Electrical measuring instruments >> transformers industrial >> voltage transformers >> single-phase voltage transformer

NOL.11-6.O5

12 524 RUB
3 910 UAH

Online prices include VAT.

For order is possible effectively delivery of any quantity.
    Do not ground the transformer voltage NOL.11-6.O5 (NOL116O5, NOL.11 6.O5, NOL11-6.O5, NOL11 6.O5, NOL.11-6O5, 6O5 NOL.11, NOL.11-6.05, NOL. 11 6.O5.1)
    Do not ground the transformer voltage NOL.11 6.O5 - designed for use in electrical circuits of AC 50Hz signal to transfer measurement data measurement devices, protection, automation, alarm and control.
    Avoid prolonged operation of transformers, as power, that is, outside the guaranteed accuracy class, with a load does not exceed the capacity.
    Technical characteristics of the instrument do not ground the transformer voltage NOL.11-6.O5:
    Voltage Class - 6 kV;
    Maximum operating voltage instrument transformer napryazheniyaNOL.11-6.O5 - 7.2 kV;
    Rated voltage of the primary winding - 6 000V;
    Rated secondary voltage instrument transformer voltage NOL.11-6.O5 - 100 V or 11 0V;
    Rated power of the secondary winding voltage transformer  NOL.11-6.O5.1:
    - A branch (x-a1) - 100V, 100V;
    - A branch (x-a2) - 127V, 220V;
    Accuracy class of the secondary voltage transformer NOL.11-6.O5:
    - A branch (x-a1) - 3, 3;
    - A branch (x-a2) -, 3;
    Power rating with power factor active-inductive load cosφ = 0,8:
    - A branch (x-a1) - 250 · A, 30 V · A;
    - A branch (x-a2) -, 220 · A;
    Power limit is the accuracy class - 500V · A;
    Maximum permissible continuous primary current - 0.11 A;
    Scheme and winding connection group  instrument voltage transformer NOL.11-6.O5.1 - 1/1-0;
    Rated frequency - 50 Hz;
    Tolerance of the rated transformation ratio on the branch (x-a2) - ± 3%;
    Voltage drop with a triple overload to the maximum power on the branch (x-a2) - not more than 20%;
    General view of the device shown in Figure 1;
    Figure 1: General view of the instrument do not ground the transformer voltage NOL.11-6.O5

 General view of the instrument do not ground the transformer voltage NOL.11-6.O5
 
    Unit weight voltage transformer NOL.11-6.O5 - 16kg;
    The transformers are manufactured in climatic design "Y" and are intended for indoor use in:
    - Height above sea level is not more than 1000m;
    - Ambient temperature with the heat the air inside the switchgear - from -45 ° C to +45 ° C;
    - Relative humidity - 100% at 25 º C;
    - Environment-explosive, without dust, corrosive gases and vapors in concentrations destroying coating metals and insulation;
    - Working position - any;
    - Internal insulation do not ground the transformer voltage NOL.11 6.O5.1 - cast, heat resistance class "B" and flammability class FH (PG) 1;
    - Instruments earthquake resistant when exposed to earthquake intensity 8 points on the MSK-64 at the facility level above ground level up to 70m;
    - Instruments voltage transformer NOL.11-6.O5 comply immunity to electromagnetic interference to influence the magnetic field of industrial frequency;
    - Devices conform to standards of industrial radio Class A, Group 1;
    The manufacturer guarantees that the quality of the instrument do not ground the transformer voltage NOL.11-6.O5 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.

Photos NOL.11-6.O5

Do not ground the transformer voltage NOL.11-6.O5.
Do not ground the transformer voltage NOL.11-6.O5.