Control and measuring devices >> ionization chambers

КНК57М Ionization chamber KNK57M.

КНК57М

For order is possible effectively delivery of any quantity.
Ionization chamber KNK57M (CNC-57-M, 57 M CNC, khk57m, KNK-57M, 57M CNC, KNK57-M, M KNK57, khk-57-m, khk 57 m, khk-57m, khk 57m, khk57-m , khk57 m)
 
Ionization chamber KNK57M designed to measure the neutron flux density associated with the compensation gamma radiation for use in systems management and security of nuclear reactors.
 
Technical characteristics of the instrument ionization chamber KNK57M:
 
Own background - 1,0 ∙ 10 -10 A;
Insulation resistance instrument ionization chamber KNK57M:
- CLE - 3,0 ∙ October 11 ohms;
- Increased operating temperature - 1,0 ∙ August 10 ohms;
Absolute value of sensitivity:
- Gamma-rays - no more than 1,3 ∙ 10 -12 ∙ A -1 ∙ R h, max 1,81 ∙ 10 -5 kg;
- For neutrons: current - not less than 0,31 ∙ A ∙ 10 -14 cm 2 ∙ ∙ neutrons with -1;
Power supply unit ionization chamber KNK57M - ± 500V;
Dimensions - 50h50h231mm;
Unit weight ionization chamber KNK57M - 600g.