Electrical measuring instruments >> measuring bridges

R5026

90 999 RUB
36 400 UAH
available:
13 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
 
Bridge AC R5026 (P-5026, P 5026, p5026, p-5026, p 5026)
 
Bridge AC R5026 is designed for measuring capacitance and dissipation factor at 50Hz.
 
Technical characteristics of the instrument shops resistance R5026:
 
Temperature - from +10 º C to +35 º C from -10 º C to +40 º C;
Relative humidity - up to 80% to 90% at 25 º C;
Measurement of capacitance and dielectric loss tangent bridge device R5026 AC at high voltage carried by the "direct" scheme (both electrodes measured object isolated from the ground) and "inverted" scheme (one of the electrodes measured object is connected to ground) at low voltage (from internal power supply) - at "direct" scheme;
 
Measurement of capacitance and dielectric loss tangent unit bridge AC R5026
 
Measuring range Allowable main error
C x tgδ x C x tgδ x
10pF-1000pF 1 ∙ 10 -4 rad, 0, 1rad ± (0,5 +100 / C)% ± (0,01 tgδ x +2 ∙ 10 -2)%
100pF-10000pF 1 ∙ 10 -4 rad-1, 0rad ± (0,5 +50 / C)% ± (0,01 tgδ x +1 ∙ 10 -4)%
April 10 pF 2 ∙ 10 4 pF
2 ∙ 10 4 pF 5 pF-10
May 10 pF 6 pF-10 5 ∙ 10 -4 rad-1, 0rad ± 1% ± (0,025 tgδ x +2 ∙ 10 -4)%
100pF-10000pF 5 ∙ 10 -3 rad-1, 0rad ± (2,5 +50 / C)% ± (0,05 tgδ x +3 ∙ 10 -3)%
(10 4 pF 5 pF-10) / (10 5 pF 6 pF-10)
650pF-2 ∙ 10 5 pF 5 ∙ 10 -3 rad 0 1rad ± 2,5%
6500pF 2 ∙ 10 6 pF 5 ∙ 10 -3 rad-1, 0rad
2 ∙ 10 6 pF-5 pF ∙ August 10
 
Measuring range Operating voltage Measurement scheme
C x tgδ x
10pF-1000pF 1 ∙ 10 -4 rad, 0, 1rad 5kV-10kV "Straight" with the F5122 and R5069
100pF-10000pF 1 ∙ 10 -4 rad-1, 0rad 3kV-10kV
April 10 pF 2 ∙ 10 4 pF
2 ∙ 10 4 pF 5 pF-10 3kV-5kV "Direct" from F5122
May 10 pF 6 pF-10 5 ∙ 10 -4 rad-1, 0rad
100pF-10000pF 5 ∙ 10 -3 rad-1, 0rad 3kV-10kV "Direct" and "inverted"
(10 4 pF 5 pF-10) / (10 5 pF 6 pF-10)
650pF-2 ∙ 10 5 pF 5 ∙ 10 -3 rad 0 1rad 0,1 kV "Straight"
6500pF 2 ∙ 10 6 pF 5 ∙ 10 -3 rad-1, 0rad
2 ∙ 10 6 pF-5 pF ∙ August 10
 
Changing the instrument error R5026 ac bridge at a deviation of ambient temperature (in the temperature range) for every 10K - less than half the permissible basic error;
Dimensions - 540h380h280;
Weight - 22kg;
MTBF unit bridge AC R5026 - not less than 5250 hours;
Average life - at least 6 years.

Photos Р5026

R5026 (P5026) device image.
R5026 (P5026) device image.
R5026 (P5026) accessories and spare parts.
R5026 (P5026) accessories and spare parts.
R5026 (P5026) front view.
R5026 (P5026) front view.
R5026 (P5026) side view.
R5026 (P5026) side view.
R5026 (P5026) overhead view.
R5026 (P5026) overhead view.


Яндекс цитирования