge AC R577 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.

Photos R577

R577 (P577) device image.
R577 (P577) device image.
R577 (P577) front view.
R577 (P577) front view.
R577 (P577) rear view.
R577 (P577) rear view.
R577 (P577) overhead view.
R577 (P577) overhead view.