Electrical measuring instruments >> measures and boxes >> capacity

KME-11

21 998 RUB
8 799 UAH
available:
2 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

A measure KME-11 of the low-capacity exemplary (KME 11, KME11)

 

 

Tab. 1
Indices
The value of indicators
2nd category
3rd rank
5. Allowable annual changes in capacity measures,%
   
for the nominal values ​​of capacitance:
   
0,001 pF
± 0,20
± 0,30
0.01    pF
± 0,03
± 0,10
0.05, 0.1, 0.2, 0.3, 0.4, 0.5 and 1 pF
± 0,01
± 0,03
6. Dielectric Loss
   
for measures with nominal values ​​of 1 pF capacitance
   
at a frequency of 1000 Hz, more
5. 10 -5
5. 10 -5
7. Additional error actions caused
   
deviation ambient temperature
   
from normal to any within the operating temperature
 
from 10 to 35 ° C / per 1 ° C change in temperature
   
tours.%, not more -
   
for measures with nominal values ​​of capacitance:
   
0.01 pF
± 0,010
± 0,020
0.05 pF
± 0,003
± 0,006
0.1 and 0.2 pF
± 0,002
± 0,004
0.3, 0.4, 0.5 and 1 pF
± 0,001
± 0,002
8. The maximum operating voltage,
100
100
9. The extended area, kHz
10
10
10. Additional error actions caused
   
frequency deviation from normal to any frequency
   
adjacent to the work area,%, not more than -
   
for measures with nominal values ​​of capacitance:
   
0,001 pF
± 0,30
± 0,50
0.01    pF
± 0, 05
± 0,20
0.05, 0.1, 0.2, 0.3, 0.4, 0.5, 1 pF
± o, 0
± 0,05
Note. With the release of the production plant manufacturer    guarantees that the measures of the accuracy class.
 
1.3.2. Normal climate conditions in the operation of measures are:
Ambient temperature, ° C;
measures for 2-th discharge ............ 20 ± 2;
measures for the third discharge ............ 20 ± 5;
Relative humidity,% ........ 65 ± 15;
atmospheric pressure, mmHg. ........... 750 ± 30
/ 10 of 5 ±. 4 10 3 Pa /.
1.3.3. Capacitance change measures changes caused by voltage from 50 to 100, does not exceed,%
measures for 2nd class - / 0.001 + (2. 10 -4 / C Rated.) /
measures for the third category - / + 0.005 (5. 10 -4 / C Rated.) /
Note: rated - numerical capacitance value, expressed in pF.
1.3.4. The insulation resistance between the electrodes and measures between any of the electrodes and the body is not less than 500 megohms.
1.3.5. Partial capacity measures shall not exceed:
between the inner electrode and the housing 45 pF;
between the external electrode and the housing. 90 pF.
1.3.6. Dimensions measures:
body diameter in mm ............. 76;
height, mm, no more ............ 146.
1.3.7. Weight of one measure, kg, not more than ........ 1.1.

Photos КМЕ-11

KME-11 device image.
KME-11 device image.
KME-11 delivery set.
KME-11 delivery set.
KME-11 accessories and spare parts.
KME-11 accessories and spare parts.
KME-11 front view.
KME-11 front view.
KME-11 overhead view.
KME-11 overhead view.
KME-11 bottom view.
KME-11 bottom view.


Яндекс цитирования