Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> size 96x96mm


999 RUB
250 UAH
64 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
    M42272 ammeter, voltmeter M42272, M42272 ammeter, milliammeter M42272, M42272 millivoltmeter, kiloampermetry M42272, M42272 kilovoltmeter
    Also, this device can be called: M-42272, M 42272, m42272, m-42272, m 42272.

    Ammeter, voltmeter, ammeter, milliamp, millivolt, kiloampermetry, kilovoltmeter M42272 - devices-coil system for measuring current or voltage in electrical circuits, DC.
    M42272 devices - with removable scales. Change scale (without opening of the instrument) is a groove in the upper housing.
    Measuring gear units consists of a movable coil (frame) and a cylindrical magnet disposed inside the frame.
    M42272 principle based on the interaction of the magnetic field of the permanent magnet with the electric current passing through the winding frame.
    The devices are characterized by a dial indicator, mounted on the moving part of the cores or banners, uniform scale, a zero mark in or on the edge of the measuring range.

    Technical characteristics of the devices M42272

    Dimensions 96x96x75 mm.
    Scale length - 97 mm.
    Accuracy class 1.5.

    Ranges include devices and methods are shown in Table 1.

    Table 1. Measuring ranges of devices and ways to incorporate M42272.
Measurement range
A way to incorporate
uA - 100uA; 150mkA; 250mkA; 400mkA; 600mkA; 1000mkA
mA - 1 mA, 1 mA, 5 mA, 2 mA, 5 mA, 4 mA, 5 mA, 6 mA, 10mA, 15mA, 20mA, 25mA, 40mA, 50mA, 60mA, 100mA, 150mA, 250mA, 400mA, 600mA
A - 1 A, 1.5 A, 2.5 A, 4A, 6A, 10A, 15A
A - 1A, 1.5A, 2A, 2.5A, 3A, 4A, 5A, 6A, 7.5 A, 10A, 15A, 25A, 40A, 60A, 100A, 150A, 200A, 250A, 400A, 600A
With external shunt on 6MV and calibrated wires with resistance 0.035 Ohm
kA - 1kA, 1.5 kA 2.5 kA 4ka, 6 kA, 10kA, 15kA
A - 1A, 1.5A, 2A, 2.5A, 3A, 4A, 5A, 6A, 7.5 A, 10A, 15A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 500A, 750A;
With external shunt for measuring 75mV and calibrated wires with resistance 0.035 Ohm
kA - 1kA, 1.5 kA 2ka; 3kA; 4ka; 5kA, 6 kA, 7.5 kA
mV - 60mV, 100mV, 150mV, 250mV, 400mV, 600mV
B - 1B, 1,5 V, 2,5 V, 4V, 6V, 10V, 15V, 25V, 40V, 60V, 100V, 150V, 250V, 300V, 400V, 500V, 600V
kV - 1 kV, 1.5 kV, 3 kV, 5 kV, 7.5 kV, 10kV, 15kV
With an external series resistor with a nominal current of 1 mA and 5 mA
    Operating conditions of devices M42272

    Temperature from -30 ° C to +55 ° C.
    Relative humidity 80% at +25 ° C.
    Vibration resistance: maximum acceleration of 5 m / s 2, the frequency of 20Hz.
    Vibration resistance: acceleration of 15 m / s 2, the frequency of 30Hz.
    Shock: acceleration of 70 m / s 2, the frequency of 10-50 beats per minute.
    Weight of the device M42272 - 0.2 kg.
    Mean time to failure of devices - 39,000 hours.
    Average life - 8 years.

Яндекс цитирования