Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> size 120х120mm

M4264M

1 608 RUB
900 UAH
available:
51 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
M4264M ammeter, voltmeter M4264M, M4264M milliammeter, kiloampermetr M4264M, M4264M kilovoltmeter (M 4264 M, M-4264-M , M4264 M, M4264-M, M 4264M, M-4264M)
 
M4264M ammeter, voltmeter M4264M, M4264M milliammeter, kiloampermetr M4264M, M4264M kilovoltmeter designed to measure DC and AC power.
Dimensions - 120h120mm, cutout in the panel 112h112mm.
Accuracy Class - 1.5, 2.5.
Vibration, shock-proof, vibration resistance.
 
Technical characteristics of the devices M4264M voltmeters, ammeters M4264M, M4264M kilovoltmeters, milliammeter M4264M, M4264M kiloampermetry:
 
Measuring range of current - from 10mkA up to 20A.
To expand the range of measurement devices M4264M ammeter, voltmeter M4264M, M4264M milliammeter, kiloampermetr M4264M, M4264M kilovoltmeter current from 20A to 15kA shunts are used for measuring steady 75mV (manufacture at 60mV, 100mV, 150mV).
Shunts are ordered separately.
Calibrated wires connecting the devices M4264M ammeter, voltmeter M4264M, M4264M milliammeter, kiloampermetr M4264M, M4264M kilovoltmeter with shunts are supplied with equipment (at customer's request).
Measuring range of voltage - 25mV to 600V from.
To expand the range of measurement devices M4264M ammeter, voltmeter M4264M, M4264M milliammeter, kiloampermetr M4264M, M4264M kilovoltmeter voltage from 1kV to 4kV apply additional resistance.
 
Device Type
M4264M
Front dimensions
120h120mm
Cutout in the panel
112h112mm
The length of the scale, at least
94mm
Accuracy class
1.5, 2.5
Weight,
0.35 kg
 
Devices M4264M ammeter, voltmeter M4264M, M4264M milliammeter, kiloampermetr M4264M, M4264M kilovoltmeter - only 1.5 accuracy class
 
M4264M
mA - 0.5 mA, 0.75 mA, 1mA, 3mA, 5mA, 10mA, 15mA, 20mA, 30mA, 50mA, 75mA, 100mA, 150mA, 300mA, 500mA, 600mA
 
 
directly
temperature -40 º C. .. +50 ° C, relative humidity 95% at +35 o C.
Vibration resistance: acceleration 15 m / s 2, frequency 30Hz.
Shock resistance: acceleration 70 m / s 2, frequency 10 ... 50 beats per minute.
Vibration resistance: acceleration of 5m / s 2, frequency 20Hz -
for M4264M
A - 1A, 2A, 3A, 5A, 10A, 20A
A - 30A; 50A, 75A, 100A, 150A, 200A, 300A, 500A, 750A
with an external shunt to 75mV and calibrated wire resistance 0.035 W
kA - 1kA, 1.5 kA 2kA; 3kA; 4kA; 5kA, 6kA, 7.5 kA
A - 200A, 400A, 600A
with an external shunt to 150mV and calibrated wire
kA - 1kA; 2kA; 3kA; 4kA, 6kA; 8kA, 10kA, 15kA, 20kA, 30kA
B - 0.075 B *; 0.15 *, 3B, 7.5 V, 15V, 30V, 50V, 75V, 100V, 150V, 250V, 300V, 400V, 500V, 600V, 750V
 
directly
 
kV - 1 kV, 1.5 kV 3 kV, 10kV, 15kV
with an external resistance added to the nominal current 5mV
* - Equipment M4264M ammeter, voltmeter M4264M, M4264M milliammeter, kiloampermetr M4264M, M4264M kilovoltmeter with calibrated wire resistance 0.035 W;
** - M4264M devices ammeter, voltmeter M4264M, M4264M milliammeter, kiloampermetr M4264M, M4264M kilovoltmeter only from ground level within the measurement range.

Photos M4264M

M4264M front view (scale).
M4264M front view (scale).
M4264M side view (casing depth).
M4264M side view (casing depth).
M4264M rear view (connection).
M4264M rear view (connection).


Яндекс цитирования