Datasheets and radio parts >> photodiodes

KVANT-1 Kvant-1 photodiode.


For order is possible effectively delivery of any quantity.
Photodiode KVANT-1 (KVANT1, KVANT 1)
Photodiode KVANT-1 is used in metrology, spectrophotometry in the ultraviolet, visible and near infrared spectral regions, colorimetry, photometry and light meter, scientific research.
Product Specifications photodiodes KVANT-1:
The area of the photosensitive element - 100 mm 2;
Mode Products photodiode KVANT-1 - photovoltaic;
The bias voltage - less than 10 mV;
Dark current for each PSEs Usm = 10 mV - less than 3nA;
Field of the spectral sensitivity of the photodiode products KVANT-1 - 0.2 mm-1, 1 mm;
Monochromatic current sensitivity when applying the operating voltage for λ = 0,2 m - not less than 0.08 A / W;
Monochromatic current sensitivity when applying voltage with λ = 0,55 mm - not less than 0.3 A / W;
Silicon photodiode;
Hermetically sealed;
Housing items photodiode KVANT-1 --metal;
The manufacturer guarantees the product quality photodiode KVANT-1 technical requirements specifications, subject to the consumer the terms and conditions of storage, transportation, installation, operation, established specifications and operational documentation.