GL 1122 Gas analyzer

Also, this device can be called: GL1122, GL-1122.

GL 1122 analyzer - single-beam two-channel analyzer - designed to determine hydrocarbons in the exhaust gases during the research work on the final design of automotive spark-ignition engines. The operation of the device is a method of direct absorption of infrared radiation with the gas.

Scope of application: at SRI, in factories and other organizations associated with the development, manufacture, repair and adjustment of automotive spark-ignition engines.

Specifications GL 1122:

Accuracy class - 5/0,5.

The range of measured concentrations - 0,01·104 million-1 to 0,5·104 million-1.

Nominal unit price of the least significant digit code - 0,01·104 million-1 volume fraction.

Accuracy - ±(5+0,5 (Sk/S-1))%, where:

Ck - the upper limit of the measuring range (104 million-1 volume);

C - the measured concentration (104 million-1 volume).

Changes in parameters of gas analyzers - not more than 0,5·±(5+0,5 (Sk/S-1)).

Response time - less than 5 seconds.

Wavelengths GL 1122:

- Working - 3,4 microns;

- Supporting - 3,9 microns.

The presence of optical calibration (sensitivity control analyzer while purging gas path ambient air without the use of a control gas mixture).

Having built a digital indicator device to output the results of analysis.

Having an external analog recording instruments (scale - from 0 mV to 100 mV).

Availability of digital printer device.

Operating position - horizontal.

Continuous operation - 8 hours.

Dimensions - no more than 470×340×165 mm.

Weight - 10 kg.

Operating conditions GL 1122:

The ambient air temperature - 10° C to 35° C.

Relative humidity at 25° C - 80%.

Atmospheric pressure - from 86,6 kPa to 106,7 kPa (650 mm hg to 800 mm hg).

Voltage - 216,7 V to 242 V.

Frequency - 50±1 Hz.

Power consumption - no more than 60 V·A.

Warm-up time analyzers devices - no more than 30 minutes.

Tolerance horizontal operating position - ± 20°.

Production of vibration:

- Amplitude - not more than 0,1 mm;

- Frequency - up to 25 Hz.

Environment - non-aggressive, non-explosive.

Tensions external constant homogeneous magnetic field - up to 400 A/m.

Intensity factor operation - no more than 0,24.

The assay mixture GL 1122:

Temperature:

- Connection "sample inlet" - no more than 50° C;

- Inlet probozabornik - 200° C.

Fuel - 5±1,5·10-5 m3/s.

Composition and concentration of the mixture being analyzed:

- Hydrocarbons, - from 0% to 0,5·10-1 million-1%;

- Carbon monoxide - from 0% to 10%;

- Carbon dioxide - from 0% to 15%;

- Nitrogen oxide - from 0% to 0,8%;

- Nitrogen - up to 100%;

- Oxygen - from 0% to 20%;

- Hydrogen, - from 0% to 5%;

- Carbon black - 0 mg/m3 to 0,0002 mg/m3;

- Water - from 0 mg/m3 to 0,015 mg/m3.