Microammeter M2001/1-M1, M2001/1-M1 ammeter, voltmeter M2001/1-M1, milliammeter M2001/1-M1, kiloampermetr M2001/1-M1, kilovoltmeter M2001/1-M1, voltammeter M2001/1-M1 (M2001/1M1, M-2001/1-M1, M20011-M1)
 
Microammeter M2001/1-M1, M2001/1-M1 ammeter, voltmeter M2001/1-M1, milliammeter M2001/1-M1, kiloampermetr M2001/1-M1, kilovoltmeter M2001/1-M1, voltammeter M2001/1-M1 designed to measuring current and voltage in DC circuits.
Dimensions - 60h60h69, 5mm.
Accuracy class - 2.5.
Resistant to shaking, vibration resistance.
 
Technical characteristics of the devices microammeter M2001/1-M1, M2001/1-M1 ammeters, voltmeters M2001/1-M1, milliammeter M2001/1-M1, kiloampermetry M2001/1-M1, kilovoltmeters M2001/1-M1, voltammeter M2001/1- M1:
 
Designed to measure current and voltage in DC circuits.
Devices used for ambient temperature - from -50 º C to +60 ° C and relative humidity up to 95% (at 35 ° C).
In terms of resistance to mechanical stress microammeter M2001/1-M1 instruments, ammeter M2001/1-M1, M2001/1-M1 voltmeter, milliammeter M2001/1-M1, kiloampermetr M2001/1-M1, kilovoltmeter M2001/1-M1, voltammeter M2001 / 1-M1 are tryaskoprochnym and vibration.
Execution of instruments and the usual tropical.
 
Table 1
End of scale
The internal resistance of not more than, Ohm
The voltage drop is not over, mV
Turning the device
On the scale of one-sided
50mkA
 
 
Direct
100mkA
 
 
150mkA
 
 
200mkA
 
 
300mkA
 
 
500mkA
 
 
1000mkA
 
 
1mA
350 Ohm
-
5mA
25 ohms
-
10mA
10 ohm
-
30mA
3 ohms
-
50mA
-
90mV
100mA
-
90mV
150mA
-
90mV
300mA
-
90mV
500mA
-
90mV
1A
-
90mV
3A
-
90mV
5A
-
90mV
10A
-
90mV
 
 
 
With the shunt:
20A
___
75mV
75SHS-20a
30A
-
75mV
75SHS-30a
50A
-
75mV
75SHS-50a
75A
-
75mV
75SHSM-75a
100A
-
75mV
75SHSM-100a
150 A
-
75mV
75SHSM-150a
200A
-
75mV
75SHSM-200a
300A
-
75mV
75SHSM-300 and
500A
-
75mV
75SHCM-500 a
750A
-
75mV
75SHSM-750A
1500 A
-
75mV
75SHSM-1500A
1.0 kA
-
75mV
75SHSM-1000A
1.5 kA
-
75mV
75SHSM-1500A
4.0 kA
-
75mV
75SHSM-4000A
6.0 kA
-
75mV
75SHSM-6000A
7.5 kA
-
75mV
75SHSM-7500a
 
End of scale
The internal resistance of not more than, Ohm
The voltage drop is not over, mV
Turning the device
On the scale of bilateral
50mkA-0mkA-50mkA
 
 
Direct
100mkA-0mkA-100mkA
 
 
150mkA-0mkA-150mkA
 
 
200mkA-0mkA-200mkA
 
 
300mkA-0mkA-300mkA
 
 
500mkA-0mkA-500mkA
 
 
1000mkA-0mkA-1000mkA
 
 
1mA, 0 mA, 1mA
350 Ohm
-
5mA 5mA, 0 mA,
25 ohms
-
10mA, 0 mA-10 mA
10 ohm
__
30mA, 0 mA-30 mA
3 ohms
-
50mA-50mA, 0 mA
-
90
100mA, 100mA, 0 mA
-
90
150mA, 150mA, 0 mA
-
90
300mA, 300mA, 0 mA
-
90
500mA, 500mA, 0 mA
-
90
1A-0A-1A
-
90
3A-0A-3A
-
90
5A-0A-5A
-
90
10A-0A-10A
-
90
 
 
 
With the shunt:
20A-0A-20A
___
75mV
75SHS-20a
30A-0A-30A
-
75mV
75SHS-30a
50A-0A-50A
-
75mV
75SHS-50a
75A-0A-75A
-
75mV
75SHSM-75a
100A-100A-0s
-
75mV
75SHSM-100a
150A-150A-0s
-
75mV
75SHSM-150a
200A-200A-0s
-
75mV
75SHSM-200a
300A-300A-0s
-
75mV
75SHSM-300A
500A-500A-0s
-
75mV
75SHSM-500A
200A-750A-0s
-
75mV
75SHSM-750A
750A-750A-0s
-
75mV
75SHSM-750A
1kA-0kA-1kA
-
75mV
75SHSM-1000A
1.5 kA-0kA-1, 5kA
-
75mV
75SHSM-1500A
4kA-0kA-4kA
-
75mV
75SHSM-4000A
6kA-0kA-6kA
-
75mV
75SHSM-6000A
7.5-kA 0kA-7, 5kA
-
75mV
75SHSM-7500a
 
@Footnote.@ Shunts calibrated fixed and calibrated wire.
 
Ammeters, milli-and kiloampermetry have the full scale value.
The internal resistance and voltage drop are given in Table. A.
Voltmeters, and kilovoltmeters voltammeter have full scale value.
Current full deflection and the voltage drop in Table. Two.
Accuracy class of devices microammeter M2001/1-M1, M2001/1-M1 ammeter, voltmeter M2001/1-M1, milliammeter M2001/1-M1, kiloampermetr M2001/1-M1, kilovoltmeter M2001/1-M1, voltammeter M2001/1- M1 2.5.
Settling time moving part to 4 seconds.
Working position of the device - the horizontal and vertical.
Scale length - 48mm.
Change M2001/1-M1 microammeter readings, ammeter M2001/1-M1, M2001/1-M1 voltmeter, milliammeter M2001/1-M1, kiloampermetr M2001/1-M1, kilovoltmeter M2001/1-M1, voltammeter M2001/1- M1, due to the deviation of the ambient temperature of -50 º C to +60 º C, does not exceed ± 1,2% for every 10 degrees, under the influence of an external magnetic field of 400 A / m - not more than ± 1,5%; influenced located very close to him the same device, as well as the installation of devices on a ferromagnetic shield - does not exceed ± 10%.
 
Table 2
 
End of scale
Current full deflection
Voltage drop
Turning the device
 
no more, mA
no more, mV
 
On the scale of one-sided
1.5
1.0 mA
-
 
3B
1.0 mA
-
 
7.5 In
1.0 mA
-
 
15V
1.0 mA
-
 
30B
1.0 mA
-
 
50V 75V
1.0 mA 1.0 mA
-
Direct
150V
1.0 mA
-
 
250V
1.0 mA
-
 
300V
1.0 mA
-
 
450V
1.0 mA
-
 
 
 
 
Since the resistance of the DS:
600V
1.0 mA
-
0.6 MW, 1mA
1.0 kV
1.0 mA
-
1.0 MW 1mA
1.5 kV
1.0 mA
-
1.5 MW, 1mA
3.0 kV
1.0 mA
-
30 MW, 1mA
3V/30V
1.0 mA
-
 
V/300V 7.5 15V / 300V
1.0 mA 1.0 mA
-
Direct
30V/300V
1.0 mA
-
 
15V/500mA
5.0 mA
75mV
With an external shunt type of individual P105 and individual extension resistance-type P105
30V/50A
5.0 mA
75mV
With the calibrated steady-state shunt 75SHS-50 and the wires and calibrated with an individual extension resistance-type P105
50V/50A
5.0 mA
75mV
the same
1A/3kV
5.0 mA
75mV
With an external shunt type of individual P105 with an additional shield with a calibrated resistor 0.6 megohms DC, 5mA type P103
On the scale of bilateral
1.5 V-0 V-1, 5V
1.0 mA
-
 
3V-0V-3V 7.5 V-0 V-7, 5B
1.0 mA 1.0 mA
-
 
Direct
15V-0V-15V
1.0 mA
-
 
30V-0V-30V
1.0 mA
-
 
50V-0V-50V
1.0 mA
-
 
73V-0V-75V
1.0 mA
-
 
0V-150V-150V
1.0 mA
-
Direct
0V-250V-250V
1.0 mA
-
 
0V-300V-300V
1.0 mA
-
 
0V-450V-450V
1.0 mA
-
 
 
 
 
Since the resistance of the DS:
0V-500V-600V
1.0 mA
-
0.6 MW, 1mA
1 kV, 1 kV-0kV
1.0 mA
-
1.0 MW, 1mA
1.5 kV-0kV-1, 5kV
1.0 mA
-
1.5 MW, 1mA
3kV-0kV-3kV
1.0 mA
-
3.0 MW, 1mA
@Footnote.@ Resistance shield dobavoch nye calibrated type R102.
Overall dimensions of the voltmeter to the outside dimension of 1.5 V to 450V - 60x60h70mm.
Overall dimensions of the individual incremental resistance and shunt-type P105 - 25,5 x29, 5x31mm, weight 0.02 kg, an additional calibrated resistance type P103 - 210x80x94mm, weight of not more than 0.65 kg of additional resistance-type R102 110x80x94mm, weight unit 0.23 kg, additional calibrated resistance type R102 - no more than 0.37 kg.
Devices microammeter M2001/1-M1, M2001/1-M1 ammeter, voltmeter M2001/1-M1, milliammeter M2001/1-M1, kiloampermetr M2001/1-M1, kilovoltmeter M2001/1-M1, voltammeter M2001/1-M1 are for flush mounting.
The measuring mechanism - the magnetoelectric system, with direct readout pointer. Structurally, the device is designed in the case of thermosetting plastics.
Instruments for the implementation of housing microammeter M2001/1-M1, M2001/1-M1 ammeter, voltmeter M2001/1-M1, milliammeter M2001/1-M1, kiloampermetr M2001/1-M1, kilovoltmeter M2001/1-M1, voltammeter M2001 / 1 -M1 are dust-and splash-proof.
The moving part of the measuring equipment has drill core support.
The minimum probability of failure of equipment for 500 hours of testing at least 0.8 at a confidence probability of 0.8.

Photos: M2001/1-M1

M2001/1-М1 front view (scale).
M2001/1-М1 front view (scale).
M2001/1-М1 side view (casing depth).
M2001/1-М1 side view (casing depth).
M2001/1-М1 rear view (connection).
M2001/1-М1 rear view (connection).


Яндекс цитирования