M45MY3

9 999 RUB
4 000 UAH
available:
24 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
M45MU3 ammeter, voltmeter M45MU3, M45MU3 milliamp, millivolt M45MU3 (M-45-M-U3, M 45 M U3)
 
M45MU3 ammeter, voltmeter M45MU3, M45MU3 milliamp, millivolt M45MU3 designed to measure current and voltage in DC.
Dimensions - 125h110h55mm.
Accuracy class - 1.0.
Vibration, splash.
 
Technical characteristics of the devices M45MU3 ammeters, voltmeters M45MU3, milliammeter M45MU3, millivoltmeters M45MU3:
 
Accuracy class - 1;
Maximum permissible error of the instrument M45MU3 ammeter, voltmeter M45MU3, M45MU3 milliamp, millivolt M45MU3 all of the scale - less than ± 1%;
The basic error is expressed:
- For units with the zero mark on the edge of the measuring range - a percentage of the final value of the measuring range;
- For units with a zero mark within the range of measurement - as a percentage of the sum of absolute values ​​of finite range;
The final values ​​of the measuring range of devices M45MU3 ammeter, voltmeter M45MU3, M45MU3 milliamp, millivolt M45MU3 listed in Table 1;
 
Table 1: The final values ​​of the measuring range of devices M45MU3 ammeter, voltmeter M45MU3, M45MU3 milliamp, millivolt M45MU3
Instrument name
The final value of the measuring range
Switching on
Millivoltmeter M45MU3
75mV
75mV-0mV-75mV
75mV-150mV-750mV-1500mV
connected
Voltmeter M45MU3
3V
3V-7,5V-15V-30V
3V-15V-150V-300V
3V-30V-300V
3V-150V-450V
15V-150V-450V
30V-75V-150V-300V
150V-300V-450V
150V-300V-600V
75mV-3V-15V-150V
Milliampervoltmetr M45MU3
1,5mA-7,5-150V
Milliammeter M45MU3
7,5mA-15mA-30mA
1,5mA-7,5mA-15mA-30mA
3mA-15mA-75mA-150mA
 
Temperature - from -40 º C to +60 º C;
Relative humidity - 90% ± 3% at 30 º C;
Changing M45MU3 ammeter readings, M45MU3 voltmeter, milliammeter M45MU3, millivolt M45MU3 due to:
- Changing the position of the device from its normal position in any direction does not exceed 30 º ± 1%;
- Changes in air temperature from normal to any temperature within the operating temperature does not exceed ± 0,5% for every 10 º C of temperature change;
- Changes in the external constant homogeneous magnetic field with induction of 0.5 mT in the most unfavorable direction of the magnetic field does not exceed ± 1,5% and the induction of 1.5 mT - does not exceed ± 2%;
Changing M45MU3 ammeter readings, M45MU3 voltmeter, milliammeter M45MU3, millivolt M45MU3 expressed as basic error;
Response time - no more than 4s;
Insulation between the body and insulated from the DC circuits devices M45MU3 ammeter, voltmeter M45MU3, M45MU3 milliamp, millivolt M45MU3 stand for 1 minute test voltage operation, practically sinusoidal frequency of 50 Hz;
RMS voltage should be:
- 2kV - under normal temperature and humidity;
- 1.5 kW - at normal temperature and humidity 95% - only for devices execution OM;
The insulation resistance between the case and isolated dc circuits not less than:
- 40 MW - under normal conditions of temperature and humidity;
- 5 MW - at 60 º C and a relative humidity of 80%;
- 2 M - at 20 º C and a relative humidity of 90% ± 3%;
- 0.5 MW - at 60 º C and a relative humidity of 90% ± 3%;
Dimensions devices M45MU3 ammeter, voltmeter M45MU3, M45MU3 milliamp, millivolt M45MU3 - 125h110x55mm;
Weight - 0.5 kg;
The manufacturer guarantees that the quality of devices M45MU3 ammeter, voltmeter M45MU3, M45MU3 milliamp, millivolt M45MU3 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.

Photos M45MY3

M45MU3 front view (scale).
M45MU3 front view (scale).
M45MU3 side view (casing depth).
M45MU3 side view (casing depth).
M45MU3 rear view.