Electrical measuring instruments >> transformers industrial >> voltage transformers >> single-phase voltage transformer

NOL-35-III

99 564 RUB
30 822 UAH

Online prices include VAT.

For order is possible effectively delivery of any quantity.

    Do not ground the voltage transformers NOL-35-III (NOL35, NOL 35, NOL-35 UHL1, NOL-35-III)

    Do not ground the voltage transformers NOL-35 is designed for use in electrical circuits, AC 50Hz signal to transfer measurement data measurement devices, protection, automation, alarm and control.
    Avoid prolonged operation of transformers, as power, that is, outside the guaranteed accuracy class, with a load does not exceed the capacity.
    Technical characteristics of the instrument do not ground the voltage transformers NOL-35  
    Voltage Class - 35kV;
    Maximum operating voltage of the device voltage transformer  NOL-35 - 40.5 kV;
    Rated voltage of the primary winding - 35000V;
    Rated secondary voltage instrument transformer voltage NOL-35 - 100V;
    Accuracy classes of primary secondary - 0.2, 0.5, 1, 3;
    Rated power of main secondary winding voltage transformer  NOL-35 NF1 power factor active-inductive load 0.8:
    - In accuracy class 0.2 - 10V · A · A 50V;
    - In accuracy class 0.5 - 75V · A · A 150V;
    - In class 1 - 150V · A · A 300V;
    - In accuracy class 3 - 600 V · A;
    Extreme power is class precision - 1000 V · A;
    Maximum permissible continuous primary current - 0.029 A;
    Scheme and winding connection group  instrument voltage transformer NOL-35 - 1/1-0;
    Rated frequency - 50 Hz;
    Rated short-circuit voltage instrument transformer voltage  NOL-35 NF1 load for accuracy class 0.5 - 0.38%;
    Creepage distance - at least 116cm;
    General view of the device shown in Figure 1;
    Figure 1: General view of the instrument do not ground the voltage transformers NOL-35

General view of the device do not ground the transformer voltage NOL-35

 
    Unit weight  voltage transformer NOL-35-III - 106kg;
    The transformers are manufactured in climatic design "Y" and are intended for indoor use in:
    - Height above sea level is not more than 1000m;
    - Ambient temperature with the heat the air inside the switchgear - from -60 ° C to +55 ° C;
    - Relative humidity - 100% at 25 º C;
    - Environment-explosive, without dust, corrosive gases and vapors in concentrations destroying coating metals and insulation;
    - Working position - vertical;
    - Internal insulation do not ground the voltage transformers NOL-35 NF1 cast, heat resistance class "B" and flammability class FH (PG) 1;
    - Transformers are designed for total mechanical stress from wind speed 40m / s, ice wall thickness of 20mm and ice wires tension of at least 500N (50kgs)
    - Instruments earthquake resistant when exposed to earthquake intensity of 9 points on the MSK-64 at the facility level above ground level up to 70m;
    - Instruments voltage transformer NOL-35-III compliant immunity to electromagnetic interference to influence the magnetic field of industrial frequency;
    - Devices conform to standards of industrial radio Class A, Group 1;
    The manufacturer guarantees that the quality of the instrument voltage transformer nezazemlyaemy NOL-35 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.

Photos: NOL-35-III

Do not ground the transformer voltage NOL-35.
Do not ground the transformer voltage NOL-35.


Яндекс цитирования