Radiometric devices >> uniformity tester of cables and lines

R5-11 Measurer R5-11 line inhomogeneities

R5-11

56 999 RUB
27 360 UAH
available:
2 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Measurer R5-11 line inhomogeneities (R5 11, R511, p5-11, p5 11, p511)

Designed to detect heterogeneity of wave resistance in the cables and power lines and communication in coaxial RF paths, to determine the distance to the fault location, type of damage, measurement of the heterogeneity.
Range of distance to the full scale of 0.1 - 200m.
The maximum resolution of 0,015 m sposobonost
The basic error of distance (time delay) from the end of the range of 2%.
Input impedance of 50 ohms.

Measurer R5-11 line inhomogeneities is designed to detect heterogeneity of the wave resistance (damage) in the cables and power lines and communication in coaxial RF paths, to determine the distance (time delay) to the injury site (heterogeneity), type of damage, measurement of the heterogeneity.
Measurer R5-11 line inhomogeneities, portable meters formed on the semiconductor devices and chips can be used in laboratory and field conditions, not only for measurements on damaged lines, but also for monitoring cables predicting faults in them, measure their lengths balancing from the time delay with a large FITNESS
All appliances R5-11 it is possible to supply from a DC: 12.6 V
The principle of operation of appliances Measurer R5-11line inhomogeneities is based on the method of pulse reflectometry - a modern method for the study of distributed systems, which allows to observe simultaneously all the irregularities in the line and measure the position and characteristics of each of them individually.
The main advantages of this method are the clear presentation of the measurement results, faster measurement time, high sensitivity, the ability to determine the parameters of the elements of a distributed system in ohms, Henry, Farad.
Modern devices such as measurer R5-11 line inhomogeneities meters heterogeneity parameters of transmission lines picosecond range are characterized by high-resolution in distance component units centimeters (for lines with an air-filled).
Dimensions, mm Weight, kg 160X260X430 11,5 (base unit), 0.25 (Generator) 0.65 (mixer)
 
Basic data
 
Range
measurement
of
distance
of
(The entire
scale) m
Maxi-
mum
Allow-
yuschaya
way-
In particular, m
The basic error of
ABILITY measurement
of
distance
of (time-
tion delay)
from the end of range
area,%
Time
Ramp up-
of pe-
sition-
tion characterized
tics,
ns
Sensitivity
ABILITY
The duration of the sensing
ating signal
nals, ms (the pulse shape
ca)
Rin, Ohm
According to the coefficient
fitsien-
that reflected
tion
By overlapping
Vai for damping
From 0.1 m to 200 m 0.015 2 (working conditions) 0.15 1-0.001 - (Differential) 50