Control and measuring devices >> ionization chambers

КНК56М Ionization chamber KNK56M.

КНК56М

For order is possible effectively delivery of any quantity.
Ionization chamber KNK56M (CNC-56-M, 56 M CNC, khk56m, KNK-56m, 56m KNK, KNK56-M, M KNK56, khk-56-m, khk 56 m, khk-56m, khk 56m, khk56-m , khk56 m)
 
Ionization chamber KNK56M designed to measure the neutron flux density associated with the compensation gamma radiation for use in systems management and security of nuclear reactors.
 
Technical characteristics of the instrument ionization chamber KNK56M:
 
Own background - 1,0 ∙ 10 -10 A;
Insulation resistance instrument ionization chamber KNK56M:
- CLE - 1,0 ∙  ohms;
- Increased operating temperature - 1,0 ∙ 10 9 ohms;
Capacitance instrument ionization chamber KNK56M - 1300pF;
Absolute value of sensitivity:
- Gamma-rays - no more than 5,0 ∙ 10 -11 ∙ A -1 ∙ R h, max 6,97 ∙ 10 -4 kg;
- For neutrons: current - not less than 4,00 ∙ A ∙ 10 -13 cm 2 ∙ ∙ neutrons with -1;
Power supply unit ionization chamber KNK56M - 500 B - (200V-500V);
Dimensions - 50h50h655mm;
Unit weight ionization chamber KNK56M - 1600g.