Control and measuring devices >> ionization chambers

КНК56 Ionization chamber KNK56.

КНК56

For order is possible effectively delivery of any quantity.
Ionization chamber KNK56 (CLS-56 CLS 56, khk56, khk-56, khk 56)
 
Ionization chamber KNK56 designed to measure the neutron flux density associated with the compensation gamma radiation for use in systems management and security of nuclear reactors.
 
Technical characteristics of the instrument ionization chamber KNK56:
 
Own background - 1,0 ∙ 10 -10 A;
Insulation resistance instrument ionization chamber KNK56:
- CLE - 1,0 ∙ October 11 ohms;
- Increased operating temperature - 1,0 ∙ 10 9 ohms;
Capacitance instrument ionization chamber KNK56 - 1300pF;
Absolute value of sensitivity:
- Gamma-rays - no more than 1,0 ∙ 10 -11 ∙ A -1 ∙ R h, max 1,40 ∙ 10 -4 kg;
- For neutrons: current - not less than 4,00 ∙ A ∙ 10 -13 cm 2 ∙ ∙ neutrons with -1;
Power supply unit ionization chamber KNK56 - 500 B - (200V-500V);
Dimensions - 50h50h655mm;
Unit weight ionization chamber KNK56 - 1600g.