Microammeter M4241 (M 4241, M-4241)
 
Microammeter M4241 designed for measuring the current in DC and AC.
Accuracy class - 1.5, 2.5;
Dimensions - 60h60h48mm;
Vibration, shock and vibration resistant.
 
Technical characteristics of the devices microammeter M4241:
 
Accuracy class - 1.5, 2.5;
Maximum permissible error of the instrument microammeter M4241 - ± 1,5% - for instruments of accuracy class 1.5, and ± 2,5% - for instruments of accuracy class 2.5;
Additional error - ± 0,8% - for instruments of accuracy class 1.5, and ± 1,2% - for instruments of accuracy class 2.5;
The length of the instrument scale microammeter M4241 - 46mm;
Failure to return the arrows to zero - 0.7 mm - for units of accuracy class 1.5 and 1.1 mm - for instruments of accuracy class 2.5;
Measurement range - 0mkA-10mkA, 0mkA-20mkA, 0mkA-30MKA, 10mkA-0mkA-10mkA, 20mkA-0mkA-20mkA;
The resistance of the external circuit device microammeter M4241 - more than 50 ohms;
Voltage drop or current full deflection - 200 mV;
The variation of the readings does not exceed the permissible basic error;
In terms of resistance to mechanical stress device microammeter M4241 refers to vibration and impact resistance and stability;
Settling time moving part - 4c;
Operating position of the device - the horizontal and vertical;
Changing readings microammeter M4241 caused deviation of ambient temperature from normal to any (within the operating temperature range) for every 10 K, does not exceed ± 0,8% - for instruments of accuracy class 1.5, and ± 1,2% - for appliances accuracy class 2.5;
Admissible additional instrument error caused by the influence of an external uniform static magnetic field induction of 0.5 mT is ± 0,5%, when exposed to an alternating magnetic field frequency of 100 Hz - is ± 2,5%;
Dimensions of the device microammeter M4241 - 60h60h48mm;
Weight - 0.15 kg;
Mean time to failure of the device microammeter M4241 - no less than 24,000 hours;
Average life - at least 6 years;
The manufacturer guarantees that the quality of the instrument microammeter M4241 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.