    Ammeter M1500/1 (M 1500/1, M-1500/1; M1500-1; m1500 / 1; m 1500/1; m-1500/1; m1500-1)

    The device M1500/1 - a product developed for the measurement of currents in DC networks, as well as to measure the current discharge and charge the battery.

    Accuracy class - 1, 1.5.
    Measurement range:
    - 5A - 750A; 1kA - 7.5 kA;
    - A charge 1kA - 10kA;
    - Class 3 kA - 20kA;
    - Rated current shunt 2ka - 20kA.
    Dimensions 100 × 100 × 145mm.

    Specifications M1500/1

    Basic error M1500/1 does not exceed ± 1,5%, and the error of the type of battery ammeter M1500 / 1 does not exceed ± 1%. Settling time is 3 seconds.
    A way to incorporate the limits 5A - 20A - direct on the other limits - with external shunt 75mV.

    Devices M1500/1 suitable for use in the following conditions:

    - Ambient temperature from -40 ° C to +50 ° C;
    - Relative humidity of the air - up to 100%.
    Operate M1500/1 at a temperature of from -50 ° C to +65 ° C and relative humidity up to 100% (at 90 ° C).
    In terms of resistance to mechanical impact devices M1500/1 are impact-resistant, vibration resistance and vibration.